Friedrich Cp12, Cp10 Service Manual

Timer
Mode
Fan Only
Fan
Speed
0
F
0n/0ff
Cool
hr
®
Money Saver
Dry
Auto
Swing
Temp
201
CP
10
CP12
Timer
0
F
Mode
0n/0ff
Cool
Fan Only
hr
Dry
Money Saver
®
Auto
Fan
Power
Swing
Speed
Temp
7
Congratulations! Thank you for choosing Friedrich.
Your Friedrich unit is designed for maximum comfort and quietness.
Table of Contents
Introduction ..................................................................................2
Safety Precautions.......................................................................3
How to operate your Friedrich ...................................................5
Adjusting the Air Flow Direction.................................................6
Care and Maintenance .................................................................7
Hardware Location.......................................................................8
Installation Instructions
..........................................................
9
Troubleshooting Tips .................................................................17
Warranty ......................................................................................18
2
Introduction
115V~ 230V~
Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Before Operating Your Unit
Make sure the wiring is adequate foryour unit.
If you have fuses, they should be of the time delay type. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in figure 1.
DO NOT use an extension cord.
The cord provided will carry the proper amount of electrical power to the unit; an extension cord will not.
Make sure that the receptacle is compatible with the wall plug provided.
This insures proper grounding. If you have a two-prong receptacle you will need to have the circuit replaced by a certified electrician with a grounded circuit that meets all national and local codes and ordinances. You must use the three-prong plug furnished with the air conditioner.
CIRCUIT
MODEL
TIME DELAY
AMP VOLT
CP10 CP12
15
N OT E !
Aluminum house wiring may pose special problems. Consult a qualified electrician.
RATING OR
PLUG FACE
FUSE
NEMA NO.
125
5-15P
Figure 1
H
S I
L G
N E
For the Best Cooling Performance and Energy Efficiency
Keep the filter clean
Make sure that your air conditioner is always in top performing condition by cleaning the filter regularly. Instructions for removing and cleaning the filter can be found on page 7.
Provide good air flow
Make sure that the airflow to and from the unit is clear. Your air conditioner puts the air out at the side of the unit, and takes in air at the left. Airflow is critical for good operation. It is just as important on the outside of the building that the airflow around the unit exterior is not blocked.
Unit Placement
If your air conditioner can be placed in a window or a wall that is shaded by a tree or another building, the unit will operate even more efficiently. Using drapes or blinds on the sunny side of the dwelling will also add to your unit's efficiency.
Insulation
Good insulation will be a big help in maintaining desirable comfort levels. Doors should have weather stripping. Be sure to caulk around doors and windows.
WARNING
Safety Precautions
To prevent injury and property damage, follow these instructions.
Incorrect operation due to ignoring instructions can cause harm or damage. The seriousness is classified by the following indications.
WARNING This symbol indicates the possibility of death or serious injury.
CAUTION
This symbol indicates the possibility of injury or damage to properties only.
Meanings of symbols used in this manual are as shown below.
Never Do This
Always Do This
Plug in the power plug properly.
• Otherwise, it will cause electric shock or fire due to heat generation.
Do not operate or stop the unit by inserting or pulling out the power plug.
• It will cause electric shock or fire due to heat generation.
Do not damage or use an unspecified power cord.
• It will cause electric shock or fire.
If the power cord is damaged, it must be replaced by the manufacturer or a Friedrich-certified service agent.
Do not modify power cord length.
• It will cause electric shock or fire due to heat generation.
Do not operate with wet hands or in damp environment.
• It will cause electric shock.
Do not direct air flow directly at room occupants.
This could lead to health problems
.
3
Mode
Fan Only
Fan
Speed
4
3
Cool
Dry
5
Timer
0n/0ff
Money Saver
Temp
7
Ai r
Po wer
P urif ier
1
0
F
Auto
Swing
hr
Power
®
5
6
6
2
1
Ti mer
Auto
Swing
Tem p
Fa n S pe ed
Mod e
A
S wing
2
4
3
dry operation.
(dehumidify operation)
6. AUTO SWING
This button can automatically control the air flow direction.
7
To receive the signal from remote controller.
Loading...
+ 13 hidden pages