Friedrich CP06 User Manual

06 CP08
CP
0
F
hr
Fan
Speed
Timer 0n/0ff
Auto
Swing
Fan
CoolMoney
Only
Saver
®
Temp
Dry
Power
Mode
0
F
hr
Fan Speed
Auto
Swing
Fan
CoolMoney
Saver
Only
®
Temp
Dry
Timer
Power
Mode
0n/0ff
200
7
Congratulations! Thank you for choosing Friedrich.
Your Friedrich unit is designed for maximum comfort and quietness.
Table of Contents
Introduction ..................................................................................2
Safety Precautions.......................................................................3
How to operate your Friedrich ...................................................5
Adjusting the Air Flow Direction.................................................6
Care and Maintenance.................................................................7
Hardware Location.......................................................................8
Installation Instructions
..........................................................
9
Troubleshooting Tips .................................................................17
Warranty ......................................................................................18
2
Introduction
115V~ 230V~
Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
Before Operating Your Unit
Make sure the wiring is adequate foryour unit.
If you have fuses, they should be of the time delay type. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in figure 1.
DO NOT use an extension cord.
The cord provided will carry the proper amount of electrical power to the unit; an extension cord will not.
Make sure that the receptacle is compatible with the wall plug provided.
This insures proper grounding. If you have a two-prong receptacle you will need to have the circuit replaced by a certified electrician with a grounded circuit that meets all national and local codes and ordinances. You must use the three-prong plug furnished with the air conditioner.
G N E
MODEL
CIRCUIT
TIME DELAY
RATING OR
FUSE
AMP VOLT
PLUG FACE
NEMA NO.
CP06 CP08
15
NOT E !
Aluminum house wiring may pose special problems. Consult a qualified electrician.
125
5-15P
Figure 1
For the Best Cooling Performance and Energy Efficiency
Keep the filter clean
Make sure that your air conditioner is always in top performing condition by cleaning the filter regularly. Instructions for removing and cleaning the filter can be found on page 7.
Provide good air flow
Make sure that the airflow to and from the unit is clear. Your air conditioner puts the air out at the side of the unit, and takes in air at the left. Airflow is critical for good operation. It is just as important on the outside of the building that the airflow around the unit exterior is not blocked.
Unit Placement
If your air conditioner can be placed in a window or a wall that is shaded by a tree or another building, the unit will operate even more efficiently. Using drapes or blinds on the sunny side of the dwelling will also add to your unit's efficiency.
Insulation
Good insulation will be a big help in maintaining desirable comfort levels. Doors should have weather stripping. Be sure to caulk around doors and windows.
ENGLISH
WARNING
Safety Precautions
To prevent injury and property damage, follow these instructions.
Incorrect operation due to ignoring instructions can cause harm or damage. The seriousness is classified by the following indications.
WARNING This symbol indicates the possibility of death or serious injury. CAUTION
This symbol indicates the possibility of injury or damage to properties only.
Meanings of symbols used in this manual are as shown below.
Never Do This
Always Do This
Plug in the power plug properly.
• Otherwise, it will cause electric shock or fire due to heat generation.
Do not operate or stop the unit by inserting or pulling out the power plug.
• It will cause electric shock or fire due to heat generation.
Do not damage or use an unspecified power cord.
• It will cause electric shock or fire.
If the power cord is damaged, it must be replaced by the manufacturer or a Friedrich-certified service agent.
Do not modify power cord length.
• It will cause electric shock or fire due to heat generation.
Do not operate with wet hands or in damp environment.
• It will cause electric shock.
Do not direct air flow directly at room occupants.
This could lead to health problems
.
3
4
6. AUTO SWING
This button can automatically control the air flow direction.
Fan
Speed
Timer
0n/0ff
Saver
6
7
Ai r
Po wer
P uri fie r
0
F
Fa n S pee d
Ti mer
Auto
Swing
Tem p
Mod e
A
S win g
hr
Auto
Temp
Swing
Power
5 6
CoolMoney
Fan
®
Only
Dry
Mode
1
2
4
3
5
3
dry operation.
(dehumidify operation)
2
1
7
To receive the signal from remote controller.
6
HSILGNE
Adjusting the Air Flow Direction
Vent Control
For maximum cooling efficiency, CLOSE the vent. This will allow internal air circulation. OPEN the vent to discharge stale air.
NOTE :
Adjusting the Air Flow Direction
Airflow can be adjusted by changing the direction of the air conditioner's louvers.
• Adjusting Horizontal Air Flow Direction
Adjusting the vertical louvers left and right will change horizontal airflow.
• Adjusting Vertical Air Flow Direction
Adjusting the horizontal louver up and down will change vertical airflow. The louver can be adjusted by pressing in at the top or button of the horizontal louver.
Adjusting horizontal air flow Adjusting vertical air flow
Part B
CLOSE
VENT
OPEN
Before using the ventilation feature, position the lever, as shown. First, pull down
A
part to horizontal line with part
.
B
Part A
0
F
hr
o t
Au
Fan
Swing
Speed
ol
Co
an
emp
F
T
ey
y
Only
r
ower
D
Mon
P
®
Saver
Mode
imer T
ff
/0
0n
0
F
hr
Auto
Fan
Swing
Speed
lMon
Coo
emp
Fan
T
y
ey
Onl
ry
ower
D
P
®
Saver
Mode
er im T 0n/0ff
7
Drain pipe
Drain cap
Care and Maintenance
Turn the power off and unplug the power plug before cleaning the air conditioner.
Air Filter
The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks (or as necessary) to maintain optimal performance of the air conditioner.
How to remove the air filter
Drainage
The base pan may overflow due to high humidity. To drain the excess water, remove the drain cap from the back of the unit and secure the drainpipe. However, excess water may
drip out of the back of the basepan, which is normal operation. When pressing the drainpipe into place, apply force in the
direction away from the fins to avoid injuring yourself.
1. Open the inlet grille upward by pulling out the bottom of the inlet grille.(a)
2. Remove the air filter from the front grille assembly by pulling the air filter up
3.Wash the filter using lukewarm water below104°F(40°
4. Gently shake the excess water from the filter.
C).(b)
When completely dry, replace the filter.
slightly.
b
8
Hardware Location
Product Features
CAUTION
This appliance should be installed in accordance with local and national wiring regulations. This manual acts as a guide to help to explain product features.
Cabinet
Front Grill
Vertical Air Deflector (Horizontal Louver)
Horizontal Air Deflector (Vertical Louver)
Air Discharge
o tu
A
g
n i w
S
l
o o C
p
n
me a F
T y lnO
y
r
eno
ew
y
r
o
D
M
P
®
r e va
S
e
d o M
r e m
iT
f
n 0/0f
Air Intake(Inlet Grille)
Air Filter
Remote Controller
HSILGNE
P u
A
r
i
i r f i e r
T
Po
e
F
T
m
a
i
w
m
n
p
e
e
S
r
r pe e
d
Mo de
gn
ot
i u A
w
S
Brace
Condenser
F a
n
S
0
p
F
dee
rh
oM
n e
y
S
a
F
ev
a
r
®
n
C
O
o
n
o
miT
yl
l
re
n0 /0ff
uA
ot
D
ry
wS
i
T pm
gn
e
M
o d
e
P
o
rew
Base Pan
Compressor
Power Cord
Control Board
Evaporator
9
ENGLISH
NOTE TO INSTALLER: Leave these instructions with the air conditioner after installation is complete.
NOTE TO CONSUMER: Keep this Installation and Operation Manual for future use.
Important notes:
It is recommended that proper attire be worn during installation. For personal safety, this air conditioner must be properly grounded. It is important to have the wall outlet and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground exists.
CAUTION:
Do not under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems ; consult a qualified electrician.
Before You Begin
Read these instructions completely and carefully.
Installation Instructions
Phillips-head screwdriverFlat-blade screwdriverRuler or tape measure
Scissors or knifePencilLevelHammer
Tools You Will Need
10
How to Install the Unit
HSILGNE
1. To prevent vibration and excess noise, make sure the unit is installed securely and firmly.
2. If possible Install the unit where the sunlight
does not shine directly on the unit.
Cooled air
Awning
Heat
radiation
3. The outside of the cabinet must extend outward for at least 12" and there should be no obstacles, such as a fence or wall, within 20" from the back of the cabinet, as it will prevent heat radiation of the
"06~"03
About
Over 20"
condenser. Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.
CAUTION: DO NOT cover or block any of the side louvers.
All side louvers of the cabinet must remain
exposed and unobstructed to the outside of the structure.
4. Install the unit with a rear, downward slope, so the back is slightly lower than the front (about 1/4" bubble on a level). This will force condensation to flow to the outside.
5. Install the unit with the bottom about 30"- 60" above the floor level.
Fence
1
/2"
Window Requirements
NOTE: All supporting parts should be secured to sturdy wood, masonry, or metal.
• This unit is designed for installation in standard double hung windows with actual opening widths from 22" to 36".
• The top and bottom window sash must open sufficiently to allow a clear vertical opening of 15" from the bottom of the upper sash to the window stool.
(With frame curtain)
22" to 36"
15" min
Interior wall
20
(Without frame curtain)
1
/12" min.
Stool
Offset
1
/2" to 11/4"
Sill
Exte
rior
Installation Kit Contents
Type A:13EA
(SCREW)
Type D:2EA
(NUT)
Type H:1EA
(FOAM-STRIP)
10mm
4
8
1
Type E:2EA
(FRAME CURTAIN)
Type K:2EA
(FRAME-GUIDE)
Type B:3EA
(SCREW)
16mm
5
9
Type F:2EA
(SILL SUPPORT)
Type L:1EA
(WINDOWLOCKINGBRACKET)
2
Type C:5EA
(SCREW)
3
16mm
6
10
Type G:2EA
(BOLT)
Type M:1EA (FOAM-PE)
7
10mm
11
Type N:1EA
(DRAIN JOINT PIPE)
12
Have the following tools available for installation: * Screwdriver (Slotted and Phillips) * Ruler
* Knife * Hammer * Pencil * Level
11
HSILGNE
PREPARATION OF CHASSIS
1. Remove the screws which fasten the cabinet at both sides and at the back.
2. Slide the unit out from the cabinet by gripping
the base pan handle and pulling forward while bracing the cabinet.
3. Cut the window sash seal to the proper length.
Peel off the backing and attach the Foam-PE to the underside of the window sash.
4.
5.
6.
Insert the Frame guides into the bottom of the cabinet.
Insert the Frame Curtain into the and Frame Guides.
Fasten the curtains to the unit with 8 Type A screws.
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Suggested Tool Requirements
SCREWDRIVER(+, -), RULER, KNIFE, HAMMER, PENCIL, LEVEL
(Fig .1)
(Fig .2)
(Fig .4)
(Fig .4)
(Fig .3)
Upper Guide
Shipping screws
F
an
0
S
F
p e
e d
hr
Mo
ney
Sa
ve
F a
r
n
®
C
On
o
o l
l
T
y
imer
A u
0n
t o
/0
S
ff
Dr
win
y
g
T e mp
Mo
d e
Power
F a
0
n
S
F
p
e e
d
hr
oney Save
Fan
r
®
C
On
oo
lM
T
l y
i mer
A
u
0n/0
t
o
S
f
D
w
f
r
ing
y
T
emp
Mod
e
Power
(Fig .4)
Foam-PE
Upper guide
Screw
(Type A)
1
12
Frame guide
Screw(Type A)
1
9
13
Cabinet Installation
1. Open the window. Mark a line on center of the window stool. window stool and align the center mark on the
bottom front with the center line marked in the window stool. (Fig. 1)
2. Pull the bottom window sash down behind the
Upper Guide until they meet.
Carefully place the cabinet on the
Upper Guide
(Fig. 2)
Window stool
Front Angle
Fig. 1
Window Sash Upper guide
NOTE: Do not pull the window sash down so
tightly that the movement of Frame Curtain is restricted.
3. Loosely assemble the Sill Support using
5
6
the parts . (Fig. 3)
4. Select the position that will place the Sill
Support near the outer most point on sill.
6
(Fig. 4)
NOTE: Be careful when you install the cabinet
(Frame Guides are broken easily).
5. Attach the Sill Support to the cabinet track
9
6
hole in relation to the selected position using 2 -type A screws in each support. ( Fig. 4).
Foam-PE
11
Cabinet
Frame Curtain
7
Frame Guide
5
Foam-PE
9
Sill Support
4
NutBolt
Screw(Type A)
Cabinet
Fig. 2
ROODTUOROODNI
6
Fig. 3
1
/2"
1
About
ROODTUOROODNI
Fig. 4
14
Fig. 8
6. The cabinet should be installed with a very slight tilt (about 1/2") downward toward the outside (See Fig. 5). Sill Support for balancing the cabinet.
Adjust the bolt and the nut of
6
7. Attach the cabinet to the window stool by driving the screws [Type B: Length 16mm (5/8 inch)
2
and below.] through the front angle into window stool.
(Fig. 5)
Screw(Type B)
2
"
2
/
1
About
Sill Support
Sash track
6
8. Pull each Frame Curtain to each window sash track, and repeat step 2.
9. Attach each Frame Curtain to the window sash using screws (Type C). ( Fig. 6)
5
(Fig. 5)
5
3
CAUTION: Do not drill a hole in the bottom pan.
The unit is designed to operate with approximately 1/2" of water in bottom of pan. There is no need to add water if the pan is dry.
10. Slide the unit into the cabinet. ( Fig. 7)
CAUTION: For security purposes, reinstall the 2
screws (Type A) at cabinet's side, that were removed in step 1 on page 12.
Sill Support
6
Screw(Type A)
Screw(Type B)
F a
0
n
Sp
F
e e
d
hr
M on
e y
Save
F a
r
n
®
C
O
o o
n
l
ly
T i
m e
Auto
r 0 n/0
Sw
ff
D r
i
y
ng
T e m p
M od
e
P o
w e
1
r
Front Angle
2
Type C
Power cord
Fig. 5
3
Fig. 6
11. Cut the Foam-Strip to the proper length
8
(window width) and wedge between the upper window sash and the lower window sash. ( Fig. 8)
Screw(Type A)
1
Fig.7
Foam-Strip
8
15
12. Attach the Window Locking Bracket with a Type C screw . ( Fig. 9)
3
10
13. Attach the front grille to the cabinet by inserting the tabs on the grille into the tabs on the front of the cabinet. Push the grille in until it snaps into place. (Fig. 10)
14. Pull down the inlet grille and secure it with a Type A screw through the front grille. ( Fig. 11)
1
15. Window installation of room air conditioner is now
completed. See ELECTRICAL DATA for plugging the power cord into the properly
rated electrical outlet.
Window locking bracket
10
Fig. 9
Fig. 10
o Aut Swing
l o Co
p
em
an
T
F ly
er
ey
y
n
On
r
ow
D
P
Mo
®
aver S
Mode
Timer
f f
0n/0
Fig. 11
IMPORTANT
IMPORTANT
NOTE:
(cont.)
FINISH THE WALL OPENING
The case may be
in both existing and new construction.
Read completely, then follow step-by-step.
Secure with 14 wood screws anchored at Ieast an inch into the wall support structure.
Drill pilot holes, if necessary, for proper installation. If the frame is oversized, use shims to prevent case distortion.
Caulk all four sides on the outdoor side of
the case to prevent moisture from getting
through to the interior wall. Use of flashing (drip rail) will further prevent water from dripping inside the wall and down the
outsida of the building.
NOTE: Obtain all materials locally for mounting the air conditioner through
the wall.
Through-the-wall installation is not
appropriateif any of the side or top louvers in the case will be obstructed by the wall.
All side and top louvers in the case must
project on the outdoor side of the wall. The room side of the case must project
into the room far enough to maximize the balance of the unit.
The case must be installed level from side­to side and with a slight tilt from front to rear. Use a level; no more than a 1/2 bubble will be the correct case slant to the outside.
installed through
the wall
-
-
- -
1
1
D
A
2
Lintel angle is required to support bricks or blocks above opening.
Flashing is required and should extend the length of the opening to ensure no inside cavity leakage occurs.
Remove the air conditioner from the case.
For specific instruction, refer to the Window
Installation Instructions.
Make certain that a wall receptacle is available close to the hole location or make arrangementsto install a receptacle.
Place the case in the wall opening and
Place the air conditioner into the case. For specific instruction, refer to the Window Installation Instructions.
place wood support strips betweenthecase
bottom and the flashing on both sides of the bottom rail. They should be the same height
as the bottom rail and the same length as
the wall opening.
A
B
C
B
Through-the-Wall Installation Instructions-Optional
16
17
Troubleshooting Tips
Troubleshooting Tips save time and money! Review the chart below first and you may not need to call for service.
oD oT tahWsesuaC elbissoPmelborP
The air conditioner is unplugged.
The fuse is blown/circuit breaker is tripped.
Power failure.
The current interrupter
device was tripped on the power cord.
Airflow is restricted.
The THERMOSTAT may
not be set high enough.
The air filter is dirty.
The room may have been
hot.
Cold air is escaping.
Cooling coils have iced up.
Ice blocks the air flow and
stops the air conditioner from cooling the room.
• Make sure the air conditioner plug is pushed completely into the outlet.
• Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.
• If power failure occurs, turn the mode control to Off. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.
• Press the RESET button located on the power cord plug. If the RESET button will not stay eng aged, discontinue use of the air conditioner and contact a qualified service technician.
• Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner.
• Push temperature setting button to coolest temperature setting of 60°F.
• Clean the filter at least every 2 weeks. See the operating instructions section.
• When the air conditioner is first turned on you need to allow time for the room to cool down.
• Check for open furnace floor registers and cold air returns.
• Set the air conditioner's vent to the closed position.
• See Air Conditioner Freezing Up below.
• Set the mode control on high fan until the ice thaws out. This may indicate a bigger problem.
Air conditioner does not start
Air conditioner does not cool as it should
Air conditioner freezing up
Normal Operation
• You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
• You may hear the thermostat click when the compressor cycles on and off.
• Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
• The fan may run even when the compressor does not.
• Your air conditioner is designed to cool in warm weather when the outside temperature is above 60°F(16°C) and below 115°F(46°C).
Abnormal Operation
Loading...
+ 41 hidden pages