Friedrich Ccw06b10a Owner's Manual

CCW06B10A CCW08B10A CCW10B10A CCW12B10A CEW08B11A CEW12B33A
INTRODUCTION
IMPORTANT SAFETY INSTRUCTION ...........................................................................
ELECTRICAL REQUIREMENTS
PACKING LIST ............................................................................................................
INSTALLATION&ASSEMBLY INSTRUCTIONS ..............................................................
THROUGH-THE-WALL INSTALLATION INSTRUCTIONS................................................
USING YOUR AIR CONDITIONER ................................................................................
OPERATING YOUR AIR CONDITIONER
CARE AND CLEANING ................................................................................................
TROUBLESHOOTING .................................................................................................
...................................................................................
1
2
3
4
10
11
13
14
15
1
(6K cooling) 10A time-delay fuse or circuit breaker
(8K-12K cooling & 8K heating) 15A time-delay fuse or circuit breaker
(12K heating) 20A time-delay fuse or circuit breaker
6K/8K/10K/12K Cooling
8K Heating
12K Heating
2
3/8" Short Screws
5
1/2" Length Screws
3/4" Long Screws
5/8" Big Flat Head Bolt and Locknut
Sill Angel Bracket
1/2" Small Flat Head Bolt and Locknut
Chassis Lock
Support Bracket(with R and L remark)
Battery
3
4
3
2
4
ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’ S MANUAL ARE THE PRESENTATION OF THE MANUFACTURE. PLEASE READ AND FOLLOW THESE INSTRUCTIONS CAREFULLY.
Window preparation
1. This air conditioner is designed to be installed In a standard double-hung window with a window width between 23” and 36” (660mm-914mm).
2. The air conditioner can be installed without the accordion panels fit in a narrow window opening.
3. The lower sash ( the lower part of the window that moves up and down) must allow for 16” of vertical clearance when open.
4. All supporting parts must be secured to firm wood,
INTERIOR
WALL
STOOL SILL
Air conditioner
OFFSET
Bottom channel
EXTERIOR WALL
16
406mm
23” to 36”
660mm to 914mm
masonry, or metal.
5. The electrical outlet must be within reach of the power cord.
How to Install NOTE:This is necessary for proper condensed water utilization and drainage. If you are not using the Side Panels for any reason, this pitch to the rear muse be maintained!
Remove the air conditioner from the box and place on a hard flat surface, as floor, a bench or a table. There is a Left and Right Window Filler Panel - be sure to use the proper panel for each side. When installed the flange for securing the panel in place to the window sill will be facing into the room.