Friedrich CP08G10B User Manual

0
F
hr
Fan
Speed
Timer 0n/0ff
Auto
Swing
CoolMoney
Fan
Saver
Only
®
Temp
Dry
Power
Mode
230 115
93011011
CP18 CP15
CP24
0
F
hr
Speed
Auto
Swing
Fan
CoolMoney
Saver
Only
®
Temp
Dry
Timer
Power
Mode
0n/0ff
16
Satefy
18
For inner cleaning, contact an Authorized Service Center or a dealer. Do not use harsh detergent that causes corrosion or damage on the unit.
Harsh detergent may also cause failure of product, fire, or electronic shock.
6
7
8
6
7
3 5
2
4
5
3
1
2
4. CHECK FILTER & FILTER RESET
Check Filter: Your ‘Check Filter’ LED will light up after approximately 250 hours of operation, notifying you that your filter needs to be cleaned.
Filter Reset: press ‘Temp ∨∧’ together to turn off ‘Check Filter’ light.
*Filter Reset must be done from unit control panel, not remote control
MoneySaver: The fan will stop when the compressor stops cooling. The fan will turn on approximately every 3 minutes to sample to room air and determine if more cooling is needed. Cool: fan runs continually for normal cooling operation Fan Only: Fan-only operation
*MoneySaver has it’s own button on your remote control
*Timer Clear: On remote control, ‘Timer Clear’ button will cancel the timer setting
8
6. OPERATION MODE SELECTOR
Push the ‘Mode’ button to rotate between
MoneySaver → Cool → Fan → Dry modes.
(select Dry mode for dry/dehumidifier operation)
41
18
41
8
26
FOAM­HEATPROOF
(2)
(Adhesive-Backed)
Left frame curtain
Bottom guide(2)
Window locking bracket
bracket
Sill
(2)
Support bracket(2)
Foam strip (Plain-Back)
Foam-PE
(2)
(Adhesive-Backed)
Drain joint pipe
Right frame curtain
Type A (11)
Type B (7)
Type C (5) Type D (2)
Carriage Bolt (2) Lock Nut (4)
3.
and bottom
of window frame.
3
Bottom
4
4a. Make sure the pins on the bottom frame guide are facing the back of the unit.(Fig.4-1)
4b. Align both pins to the slotted areas under the cabinet.(Fig.4-2,Fig.4-3)
4c. Push upward fully to insert pins into slotted areas and secure frame guide.(Fig.4-4)
4
4
10
Front
Bottom
Front Front
Bottom View
Fig.4-2Fig.4-1 Fig.4-3
Fig.4-4
4
1. Open the window. Mark a line on the center of
NOTICE
the window stool between the side window stop moldings. Loosely attach the sill bracket to the support bracket using the carriage bolt and the lock nut.
Sill Bracket
Carriage Bolt (M-Screw)
Support Bracket
Lock nut
Fig. 5
2. Attach the sill bracket to the window sill using the screws (Type B). Carefully place the cabinet on the window stool and align the center mark on the bottom front with the center line marked window stool.
3. Using the M-screw and the lock nut, attach the support bracket to the cabinet track hole. Use the first track hole after the sill bracket on the outer edge of the window sill. Tighten the carriage bolt and the lock nut. Be sure the cabinet slants outward.
Do not drill a hole in the bottom pan. The unit is designed to operate with approximately 1/2" of water in bottom pan.
4. Pull the bottom window sash down behind the Top retainer bar until they meet.
1. Do not pull the window sash down so tightly that the movement of F
rame curtain is restricted. Attach the cabinet to the window stool by driving the screws (Type B) through the cabinet into window stool.
2.The cabinet should be installed with a very slight tilt downward toward the outside.
Cabinet Track hole
Support Bracket
Carriage bolt and lock nut
Top retainer bar
Window sash
Foam-PE
Cabinet
Frame curtain
Top retainer bar
Foam-PE
Machine screw(Type D) and lock nut
Outer edge of window sill
Screw(Type B)
Sill bracket
Front angle
Window stool
Fig. 6
Fig. 7
Fig. 8
Sash track
13
Screw(Type B)
Front Angle
Fig. 9
3.
Pull each Frame curtain fully to each window sash track, and pull the bottom window sash down behind the Top retainer bar until it meets.
4.
Attach each Frame curtain the window sash by using screws (Type C.) (See Fig. 10)
5.
Slide the unit into the cabinet.(See Fig. 11)
For security purpose, reinstall screws(Type A) at cabinet's sides.
Cut the Foam-strip to the proper length and insert
6. between the upper window sash and the lower window sash.(See Fig. 12)
7.
Attach the Window locking bracket with a screw (Type C.) (See Fig. 13)
Screw
Screw(Type C)
Power Cord
Screw (Type A)
Foam-Strip
Window locking bracket
ENGLISH
Fig. 10
Fig. 11
Fig. 12
Attach the front grille to the cabinet by inserting the
8.
tabs on the grille into the tabs on the front of the cabinet. Push the grille in until it snaps into place.(See Fig.14)
9.
Lift the inlet grille and secure it with a screw (Type A) through the front grille.(See Fig. 14)
Cut the adhesive-backed Foam-Heatproofs
10. to the Guide Panel size.
Remove the backing from the Foam-Heatproofs and attach the Foam-Heatproofs to Guide Panel.(See Fig. 15)
Foam-Heatproof improves the cooling capability of the unit.
Window installation of room air conditioner is now
11. completed. See ELECTRICAL DATA for attaching power cord to electrical outlet.
Fig. 13
Fig. 14
Fig. 15
14
15
16
10001 Reunion Place, Suite 500
San Antonio, TX 78216
800.541.6645
www.friedrich.com
date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service. Any additional labor cost for removing inaccessible units and/or charges for mileage related to travel by a Service Agency that exceeds 25 miles one way will be the responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within twelve months from the date of the original purchase.
coil, evaporator coil, reversing valve, check valve, capillary, filter drier, and all interconnecting tubing) supplied by FRIEDRICH in your Room Air Conditioner fails because of a defect in workmanship or material within sixty months from date of purchase, FRIEDRICH will pay a labor allowance and parts necessary to repair the Sealed Refrigeration System; not pay the cost of diagnosis of the problem, removal, freight charges, and transportation of the air conditioner to and from the Service Agency, and the reinstallation charges associated with repair of the Sealed Refrigeration System. All such cost will be the sole responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within sixty months from the date of the original purchase.
of Columbia, and Canada. This warranty is not applicable to:
1. Air filters, fuses, batteries and the front grille removal tool.
2. Products on which the model and serial numbers have been removed.
3. Products which have defects or damage which results from improper installation, wiring, electrical current
to: Friedrich Air Conditioning Co.,ATTN:Warranty Registration,10001 Reunion Place,Ste.500,San Antonio,TX 78216.
If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from
If the Sealed Refrigeration System (defined for this purpose as the compressor, condenser
FRIEDRICH will
This warranty is applicable only to units retained within the Fifty States of the U.S.A., District
characteristics, or maintenance; or caused by accident, misuse or abuse, fire, flood, alterations and/or misapplication of the product and/or units installed in a corrosive atmosphere, default or delay in performance caused by war, government restrictions or restraints, strikes, material shortages beyond the control of FRIEDRICH, or acts of God.
Service will be provided by the
in your area. They are listed in the Yellow Pages. If assistance is required in obtaining warranty performance, write
1. Repair of the unit
2. A refund to the customer for the prorated value of the unit based upon the remaining warranty period of the unit.
consequential or incidental damages, so the foregoing exclusions and limitations may not apply to you.
All service calls for explaining the operation of this product will be the sole responsibility of the consumer. All warranty service must be provided by an
repairs being made.
3. Providing a replacement unit of equal value
Some states do not allow limitations on how long an implied warranty lasts, or do not allow the limitation or exclusion of
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Owner must provide proof of purchase in order to receive any warranty related services.
, unless authorized by FRIEDRICH prior to
17
(11-10)
WARNING
1.Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
2.The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
3.Do not pierce or burn. Be aware that refrigerants may not contain an odor.
This unit contains flammable refrigerant and has special safety precautions not normally associated
with older units. Please follow all precautions and advisories.
1. Use caution while handling and prevent damage to unit.Do not put any holes into product for any reason, this can cause damage to product and prevent unit from cooling.
2. Maintenance and cleaning of unit should be performedby trained personnel. Failure to properly
clean unit can result in damage to the refrigeration system and or the electrical system.
3. Make certain that all the air circulation/ventilation openings are free from obstruction.
4. Service should only be performed by technicains properly trained and certified in the use of flammable
refrigerants. Any service performed by unauthorized servicers/individuals will void all warranties.
5. When storing the appliance, do not put in a room with any open flame appliances, such as gas water
heaters or furnaces. Also keep away from electric heaters. Damaged units should be repaired before storage.
18
Loading...