Friedrich CP08E10, CP06E10 User Manual 2

Room Air Conditioner
Service and Parts
Manual
CP06 CP08 SVC PARTS 2008(07/08)
0
Power
Mode
Timer 0n/0ff
Fan
Speed
Temp
CoolMoney
Saver
®
Fan Only
Dry
hr
Auto
Swing
www.sylvane.com 1-800-934-9194
CP08E10 CP06E10
2 Room Air Conditioner
Air Conditioner Service Manual
TABLE OF CONTENTS
Safety Precautions..........................................................................................................................................3
Dimensions .....................................................................................................................................................6
Outside Dimensions ...................................................................................................................................6
Product Specifications ..................................................................................................................................7
Operation ...................................................................................................................................................... 8
How to Operate Your Friedrich CP........................................................................................................... 9
Disassembly ..................................................................................................................................................10
Mechanical Parts..................................................................................................................................... 10
AirH andling Parts ...................................................................................................................................11
Electrical Parts .........................................................................................................................................12
Refrigerating Cycle...................................................................................................................................13
Schematic Diagram.......................................................................................................................................16
Wiring Diagram.........................................................................................................................................16
Electronic Control Device.........................................................................................................................17
Components Location(For Main P.W.B ASM)...........................................................................................18
Troubleshooting Guide.................................................................................................................................19
Piping System ........................................................................................................................................19
Troubleshooting Guide .............................................................................................................................20
Exploded View ..............................................................................................................................................28
Replacement Parts List ................................................................................................................................29
www.sylvane.com 1-800-934-9194
CAUTION
www.sylvane.com 1-800-934-9194
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring instructions will cause harm or damage. The seriousness
is classified by the following indications.
Safety Precautions
WARNING
Meanings of symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property only.
Be sure not to do.
Be sure to follow the instruction.
WARNING
Always install the expansion panel(s).
• Improper assembly or installation may cause incorrect operation, including injury, fire, and
electric shock hazards.
Do not place the power cord near a heater.
• It may cause fire and electric shock.
Do not use the power cord near flammable gas or combustibles such as gasoline, benzene, thinner, etc.
• It may cause explosion or fire.
Do not disassemble or modify products.
• It may cause failure and electric shock.
Service Manual 3
www.sylvane.com 1-800-934-9194
Safety Precautions
Plug in the power plug properly.
• Otherwise, it will cause electric shock or fire.
Do not modify power corDo not modify poDo not modify po dwer cor
Do not modify po length.
Do not operate or stop the unit by inserting or pulling out the power plug.
• It will cause electric shock or fire.
Use the air conditioner on a single outlet circuit.(see page 7.) Do not share the outlet with other appliances.
Do not damage or use an unspecified power cord.
• It will cause electric shock or fire.
Always plug into a grounded outlet.
• •• It will cause electr ic shoc k or fire.
Ventilate before operating air conditionerwhen gas goes out.
It may cause explosion, fire, and burn.
It will cause electric shock or fire.
Do not use the socket if it is loose or damaged.
It may cause fire and electric shock.
• No •• grounding may cause electric shock.
Do not operate with wet hands or in damp environment.
• It will cause electric shock.
4 Room Air Conditioner
Service Manual 5
Safety Precautions
www.sylvane.com 1-800-934-9194
If water enters the product, turn off the the power switch of the main body of appliance. Contact service center after taking the power­plug out from the socket.
• It will cause electric shock or failure of machine.
CAUTION
Never touch the metal parts of the unit when removing the filter.
Do not clean the air conditioner with water.
• Water may enter the unit and degrade the insulation. It may cause an electric shock.
Do not block the inlet or outlet.
They are sharp and may cause injury.
••
Ensure that the outer caseis not damaged by age orwear.
Leaving it damaged couldresult in the air conditioner falling out of the window, creating a safety hazard.
It may cause failure of appliance or
• performance deteriorate.
Be cautious not to touch the sharp edges
when installing.
It may cause injury.
Sharp edges
6 Room Air Conditioner
Dimensions
Dimensions
Outside Dimensions
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that could cause harm to the air conditioner.
This symbol indicates special notes.
NOTICE
Symbols Used in this Manual
www.sylvane.com 1-800-934-9194
470(18 1/2")525(20 11/16")
/8")
7
353(13
www.sylvane.com 1-800-934-9194
Product SpecificationsProduct SpecificationsProduct SpecificationsProduct Specifications
Specfications
MODLES
ITEMS
POWER SUPPLY
COOLING CAPACITY (Btu/h)
INPUT (W)
RUNNING CURRENT (A)
E.E.R (BTU/W.h)
OPERATING
REFRIGERANT (R-22) CHARGE
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN/COOLING
FAN MOTOR
OPERATION CONTROL
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
PROTECTOR
POWER CORD
DRAIN SYSTEM
OUTSIDE DIMENSION (inch) 18 1/2 x 13 7/8 x 20 11/16
(W x H x D)
INDOOR ( C) 26.7(DB)* 19.4(WB)**
OUTDOOR ( C) 35(DB)* 23.9(WB)**
HORIZONTAL LOUVER (UP & DOWN), AUTOSWING LOUVER (RIGHT&LEFT)
COMPRESSOR OVERLOAD PROTECTOR
FAN MOTOR INTERNAL THERMAL PROTECTOR
(mm) 469 x 353 x 526
CP08E10
1Ø, 115, 60Hz
7,800
720
6.8
10.8
490g(17.3 oz)
Ø7.0, 2ROW 14STACKS
Ø5.0, 2ROW 16STACKS
TURBO FAN
PROPELLER TYPE FAN WITH SLINGER RING
3/3
6 POLES
REMOTE CONTROLLER
THERMISTOR
SLIDE IN-OUT CHASSIS
3 WIRE WITH GROUNDING
ATTACHMENT PLUG (CORD-CONNECTED TYPE)
DRAIN PIPE OR SPLASHED BY FAN SLINGER
285g(10.1 oz)
CP06E10
6,000
560
5.1
10.7
* DB:Dry Bulb **
WB:Wet Bulb
Service Manual 7
Ser 7Ser 77
Operation
Location and Function of Controls
DESIGNED FOR COOLING ONLY
POWERFUL AND INCREDIBLE COOLING
TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE
BUILT-IN ADJUSTABLE THERMOSTAT
WASHABLE ONE-TOUCH FILTER
COMPACT SIZE
Service Manual 8
www.sylvane.com 1-800-934-9194
Operation
6. AUTO SWING
This button can automatically control the air flow direction(left+right).
9 Room Air Conditioner
www.sylvane.com 1-800-934-9194
4
Fan
Speed
Timer
0n/0ff
5
Saver
6
7
Ai r
Po wer
P ur ifi er
0
F
Fa n S p eed
Ti me r
Auto
Swing
Tem p
Mod e
A
S wi ng
hr
Auto
Temp
2
Swing
Power
1
5
6
CoolMoney
Fan
®
Only
Dry
Mode
3
1
2
4
3
dry operation.
(dehumidify operation)
7
To receive the signal from remote controller.
Loading...