Friedrich CP10E10 User Manual

Room Air Conditioner
Service and Parts
Manual
CP10 CP12 SVC PARTS 2008 (07/08)
Timer
0
F
Mode
ff
0n/
0
Fan Only
Cool
hr
Dry
®
Money Saver
Auto
Fan
Speed
Swing
Temp
CP10E10 CP12E10
2 Room Air Conditioner
Air Conditioner Service Manual
TABLE OF CONTENTS
Safety Precautions..........................................................................................................................................3
Dimensions .....................................................................................................................................................6
Outside Dimensions ...................................................................................................................................6
Product Specifications ..................................................................................................................................7
Operation ...................................................................................................................................................... 8
How to Operate Your Friedrich CP........................................................................................................... 9
Disassembly .................................................................................................................................................. 10
Mechanical Parts...................................................................................................................................... 10
Air Handling Parts ...................................................................................................................................11
Electrical Parts .........................................................................................................................................12
Refrigerating Cycle...................................................................................................................................13
Schematic Diagram.......................................................................................................................................16
Wiring Diagram.........................................................................................................................................16
Electronic Control Device.........................................................................................................................17
Components Location(For Main P.W.B ASM)...........................................................................................18
Troubleshooting Guide.................................................................................................................................19
Piping System ........................................................................................................................................19
Troubleshooting Guide .............................................................................................................................20
Exploded View ..............................................................................................................................................28
Replacement Parts List ................................................................................................................................29
Safety Precautions
CAUTION
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring instructions will cause harm or damage. The seriousness
is classified by the following indications.
WARNING
Meanings of symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property only.
Be sure not to do.
Be sure to follow the instruction.
WARNING
Always install the expansion panel(s).
• Improper assembly or installation may cause incorrect operation, including injury, fire, and
electric shock hazards.
Do not place the power cord near a heater.
• It may cause fire and electric shock.
Do not use the power cord near flammable gas or combustibles such as gasoline, benzene, thinner, etc.
• It may cause explosion or fire.
Do not disassemble or modify products.
• It may cause failure and electric shock.
Service Manual 3
Safety Precautions
Plug in the power plug properly.
• Otherwise, it will cause electric shock or fire.
Do not modify power corDo not modify poDo not modify po dwer cor
Do not modify po length.
Do not operate or stop the unit by inserting or pulling out the power plug.
• It will cause electric shock or fire.
Use the air conditioner on a single outlet circuit.(see page 7.) Do not share the outlet with other appliances.
Do not damage or use an unspecified power cord.
• It will cause electric shock or fire.
Always plug into a grounded outlet.
• •• It will cause electr ic shoc k or fire.
Ventilate before operating air conditionerwhen gas goes out.
It may cause explosion, fire, and burn.
It will cause electric shock or fire.
Do not use the socket if it is loose or damaged.
It may cause fire and electric shock.
• No •• grounding may cause electric shock.
Do not operate with wet hands or in damp environment.
• It will cause electric shock.
4 Room Air Conditioner
Service Manual 5
Safety Precautions
If water enters the product, turn off the the power switch of the main body of appliance. Contact service center after taking the power­plug out from the socket.
• It will cause electric shock or failure of machine.
CAUTION
Never touch the metal parts of the unit when removing the filter.
Do not clean the air conditioner with water.
• Water may enter the unit and degrade the insulation. It may cause an electric shock.
Do not block the inlet or outlet.
They are sharp and may cause injury.
••
Ensure that the outer caseis not damaged by age orwear.
Leaving it damaged couldresult in the air conditioner falling out of the window, creating a safety hazard.
It may cause failure of appliance or
• performance deteriorate.
Be cautious not to touch the sharp edges
when installing.
It may cause injury.
Sharp edges
6 Room Air Conditioner
Dimensions
Dimensions
Outside Dimensions
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that could cause harm to the air conditioner.
This symbol indicates special notes.
NOTICE
Symbols Used in this Manual
470(18 1/2")525(20 11/16")
/8")
7
353(13
Product Specifications
Product Specifications
Product SpecificationsProduct Specifications
Specfications
MODELS
ITEMS
POWER SUPPLY
COOLING CAPACITY (Btu/h)
INPUT (W)
RUNNING CURRENT (A)
.
E.E.R (BTU/W.h)
OPERATING
CONDITION
REFRIGERANT (R-22) CHARGE
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN/COOLING
FAN MOTOR
OPERATION CONTROL
INDOOR ( C)
OUTDOOR ( C)
.
C)
CP10E10
CP12E10
, 115, 60Hz
10,000
920
8.5
12,000
1,110
1
0.2
10.8
26.7(DB)* 19.4(WB)**
35(DB)* 23.9(WB)**
490g(17.3oz)
505g(17.8oz)
Ø9.52, 2ROW 13STACKS
Ø7.0, 2ROW 17STACKS
.0..0
.0
TURBO FAN
PROPELLER TYPE FAN WITH SLINGER RING
3/3
6 POLES
REMOTE CONTROLLER
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
PROTECTOR
POWER CORD
DRAIN SYSTEM
OUTSIDE DIMENSION
(W x H x D)
H x
* DB:Dry Bulb **
WB:Wet Bulb
COMPRESSOR
FAN MOTOR
(inch)
(mm)
THERMISTOR
HORIZONTAL LOUVER (UP & DOWN), AUTOSWING LOUVER (RIGHT&LEFT)
SLIDE IN-OUT CHASSIS
OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
3 WIRE WITH GROUNDING
ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN PIPE OR SPLASHED BY FAN SLINGER
23
5/8
x14
31/32
x22
5/16
380 x 600 x 555
Service Manual
Ser 7
Ser
Operation
Location and Function of Controls
• DESIGNED FOR COOLING ONLY
• POWERFUL AND INCREDIBLE COOLING
• TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE
• BUILT-IN ADJUSTABLE THERMOSTAT
• WASHABLE ONE-TOUCH FILTER
• COMPACT SIZE
Service Manual 8
Operation
Mode
9 Room Air Conditioner
Fan Only
Fan
Speed
4
3
Cool
Dry
5
Timer
0n/0ff
Money Saver
Temp
7
Ai r
Po wer
P urif ier
1
0
F
Auto
Swing
hr
Power
®
5
6
6
2
1
Ti mer
Auto
Swing
Tem p
Fa n S pe ed
Mod e
A
S wing
2
4
3
6. AUTO SWING
This button can automatically control the air flow direction(left+right).
7
Loading...