Friedrich CP05 User Manual

Page 1
ROOM AIR CONDITIONERS
cool only | heat pumps | electric heat
Page 2
Built for the most demanding applications.
built tough
HEAVY GAUGE STEEL
20 gauge steel is used in order to create a more robust air conditioner cabinet that will with­stand years of hard use.
ALUMINUM REAR GRILLE
SOLID SLEEVE TOP*
Keeps out falling debris, which can obstruct the fan and prevent it from turning, thus damaging the unit.
FAN MOTOR
Larger, commercial grade fan mo­tor runs at lower temperature than smaller fan motors, which:
• prevents unit from overheating
• contributes to longer life
Totally enclosed for maximum protection and longer life.
quiet by design
QUIET AS A GENTLE RAIN
QuietMaster model has a Decibel rating of 48, which is less than the sound of rainfall (50 db).
SS10 sound power rating o n low fan speed.
EXTR A THICK RUBBER GROMMETS
Absorbs motion and sound to reduce unwanted noise.
VIBRATION ISOLATOR
Vibration and noise isolating tec hnolo gy.
PROTECTIVE MOTOR MOUNT
Two resiliant rings on motor mount prevent metal-to-metal contact, which eliminates extra vibration and noise.
ADVANCED AIRFLOW TECHNOLOGY
Cutting edge engineering is behind this unique design which lets more air through as space increases.
QUALITY
ALUMINUM ENDPLATES
Won’t rust like leading competitors’ steel, which rusts when exposed to condensate that can collect in drain pan. Rust can run down the sides of buildings creating an unsightly exterior that is expensive to repair. Signicantly extends life of unit.
Residential grade products may dier.
Absolutely! While our commercial grade line is tough
Commercial
grade for my
home?
enough for industrial use, our engineers designed Friedrich air conditioners with your family’s comfort and convenience in mind.
Yes, we use top quality components. Yes, they are ultra energy ecient. Yes, they are built to stand the test of time. But, we think your family is worth it.
BLOWER WHEEL HOUSING
Solid steel for maximum sound reduction.
SCIENTIFIC REFRIGERATION DESIGN
Better design for quieter performance.
HEAVY DUTY SIDE CURTAINS
Or solid masonite side wings block outside noise and light.
INSULATED PLENUM
Insulated plenum helps keep outside noise outside.
Page 3
leading energy eciency
A 125 YEAR HISTORY of BUILDING QUALITY PRODUCTS
SAVE UP TO $747
You can save hundreds of dollars in operating costs compared to less ecient units. The ten year savings of model EM24L34, 9.5 EER is $747
HIGH EFFICIENC Y COMPRE SSORS
Quiet, smooth power and energy ecient compressors are at the heart of every Friedrich unit.
MONEYSAVER MODE
Turns o the fan when the compressor stops, saving money by operating only when required.
HIGHTECH FINS
Sine wave, lanced louvers increase energy eciency by increasing surface area for heat exchange.
RIFLED COPPER TUBING
Greater surface area for heat exchange, increasing the eciency of the coils, which improves overall eciency of the unit.
**
***
Styled for
the most
discriminating
customers
UNIQUE COMFORTWATCH TECHNOLOGY
Friedrich models maintain an even room temperature through advanced technology that more accurately anticipates room temperature uctuations. Other brands may be fooled into shutting o prematurely when the unit’s internal temperature sensor is cold, even if the room has not reached the desired temperature.
Residential grade products may dier.
*Model XQ12 has top louvers.
**
Compared to a mo del with 8.5 EER, ope rated 2200 hours per yea r for ten years at 10.8 ¢/kw hour.
***
Not available on model EQ08.
Page 4
precise temperature control
remote control convenience.
First Friedrich air conditioner 1952
Do you need a rugged, dependable unit that can take heavy commercial use?
Or do you just want the very best air conditioner for your home and family?
Built to last. Trusted for generations.
FOR GENERATIONS, families have trusted Friedrich to build products of lasting quality. Quality that has won awards time and again.
Today we build that trust into the next generation of products. Smart, programmable models that are easy to use, provide fast, powerful cooling and achieve exceptional energy eciency.
Either way, there’s a Friedrich that’s just right for you.
Friedrich is a partner in the Energy Star® program which promotes the conservation of energy and the protec tion of the environment through the purchase of high eciency appliances.
comfort tips
Want to reduce your energy costs and stay nice and cool?
Select the ‘MONEY SAVER’ setting to run the fan only when the compressor is running.
Select the ‘SMART FAN’ setting and your Friedrich will automatically adjust the fan speed to deliver a constant, comfortable temperature in any environment.
Page 5
FRIEDRICH TOP
of THE LINE ROOM AIR CONDITIONERS
COMMERCIAL GRADE Programmable models
ONE TOUC H
OP ER ATIO N
COMPACT SIZE FOR E ASIER R EMOVAL AND STOR AGE
DIGI TAL CONTRO L FEATU RES
• 24-hour timer lets you program on/o times
• 3 cooling speeds, plus fan-only setting
• MoneySaver® setting saves energy by cycling the fan with
the compressor
• Smart Fan adjusts fan speed to maintain desired temperature
• Unique Comfortwatch technology
• Memory backup saves settings if power is interrupted
DELU XE FE ATURES
• Ultraquiet operation
• 8-way air ow control
• Slide-out chassis for more permanent window or
wall installation
• Washable, antimicrobial lter for protection against fungal
and bacterial growth
• Heavy duty side curtains reduce exterior noise/ light
• Rust proof base pan
REMOTE
CONTROL
24 HR. TIMER
MONEY SAVER
FEATURE
SMART
FAN
ANTIMICROBIAL
FILTER
FITS WINDOWS– MINIMUM: 26” WIDE. MAXIMUM: 42” WIDE
FITS WINDOWS– MINIMUM: 26” WIDE. MAXIMUM: 42” WIDE
THE INDUSTRY’S SMALLEST SLIDE-OUT
CHASSIS- MODEL XQ05
SLIDE-OUT
CHASSIS
Three E n E rg y S t a r ® models
ONE TOUC H
OP ER ATIO N
SMA RT CEN TER CO NTROL S
FULL SIZE FOR MORE PERM ANE NT IN STALL ATION
DIGI TAL CONTRO L FEATU RES
• 24-hour timer lets you program on/o times
• 4-speed fan with ultraquiet “Sleep Setting”
• Smart Fan adjusts fan speed to maintain desired temperature
• Unique Comfortwatch technology
• MoneySaver® setting saves energy by cycling the fan with
the compressor
• Memory backup saves settings if power is interrupted
• Check lter reminder light
DELU XE FE ATURES
• Ultraquiet operation
• 8-way air ow control
• Fresh air intake/ stale air exhaust vents
• Washable, antimicrobial lter for protection against fungal
and bacterial growth
• Slide-out chassis for more permanent window or
wall installation
5,500 to 11,700 BTU/h EERs up to 11.5
5,500 to 11,700 BTU/h EERs up to 11.5
REMOTE
CONTROL
24 HR. TIMER
MONEY SAVER
FEATURE
SMART
FAN
ANTIMICROBIAL
FILTER
SLIDE-OUT
CHASSIS
FITS WINDOWS– MINIMUM: 27 7/8” WIDE. MAXIMUM: 42” WIDE
FITS WINDOWS– MINIMUM: 27 7/8” WIDE. MAXIMUM: 42” WIDE
Eight E n E r g y St a r ® models
8,400 to 23,500 BTU/h EERs up to 12.0
8,400 to 23,500 BTU/h EERs up to 12.0
Page 6
Do you have a room or area that’s always too hot or too cold?
Installing a TwinTemp heat pump or electric heat model is a perfect, low-cost solution.
enjoy year‘round comfort
Want to clear the room of stale air or cooking
comfort tips
smoke?
Slide the vent lever to ‘EXHAUST’ and set the fan to ‘FAN ONLY’–out goes the bad air.
Sometimes the air outside is cooler than the air inside. If you don’t want to open a window, slide the vent lever to ‘FRESH AIR’ and set the fan to ‘FAN ONLY’ to bring cool outdoor air in.
Page 7
FRIEDRICH TOP
of THE LINE ROOM AIR CONDITIONERS
COMMERCIAL GRADE Manual control models
FULL SIZE FOR MORE PERM ANE NT IN STALL ATION
DELU XE FE ATURES
• Ultraquiet operation
• MoneySaver® setting saves energy by cycling the fan with
the compressor
• 4 cooling speeds, plus fan-only setting
• Heat anticipating thermostat
• 8-way air ow control
• Fresh air intake and stale air exhaust
• Rotary controls
• Slide-out chassis for more permanent window or wall
installation
• Washable, antimicrobial lter for protection against fungal
and bacterial growth
• Largest capacity AHAM certied unit available
Four E n E r g y St a r ® models
MONEY SAVER
FEATURE
FITS WINDOWS– MINIMUM: 27 7/8”* WIDE. MAXIMUM: 42” WIDE
*SL models fit win dows a minimum of 29 7/8” wid e.
ANTIMICROBIAL
FILTER
SLIDE-OUT
CHASSIS
11,600 to 36,000 BTU/h EERs up to 11.0
COMPACT SIZE FOR E ASIER R EMOVAL AND STOR AGE
AND FULL SIZE FOR MORE PER MANENT INSTALLATION
DELU XE FE ATURES
• Heat pumps are ideal for southern climates; heat pump and electric heat models provide
supplemental heating in colder climates*
• Ultraquiet operation
• MoneySaver® setting** saves energy by cycling
the fan with the compressor
• 3 cooling/3 heating speeds***, plus fan-only setting
• Heat anticipating thermostat
• 8-way air ow control
• Defrost control (heat pumps)
• Fresh air intake and stale air exhaust vents*
• Rotary controls
• Washable, antimicrobial lter for protection
against fungal and bacterial growth
• Slide-out chassis for more permanent window or wall installation (window installation requires optional window kit)
MONEY SAVER
FEATURE
T WI NT EM P U NI TS I N S TALL T HR U- WALL OR IN A W IN D OW WI TH
MODEL EQ08L11A
OPTIONAL WINDOW KIT. SEE SPECIFICATIONS.
ANTIMICROBIAL
FILTER
HEAT/COOL
SLIDE-OUT
CHASSIS
Three E n E rg y S t a r ® models
COOLING 7,700 to 36,000 BTU/h HEATING 4,000 to 22,000 BTU/h EERs up to 12.0
* Feature not available on model YS09L10. **Feature not available on model EQ08L11A. ***EQ08L11A has 2 cooling and 2 heating speeds, plus fan-only.
Page 8
FRIEDRICH CP ROOM AIR CONDITIONERS
RESIDENTIAL GRADE programmable control models
COMPACT PROGRAMMABLE
COMPACT SIZE FOR E ASIER R EMOVAL AND STOR AGE
DELU XE FE ATURES
• 12-hour programmable timer lets you set on/o times
• 3 cooling speeds, plus 3 fan-only settings
• Energy ecient for low operating cost
• Stale air exhaust vent
• 4-way air ow control
• Fixed chassis
• One-touch, lift out lter
• Auto-restart
• Dry Mode for greater dehumidication
• Expandable side curtains included to block light and noise
and to allow for easier removal and storage
COMPACT AND SMALL SIZE FOR EASIER REMOVAL AN D STOR AGE
DELU XE FE ATURES
• Auto Air Sweep swing louvers provide even air distribution
• 12-hour programmable timer lets you set on/o times
• MoneySaver® setting saves energy by cycling the fan with
the compressor
• 3 cooling speeds, plus 3 fan-only settings
• Super high energy eciency for low operating cost
• Stale air exhaust vent
• 4-way air ow control
• Slide-out chassis for more permanent window or wall
installation
• One-touch, lift out lter
• Auto-restart
• Dry Mode for greater dehumidication
• Expandable side curtains included to block light and noise
and to allow for easier removal and storage
REMOTE
CONTROL
FITS WINDOWS– MINIMUM: 22” WIDE. MAXIMUM: 36” WIDE
12 HR. TIMER
5,000 BTU/h EER 9.7
REMOTE
CONTROL
FITS WINDOWS– MINIMUM: 22” WIDE. MAXIMUM: 36” WIDE
MODELS CP06, CP08
FITS WINDOWS– MINIMUM: 27” WIDE. MAXIMUM: 39” WIDE
12 HR. TIMER
MONEY SAVER
FEATURE
SLIDE-OUT
CHASSIS
Four E n E r g y St a r ® models
MODELS CP10, CP12
6,000 to 11,800 BTU/h EERs up to 10.8
Page 9
FRIEDRICH CP ROOM AIR CONDITIONERS
RESIDENTIAL GRADE programmable control models
COMPACT PROGRAMMABLE
MEDIUM SIZE FOR EASIE R RE MOVAL AND STORAGE
DELU XE FE ATURES
• Auto Air Sweep swing louvers provide even air distribution
• 24-hour electronic timer lets you program on/o times
• MoneySaver® setting saves energy by cycling the fan with
the compressor
• 3 cooling speeds, plus 3 fan-only settings
• Energy ecient for low operating cost
• Stale air exhaust vent
• Slide-out chassis for easy window or wall installation
• Expandable side curtains included
• Easy access, lift out lter
REMOTE
CONTROL
FITS WINDOWS– MINIMUM: 27” WIDE. MAXIMUM: 42” WIDE
24 HR.
TIMER
MONEY SAVER
FEATURE
SLIDE-OUT
CHASSIS
“Have a Friedrich
Air Conditioner in
my bedroom that is
approximately 40 years
old. It looks good and
cools good and I use it
daily”.
14,000 to 23,500 BTU/h EERs up to 9.8
E. Williams
website comment
March 2006
quality that lasts – that’s Friedrich
Page 10
Specications
Cooling
Capacity
BTU/h
Heating
Capacity
Rated
Electrical Characteristics (60 Hertz)
Energy
Efficiency
Ratio
EER
Moisture Removal Pin ts/ Hr.
Room Side
Air Circulation
CFM Sleeve*
Net
Weight
Lbs. Model
Volts
Rated
Cooling
Amps
Cooling
Watts
Heating
Amps
Heating
Watts
COMM ERCIAL GRAD E
XSTAR
XQ05L10A 5500 115 5.0 500 11.0 1.2 200 Q 70
XQ06L10A 6300 115 4.9 548 11.5 1.4 175 Q 70
XQ0 8L10A 8000 115 6.8 741 10.8 1.9 175 Q 77 XQ10L 10A 10000 115 9.0 1000 10.0 3.2 180 Q 83 XQ12L 10A 1170 0 115 11.0 119 8 9.8 3.2 200 Q 83
QUIETMASTER Programmable
SS0 8L10 8400 115 6.6 737 11.4 1.6 265 S 10 8
SS10L 10 10400 11 5 7. 5 867 12.0 2.5 260 S 115
SS12L 10 1180 0 115 9.0 1000 11 .8 2.5 350 S 114
SS14 L10 14000 115 12.0 1305 10.7 3.5 377 S 128
SS12L 30 12100/ 11900 230/208 4.8/5.0 1052 /1017 11.5/11.7 2.9 320 S 114 SS16 L30 16200/15900 230/208 7.4 / 8. 0 1653/1656 9.8/9.6 4.7 360 S 119
SM18L30A 1750 0/1730 0 230/208 7. 2/ 7. 7 1620 /1570 10.8/10.8 4.5 375 M 16 3
SM21L 30 20600/20200 230/208 9.4/ 10.1 2081/2020 9.9/10.0 6.0 425 M 15 4
SM24L30 23500/23000 230/208 11.2 /12. 1 2479/ 2421 9.5/9.5 7. 0 400 M
154
QU IET MAS TER
KS12L 10 1160 0 11 5 9.0 1055 11. 0 2.5 356 S 114
KS15L 10 14 500 11 5 12.0 1343 10.8 3.5 377 S 128 KM18 L30 17800 /17600 230/208 8.1/8.8 178 0/1760 10.0/10.0 4.4 400 M 161
KM24 L30 23500/23000 230/208 11. 2/12 .1 247 9/2421 9.5/9.5 7. 0 490 M 154
SL28L30 28000/27700 230/208 13. 0/14. 2 2947/2916 9.5/9.5 8.8 600 L 201 SL36L30A 36000/35700 230/208 18.0/19.6 4235/4200 8.5/8.5 11 .0 725 L 220
TWINTEMP Heat Pump
YS0 9L10** 9200 74 00 115 7. 4 767 6.9 733 12.0 1.7 300 S 113
YS13L 33 12700/12500 11000/10500 230/208 5.1/5.6 114 9/1131 5.3/5.8 1185 /1167 11.0/11.0 3.5 325 S 117 YM18 L34 18000/18000 168 00/16 400 230/208 8.5/9.5 1895/1895 8.5/9.0 18 67/1822 9.5/9.5 4.7 400 M 16 6
YL 24L35 24000/24000 22000/21600 230/208 10.9/12.0 2400/2400 11.0/12.0 2444 /2400 10.0/10.0 7.0 600 L 198
TWINTEMP Electric Heat
EQ 08L11 A 7700 4000 115 6.5 733 11.2 1290 10.5 1.9 175 Q 76 ES12L 33 12100/11900 10700/8900 230/208 4.8/5.0 1052/ 1017 16. 0/14. 7 3500/2900 11.5/11 .7 2.9 320 S 111 ES16 L33 16200/15900 10700/8900 230/208 7. 4/ 8 .0 1653/1656 16. 0/14. 7 3500/2900 9.8/9.6 4.7 360 S 116 EM18 L34 1780 0/1760 0 13000/10600 230/208 8.1/8.8 1780 /1760 19 .5 / 17. 0 4200/3500 10.0/10.0 4.4 400 M 160 EM24 L34 23500/23000 13000/10600 230/208 11.2 /12.1 2479 /2421 19. 5 /1 7.0 4200/3500 9.5/9.5 7. 0 400 M 154 EL36L35A 36000/35700 17300/14300 230/208 18.0/19.6 4235/4200 24.0/22.4 5500/4650 8.5/8.5 11.0 725 L 220
RESIDENTIAL GRADE
COMPACT PROGRAMMABLE
CP0 5N10 5000 115 4.8 51 5 9.7 1.3 135 P1 49
CP0 6E10 6000 115 5.1 560 10.7 1.8 210 P6 60
CP0 8E10 7800 115 6.8 720 10.8 3.0 250 P6 66
CP10E 10 10000 115 8.5 920 10.8 3.0 270 P7 95
CP12E 10 12000 115 10.2 1110 10.8 3.0 280 P7 10 0 CP14N10 14000 115 12.0 14 30 9.8 4.3 370 P4
119
CP18N30 18000/17600 230/208 8.2/8.8 185 0/1810 9.7/9.7 5.0 375 P4
150
CP24N30 23500/23100 230/208 12.0/13.1 2740/2710 8.6/8.5 6.3 400 P5
163
ENERGY STAR
®
Models
* Sleeve dimensions listed on opposite page. ** Operates on 115 volt and is not equipped with supplemental heat. Will not provide heat at temperatures below 40°F. Friedrich room air conditioners are designed to operate in outdoor temperatures from 50°
TwinTemp Heat Pump heating information heat strip performance. For TwinTemp Heat Pump electric heating performance refer to corresponding TwinTemp Electric Heat model.
Due to continuing research in new energy-saving technology, specifications are subject to change without notice.
(shown in red) indicates heat pump heating performance. TwinTemp Electric Heat heating information (shown in red) indicates electric
F to 115° F.
As an ENERGY STAR
®
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR
The consumer- through the AHAM Room Air Conditioner Certification Program- can be certain that the AHAM Certification Seal accurately states the unit’s cooling and heating capacity rating, the amperes and the energy efficiency ratio.
®
() models meet the ENERGY STAR
®
guidelines for energy efficiency.
Page 11
Model
Circuit Rating
Breaker or
T-D Fuse
Plug Face (NEMA#)
Wall Outlet
Appearance
CP05, CP06, CP08, CP10, CP12 and CP14. All XQ MODELS. KS12L10 and KS15L10. SS08L10, SS10L10, SS12L10 and SS14L10. EQ08L11A. YS09L10.
125V - 15A 5 - 15P
CP18. KM18L30. SS12L30, SS16L30, SM18L30A and SM21L30.
250V - 15A 6 - 15P
CP24. KM24L30. SM24L30 and SL28L30. ES12L33 and ES16L33. YS13L33.
250V - 20A 6 - 20P
SL36L30A. EM18L34, EM24L34 and EL36L35A. YM18L34 and YL24L35.
250V - 30A 6 - 30P
Installation Information / Sleeve Dimensions
Sleeve Height Width
Depth
with Front
Depth Hood to Louvers
Minimum
Extension
Into Room
Minimum
Extension
Outside
Window Width
Thru-the-wall Finished Hole
Minimum Maximum Height Width
Q 14 " 19 ¾" 21 3∕8" 8 ½" 5 ½" 10 ¾"
26" 42" 14 ¼" 20"
P1† 12 ¼" 18 ½" 15" 5" 3 ½" 10 ¾" 22" 36"
NOT FOR THRU-WALL
P4 17 ½" 26" 27 5∕8" 8 7∕8" 5 ½" 16 5∕8" 27" 42" 17 ¾" 26 ¼"
P5 17 ½" 26" 29 ¾" 8 7∕8" 5 ½" 19 ½" 27" 42" 17 ¾" 26 ¼"
P6 13 5∕8" 18 ½" 20 5∕8" 8 1∕8" 4 ½" 11" 22" 36" 13 7∕8" 18 ¾"
P7 15" 23 5∕8" 22 1∕8"" 8 ¾" 4 ½" 12 27" 39" 15 ¼" 23 7∕8"
S 15 15∕16" 25 15∕16" 27 3∕8" 8 ¾" 3 1∕16" 16 15∕16" 27 7∕8" 42" 16 3∕16" 26 3∕16"
M 17 15∕16" 25 15∕16" 27 3∕8" 8 ¾" 3 1∕16" 16 15∕16" 27 7∕8" 42" 18 3∕16" 26 3∕16"
L 20
3
∕16" 28" 33 5∕8" 16 ½" 3 3∕16" 18 15∕16" 29 7∕8" 42" 20 3∕8" 28 ¼"
TwinTemp Model Kit No.
EQ08L11A WIKQ
ES12L33, ES16L33, YS09L10 and YS13L33. WIKS
EM18L34, YM18L34 and EM24L34. WIKM
EL36L35A and YL24L35. WIKL
Sleeve P1 does not have thru-the-wall hole dimensions, as these units are fixed chassis and should not be installed thru-the-wall.
Circuit Rating/ Breaker
Window Mounting Kits
TWINTEMP® models include accessories for thru-the-wall installation only. Window mounting requires use of optional accessory kit as listed above.
Room Air Conditioner Model Identication Guide
S L 28 L 3 0 A
FUNCTION S–Straight Cool C–Straight Cool X–Straight Cool K–Straight Cool
Y–Heat Pump E–Electric Heat
CHASSIS Q–Portable P–Programmable S–Small Chassis M–Medium Chassis L–Large Chassis
MODEL SERIES
APPROXIMATE BTUS (000) Cooling
Letter at end of model number indicates a modification to an existing model.
0 – Straight Cool and 115V Heat Pump Models
1 – 1 KW heat strip, Nominal 3 – 3 KW heat strip, Nominal 4 – 4 KW heat strip, Nominal 5 – 5 KW heat strip, Nominal
VOLTAGE 1–115 Volts 3–230/208 Volts
Page 12
Multiple solutions. One trusted name.
A full line of air conditioning solutions.
PORTABLE AIR CONDITIONERS
Easy cooling. Anytime. Any place. Great for fast back-up or supplemental cooling. Plug into a standard 115 volt outlet. They can be quickly vented through a window or wall opening. Full display electronic controls and remote control.
IDEAL FOR: Temporary or permanent cooling in workshops,
garages, home oces, dorm rooms, sunrooms, bedrooms, attics and basements.
THRUTHEWALL AIR CONDITIONERS
Residential and commercial applications. A high eciency replacement for older units. IDEAL FOR: Deep exterior walls; can be installed ush with exterior wall and oor level.
PACKAGED TERMINAL AIR CONDITIONERS
Energy ecient and extremely quiet. Friedrich PTACs oer programmable electronics with a large LED display that provides precise temperature control and energy savings. Installs thru-the-wall.
DUCTLESS SPLIT SYSTEMS
Sleek, absolutely quiet and incredibly energy ecient, with SEERs up to 19.0! Over 20 total system congurations, including nine dual, tri-zone and quad-zone wall-mounted congurations. Floor and ceiling models also available.
IDEAL FOR: Zone cooling or locations where no ductwork
exists, or is impossible or too costly to install. Any area where security is a concern.
VERTICAL SINGLE PACKAGE UNITS
Self contained unit installs in a small utility closet. A simpler way to condition multiple rooms. VERT-I-PAK installs as easily as a PTAC and the concealed installation creates a more homelike feel in a guest room or suite.
IDEAL FOR: Suites, extended stay properties, apartments
and dorms; or any application where lower sound levels are desired.
See the full line of Friedrich products @www.friedrich.com
Friedrich Air Conditioning Co. | P.O. Box 1540 | San Antonio, TX 78295-1540 | (800) 541-6645 | fax (210) 357-4480 | www.friedrich.com
RAC-08 (Revised 1-08) Printed in USA
Loading...