Friedrich CP15G10B. EP08G11B Specification Sheet

SPECIFICATIONS
Model UPC Cooling Btu
Chill® (Cool Only)
Chill® Series Excellent efciency with low sound levels for carefree cooling.
Estimated
Heating
Btu
Volts
Rated
Cooling
Amps
Watts
Heating
Amps
Heating
Watts EER CEER
Yearly
Energy
Cost
Moisture
Removal-
Pints/HR Refrigerant CFM
Net Wt.
lbs.
Ship
Wt.
lbs. Sleeve
CP05G10B 724587431728 5200 115 4.3 460 11. 3 11. 0 $42 1. 5 R410A 140
CP06G10B 724587432824 6000 115 4.6 490 12.2 12.1 $44 1. 8 R410A 200
CP08G10B 724587432831 8000 115 6.2 660 12.1 12.0 $60 2.2 R32 250
CP10G10B 724587432848 10000 115 7. 7 820 12.2 12.0 $74 3.0 R32 300
CP12G10B 724587432855 12000 115 9.3 990 12.1 12.0 $89 3.3 R32 330
CP15G10B 724587432862 15500 115 11. 9 1300 11. 9 11. 8 $117 4.0 R32 400
CP18G30B 724587432879 19000/18600 230/208 7.4/8.0 1590/1560 11.9/11.9 11.8/11.8 $138 5.5 R32 520
CP24G30B 724587432886 24000/23500 230/208 11.4/10.6 2260/2310 10.4/10.3 10.3/10.3 $209 6.8 R32 590
®
+ (Electric Heat)
Chill
EP08G11B 724587431735 7500 3850 115 6.3 670 11. 0 1260 11. 2 11. 0 $61 2.1 R410A 250
EP12G33B 724587431742 12000/11500 11200/9200 230/208 4.8/5.1 1060/1010 14.0/15.3 3500/2900 11.3/11.3 11.2/11.2 $96 3.3 R410A 265
EP18G33B 724587431759 18000/17500 12000/9800 230/208 7.2/7.8 1600/1560 16.0/15.0 3670/3100 11.2/11.2 11.1/11.1 $144 5.5 R410A 430
EP24G33B 724587431766 23000/22500 12000/9800 230/208 10.6/11.5 2340/2290 16.0/15.0 3670/3100 9.8/9.8 9.8/9.8 $211 6.5 R410A 560
46 50 P1
62 71
63 72
75 85
83 93
117 132 P8
132 147
137 152
79 85 P6
87 93 P7
136 150
146 160
P6
P7
P9
P9
SLEEVES / DIMENSIONS
CIRCUIT RATING/ BREAKER
Depth
with Front
Width
18
½"
3
5
/8
20
/8
"
Inches
15" 5"
7
/8
21
¾”
7
/8
3
/8
Sleeve
Height Inches
P1† 12"
P6 14” 18
P7 15" 23
P8 16
P9 16
Inches
7
/8
26" 26
7
/8
26" 30
* Minimum extensions when mounted in a window.
** Minimum widths achieved using one side curtain assembly as opposed to both in a standard installation.
Sleeve P1 does not have In- wall hole dimensions, as these units are xed chassis and should not be installed In-wall.
Circuit Rating
Model
CP05G10B 125V - 15A 5 -15P 6 1/ 2
CP06G10B, CP08G10B, CP10G10B, CP12G10B a nd CP15G10B. EP0 8G11B.
CP18G30B 250V - 15A 6 - 15P 4 1/2
CP24G30B. EP12G33B, EP18G33B and EP24G33B.
Chill+ Electric Heat heating information indicates electric heat strip performance.
®
As an ENERGY STAR
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR® models meet the ENERGY STAR® guidelines for
energy efciency.
The consumer, through the AHAM Room Air Conditioner Certi cation Program, can be cert ain that the AHAM Certication Seal accurately states the unit’s cooling and heating capacity rating, the amperes and the energy efciency ratio.
EER is the unit ’s Energy Efciency Ratio; CEER is the unit’s Combined Energy Efciency Ratio.
Your energy costs will depend on your utility rates and use. The estimated energy cost is based on a electricit y cost of $ .12 per kWh. For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
Breaker or
T-D Fuse
125V - 15A 5- 15P 6
250V - 20A 6 - 20P 4
Shell Depth
to Louvers
Inches
8
10
10
8
1
¾"
/8
1
/4
1
/4
"
(NEMA#)
Minimum
Extension
Into Room*
Inches
3
½"
4
½"
4
½"
5
½"
5
½"
Plug Face
Minimum
Extension
Outside * Inches
10
¾"
11" 20
Window Width
Inches
Minimum** Maximum Height Width
1
20
/8
36" NOT FOR THRU-WALL 15 1/4” 22 1/4” 17 1/2”
1
/8
36" 14
12” 25 ¼” 39" 15 ¼" 23
5
16
/8
"
26
½
"
19
½"
Power Cord
Length (ft.)
26 ½"
Wall Outlet
Appearance
42" 17
42" 17
Front
In-wall Installation
Finished Hole Inches
Max. D epth
1
7
/8
” 18
/8
7 ½" 17
7
/8
8" 18 3/4” 26 3/4” 23 7/8”
1
/8
” 26 ¼" 9 " 21 1/2” 29 1/2” 29”
1
/8
” 26 ¼" 9 “ 21 1/2” 33” 28 7/8”
Carton Dimensions
Inches
Height Width Depth
7
/8
22 3/4” 22”
Sleeve Dimensions Drawing
(C)
(B)
SIDE VIEW
Cooling Sizing Guide
Area to be conditioned in sq. ft.
100 - 150 5000
150 - 250 6000
250 - 300 7000
300 - 350 8000
350 - 400 9000
400 - 450 10000
450 - 550 12000
550 - 700 14000
700 - 1000 18000
1000 - 1200 21000
1200 - 1400 23000
1400 - 1500 24000
1500 - 2000 30000
2000 - 2500 34000
Based on normal room insulation, average number of sun exposed windows and two person occupancy.
1. If heavily shaded, reduce cooling Btus required by 10%
2. If very sunny, increase cooling Btus required by 10%
3. Add 500 Btus per person over 2
people
4. Add 4,000 Btus if the area is a
kitchen
Approximate Cooling Btu
Required
LIMITED WARRANTY
Loading...