Compact Programmable
Room Air Conditioners
PURCHASER P.O. # DATE
PROJECT LOCATION
ENGINEER ARCHITECT
SUBMITTED BY FOR APPROVAL FOR REFERENCE
ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH MODEL
COMPACT SIZE FOR EASIER REMOVAL and STORAGE | 5,000 BTU/h EER 9.7
• 12-hour electronic timer lets
you program on/off times
• Three cooling speeds, plus three
fan-only settings
• Energy effi cient for low operating cost
• Stale air exhaust vent
• Four-way air fl ow control
COMPACT and SMALL SIZE FOR EASIER REMOVAL and STORAGE | 6,000 to 11,800 BTU/h EERs up to 10.8
• Auto Air Sweep swing louvers
provide even air distribution
• 12-hour electronic timer lets
you program on/off times
• MoneySaver® setting saves
energy by cycling the fan with
the compressor
• Three cooling speeds, plus
three fan-only settings
• Energy effi cient for low operating cost
MEDIUM SIZE FOR EASIER REMOVAL and STORAGE | 14,000 to 23,500 BTU/h EERs up to 9.8
• Fixed chassis
• One-touch, lift out fi lter
• Auto-restart
• Dry Mode for greater dehumidifi cation
• Expandable side curtains included to
block light and noise and to allow for
easier removal and storage
• Stale air exhaust vent
• Four-way air fl ow control
• Slide-out chassis for more permanent
window or wall installation
• One-touch, lift out fi lter
• Auto-restart
• Dry Mode for greater dehumidifi cation
• Expandable side curtains included to
block light and noise and to allow for
easier removal and storage
• Auto Air Sweep swing louvers
provide even air distribution
• 24-hour electronic timer lets
you program on/off times
• MoneySaver® setting saves
energy by cycling the fan with
the compressor
• Three cooling speeds, plus
three fan-only settings
CP_SUBMITTAL_08 (3-08)
• Energy effi cient for low operating cost
• Stale air exhaust vent
• Slide-out chassis for easy
window or wall installation
• Expandable side curtains
included
• Easy access, lift out fi lter

Speci cations
ENERGY STAR
★
®
Models
Energy
Efficiency
Ratio
EER
Moisture
Removal
Pints/Hr.
Room Side
Air Circulation
CFM Sleeve
Cooling
Capacity
BTU/h
Heating
Capacity
Rated
Electrical Characteristics (60 Hertz)
Volts
Rated
Cooling
Amps
Cooling
Watts
Heating
Amps
Heating
Watts
COMPACT PROGRAMMABLE
CP0 5N10 500 0 — 115 4.8 515 — — 9.7 1. 3 135 P1 49
CP06E10 6000 — 115 5.1 560 — — 10.7 1.8 210 P6 60
★
CP08E10 7800 — 115 6.8 720 — — 10.8 3.0 250 P6 66
★
CP10E10 10000 — 115 8.5 920 — — 10.8 3.0 270 P7 95
★
CP12E10 12000 — 115 10.2 1110 — — 10.8 3.0 280 P7 100
★
CP14 N10 1400 0 — 115 12 .0 14 30 — — 9.8 4.3 370 P4
CP18N30 1800 0/17600 — 230/208 8 .2/8.8 1850/ 1810 — — 9.7/9.7 5.0 375 P4
CP24N30 23500/23100 — 230/208 12.0/13.1 2740/2710 — — 8.6/8.5 6.3 400 P5
Due to continuing research in new energy-saving technology, specifications are subject to change without notice.
Installation Information / Sleeve Dimensions
Sleeve Height Width
P1† 12 ¼" 18 ½" 15" 5" 3 ½" 10 ¾" 22" 36"
P4 17 ½" 26" 27 5⁄8"8
P5 17 ½" 26" 29 ¾" 8 7⁄8" 5 ½" 19 ½" 27" 42" 17 ¾" 26 ¼"
P6 13 5⁄8" 18 ½" 20 5⁄8"8
P7 15" 23 5⁄8" 22 ¼"" 8 ¾" 4 ½" 12 27" 39" 15 ¼" 23 7⁄8"
with Front
Depth
Hood to
Louvers
7
1
Depth
Minimum
Extension
Into Room
⁄8"5 ½" 16 5⁄8" 27" 42" 17 ¾" 26 ¼"
⁄8" 4 ½" 11" 22" 36" 13 7⁄8"18 ¾"
Minimum
Extension
Outside
Window Width
Minimum Maximum Height Width
Thru-the-wall
Finished Hole
NOT FOR THRU-WALL
Net
Weight
Lbs
119
150
163
. Model
† Sleeve P1 does not have thru-the-wall hole dimensions, as these units are fixed chassis and should not be installed thru-the-wall.
Circuit Rating/ Breaker
Circuit Rating
Model
CP05, CP06, CP08, CP10, CP12 and CP14.
CP18
CP24
★ As an ENERGY STAR
®
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR
Breaker or
T-D Fuse
125V - 15A 5 - 15P
250V - 15A 6 - 15P
250V - 20A 6 - 20P
The consumer- through the AHAM Room Air Conditioner Certification Program- can be certain that the AHAM Certification Seal accurately
states the unit’s cooling and heating capacity rating, the amperes and the energy ef ficiency ratio.
Plug Face
(NEMA#)
Wall Outlet
Appearance
®
(★) models meet the ENERGY STAR
®
guidelines for energy efficiency.
CP_SUBMITTAL_08 (3-08)