www.friedrich.comTHE EXPERTS IN ROOM AIR CONDITIONING
Page 2
THE NEXT GENERATION OF DUCTLESS SPLIT SYSTEMS
Advanced Inverter Ductless from Friedrich
ENERGY STAR® MODELS
Friedrich offers a wide variety of ENERGY STAR®
models in both single and multizone congurations with SEERS up to 28.0 and EERs up to 16.1.
Many utility companies offer rebates on ductless
systems. Contact your local energy provider or visit
http://www.dsireusa.org
INVERTER VARIABLE CAPACITY ADVANTAGES
Inverter technology allows each system to adjust
capacity output to provide only the amount of cooling needed at a given time. For example, an 18000
Btu system will operate even more efciently at
15500 Btu or less if that's all that’s needed, reducing energy consumption and improving comfort.
SOFT START TECHNOLOGY
Friedrich soft start technology starts the compres-
sor with signicantly reduced amperage at start
up, saving energy versus compressors utilizing
locked rotor amperage (LRA).
ZERO DUCT LOSS
The DOE reports that ducted systems lose an average of 25-40% in performance due to leaks, cracks
or disconnections in ductwork.
No ductwork means that ductless systems do not
experience duct loss, saving energy and money.
NO DIRTY AIR DUCTS*
Now there’s no need to clean dirty air ducts that
can harbor dust, germs and allergens that are
eventually blown into your home or ofce.
ZONE COOLING FLEXIBILITY
Independently condition up to eight (8) separate
zones using only a single outdoor unit. Achieve the
ultimate in comfort and energy control by cooling or heating only the zones that are in use. And,
because each zone is independent of the others,
comfort settings can vary.
OPTIMIZED AIRFLOW
The indoor unit's 4-way air swing quickly disperses
cool air to all four corners of the room to provide
comfort throughout the room within a few minutes.
The 'Surge Air' feature moves air at an even higher
speed for rapid cooling.
Protects the outdoor coil
against deterioration and
extends the life of the
unit especially in harsh
coastal environments.
*Ductless wall-mounted and ceiling cassette models
Model MWH09Y3JA
R
I
E
O
P
R
U
S
28.0 SEER
E
F
Y
C
F
N
I
C
E
I
2 | FRIEDRICH J SERIES DUCTLESS
Page 3
Heat and cool up to 8 zones utilizing wall-mounted,
™
ceiling cassette and The Insider
concealed ducted models.
Enjoy the exibility to mix and match systems
to t your application.
ZONE COOLING AND HEATING
PROVIDES UNMATCHED
CUSTOMIZED COMFORT AND
ENERGY SAVINGS
Occupants have the ability to set
the temperature of each zone to
their preferred comfort level*, or
turn off units in unoccupied rooms
without affecting other zones.
That’s the beauty and efciency of
a Friedrich Multizone System.
*Multizone units cannot heat and cool simultaneously.
3
Page 4
The Advantages of Friedrich's Precision Inverter System
Single or multizone, Friedrich ductless is superior to conventional systems
Precision Inverter technology varies
the compressor, the outdoor and
the indoor fan speeds, eliminating
constant compressor start-ups/shutdowns that traditional systems require
to maintain the set temperature.
Soft
start technology starts the compressor
with minimal amperage at start up,
saving energy versus compressors
utilzing locked rotor amperage (LRA).
This is especially beneficial in
multizone systems where room
temperature set points vary and some
indoor units may be turned off in
unoccupied rooms.
Each system can adjust capacity and
cooling output to provide only the
amount of cooling needed at a given
time. The result is optimal comfort
with low energy costs.
TRADITIONAL SYSTEMINVERTER SYSTEM
At initial start up, a xed capacity system
slowly reaches the set temperature.
Complete shutdown once set temperature
is achieved.
Temperature within the space rises until
2nd system start up.
System works at full capacity to again
reach set temperature.
System cycles on and off continually to
maintain the set temperature.
At initial start up, utilizes variable
capacity to quickly reach the set
temperature.
Reduces capacity as set temperature is achieved.
Variable capacity maintains set temperature keeping space comfortable
with reduced energy consumption.
The twin-rotary compressor and inverter drive provide superior performance
for perfect comfort and optimized energy efficiency.
Friedrich J Series ductless utilizes an
inverter drive coupled with variable
speed, twin rotary compressors for
optimal performance and increased
energy efficiency.
PRECISION
FEATUREADVANTAGEBENEFIT
Inverter DriveAccelerated cooling and heat-
ing performance
Variable Speed
Compressor
Inverter Soft
Start Technology
Inverter Long,
Slow Run
Twin-Rotary
Compressor
Smooth, modulated frquency
for temperature maintenance
Low rotation speed at startup keeping power current
minimal
No compressor start/stop like
conventional systems
Eliminates power spikes
that can affect appliances
and cause energy spikes
Energy used more effectively and system can
last longer
Highly efcient, low
noise, lowest vibration
4 | FRIEDRICH J SERIES DUCTLESS
Page 5
020
100806040
Friedrich Precision Inverter
56 Optimized Points
1 Hz Increments
Hz
Almost No Energy Wasted
Capacity
5
10
15
20
25
30
35
40
45
76
65
60
55
50
No other system matches the efciency and performance of
Friedrich's Precision Inverter
CONVENTIONAL SYSTEMS
Run at a single capacity, turning on and off to reach
the desired set point. This means they run at full speed
each time, resulting in high energy consumption.
100 % Capacity
Wasted Energy
Conventional On/Off System - 1 Optimized Point
020
Capacity
TWO-STAGE AIR CONDITIONERS
Won’t signicantly reduce your energy use. These units
only run at 2 speeds, 50% and 100%, also resulting in high
energy consumption.
100 % Capacity
Wasted
Energy
50 % Capacity
Wasted
Energy
100806040
0
Capacity
Two-Stage System (Low/High) - 2 Optimized points
20100806040
TYPICAL INVERTER SYSTEMS
Make changes in 7 Hz increments allowing the unit to run
at variable speeds, delivering a more precise heatingcooling solution.
Hz
76
65
60
55
50
45
40
35
30
25
20
15
10
5
0
Capacity
7 Hz Increments
Typical Inverter AC - 8 Optimized Points
20
Wasted Energy
100806040
FRIEDRICH PRECISION INVERTER SYSTEMS
Make changes in 1 Hz increments allowing the unit to run
at variable speeds, delivering the most precise heatingcooling solution.
5
Page 6
Attractive and high efciency options for cooling and
heating residential and light commercial spaces.
Wall-mounted models mount high on an exterior wall. The attractive, neutral nish blends
well with just about any decor. The units can be used individually or as part of a multizone
system to condition multiple spaces or a large area.
RESIDENTIAL APPLICATIONS
• Room additions/renovations
• Homes without ductwork
• Bedrooms and family rooms
• Garage workshops
• Sunrooms
• Guest quarters
COMMERCIAL APPLICATIONS
• Hotels and other lodging
• Computer rooms and server
rooms
• Restaurant kitchen and prep
areas
• Offices in warehouse spaces
• Multi-level office
• Storage facilities
• Buildings where security
concerns prevent the use of
window units
• Internal areas without
exterior wall access
6 | FRIEDRICH J SERIES DUCTLESS
Page 7
Super High Efciency and Zone Cooling Capability
With Friedrich Ductless Split Systems, you can cool and heat single or multiple rooms
more quietly and efciently than window air conditioners or traditional central air systems,
and without the expense of ductwork. You can control individual room temperatures, and
heat or cool only the areas that are occupied.
Many models qualify
Features for comfort and convenience
SMART AIRFLOW
Friedrich electronically controlled louvers direct air flow
upward for cooling and downward for heating to deliver
airflow where it’s needed most.
AUTO RESTART
Unit restarts at previous settings after power interruption.
ZONE COOLING FLEXIBILITY
Enjoy the ability to set room temperatures individually
when utilizing a multizone system.
CROSS FLOW FAN
The cross ow design of the indoor fan creates an ultraquiet, yet powerful air ow.
NO DIRTY AIR DUCTS
No ductwork means there is no ductwork that can harbor
dirt, dust and airborne allergens.
SURGE COOL/HEAT
When you want to cool down or heat up the room quickly,
this super high fan speed provides rapid cooling or
heating.
for rebates
Many utility companies
offer rebates on ductless air
conditioners. Contact your local
energy provider for information
on ductless rebates or visit:
http://www.dsireusa.org
Find a factory trained
Friedrich ductless installer
www.friedrich.com
at
AUTO CLEAN
Removes moisture from the indoor coil to help reduce
PRECISION
All Friedrich ductless split products require a licensed contractor for installation.
mold and musty odors
PRECISION INVERTER
Friedrich
cooling solution. It maintains the set temperature
without the constant on-off cycling of traditional systems
and outperforms standard inverter systems.
Precision Inverter
®
delivers a precise heating-
7
Page 8
Features you'll find with Friedrich Ductless Systems:
Wall-mounted
System Type
InstallationWallWallCeiling CeilingCeilingCeiling
Cool onlyYNNNNN
Heat pumpYYYYYY
115 volt cool only modelsYNNNNN
Inverter driven compressorYYYYYY
SEERUp to 28.0Up to 22.0Up to 19.0Up to 22.0Up to 17.6Up to 18.2
*Installation of an optional Low Ambient Wind Bafe Kit will allow operation down to 0°F in cooling mode.
†
HM09YJA and HM12YJA operate down to 0°F cooling and -13°F heating without wind bafe kit.
**Installation of an optional Low Ambient Wind Bafe Kit will allow operation down to -4°F in cooling mode.
AUTO CLEAN
Indoor blower runs to remove dust, dirt and moisture
from the coil after system is shutdown.
AUTO RESTART
Auto restart function allows system to resume with
previous settings in the event of a power shutdown.
(Power supply must be restored).
SURGE COOL/HEAT
Allows quick cooling/heating. In this mode, the unit will
operate at 100% for 30 minutes to cool/heat the room
rapidly.
DRY MODE
Reduces the humidity when cooling needs are low.
4-WAY AUTO SWING
BUILT-IN LOW AMBIENT STANDARD
Allows wall-mounted units to operate in temperatures
as low as 14º F in cooling mode (HM09YJA and HM12YJA
as low as 0º F). Concealed ducted and cassette models
can operate down to 5º F.
AUTO CHANGEOVER (SINGLE ZONE ONLY)
Automatically changes over from cool to heat and heat
to cool to maintain the set temperature.
Louvers will automatically move up/down and left /right to
maintain a uniform room temperature.
ADVANCED CORROSION PROTECTION
Protects the outdoor coil against deterioration and
extends the life of the unit especially in harsh coastal
environments.
8 | FRIEDRICH J SERIES DUCTLESS
Page 9
The indoor cross-flow fan and a low vibration compressor provide ultra
quiet operation indoors and outdoors.
ULTRA QUIET CROSS-FLOW FAN
An electronically controlled cross-ow fan creates
an ultra quiet, yet powerful air ow into the room.
LOW VIBRATION, TWIN-ROTARY
COMPRESSOR
Friedrich's twin-rotary compressor has a unique
design that reduces vibration for lower sound
levels outdoors.
BLDC FAN MOTOR
Brushless, digitally commutated motor with
accurate speed control that makes the electrical
and mechanical operation smoother, more reliable
and more efcient.
Friedrich
Low Fan
Friedrich
Sleep Mode
17
Whisper
Concert
Central Air
35
24
decibels dB(A)
35152460
Library
Hall
Typical Window
Air Conditioner
60
Normal
Conversation
Powerful airflow for faster heating and cooling.
OPTIMUM AIR FLOW
Air is directed downward in heating mode and angled
upward during cooling mode so the room feels more
comfortable, faster.
LARGE FANS
Powerful fans move the air across the room- up to 39
feet away. That means faster cooling and heating and
you feel comfortable sooner no matter where you are
in the room.
9
Page 10
Convenient installation features that will get your
ductless running in no time.
A SET OF
16 INCH ON-CENTER HOLES
Model MW12C1J indoor unit and hanging bracket shown.
Bracket appearance will vary by model.
UNIQUE MOUNTING BRACKET
16" ON-CENTER
The hanging bracket comes with a set of holes
that are placed 16” apart from each other to
help you attach the bracket securely to "16 on
center" wall studs.
LEVEL-LINE LEDGES
Incorporated “Level-Line Ledges” ensure a
straight wall mount and frees both hands for
an easy single-person installation.
TAPE MEASURE ASSIST*
The integrated “blade grip” securely keeps
measuring tape in place. The ”blade grip”
gives you a helping hand when installing the
bracket to the wall.
*Not on models HM09YJA, HM12YJA.
WALL STAND-OFF BRACKET
The clip keeps sufcient space between the unit
and the wall creating more room for installation.
Feature varies by model.
SPACIOUS TUBING AREA
Ample space was created to facilitate tubing
installation and placement.
10 | FRIEDRICH J SERIES DUCTLESS
Page 11
OPTIONAL ACCESSORIES
REFRIGERATION LINE SETS (REQUIRED ACCESSORY)
Kit#
T3215015’1/4”3/8”
T3235035’1/4”3/8”
T4215015’1/4”1/2”
T4235035’1/4”1/2”
T5315015’3/8”5/8”
T5335035’3/8”5/8”
Ft.Liquid Suction
LOW AMBIENT WIND BAFFLE KIT*
Length
Wind bafe allows operation down to O°FWB on single zone heat pumps, and
down to -4°FWB on Multizone units.
*Models HM09YJA and HM12YJA operate down to O°FWB without a bafe kit.
WIND BAFFLEUSED WITH
DLAWB19000 - 12000 Btu wall-mounted single zone models
DLAWB218000 - 36000 Btu wall-mounted single zone models
DLAWB324000-36000 Btu Multizone
DLAWB4*48000 Btu Multizone
* 48000 Btu Multizone requires 2 wind bafe kits.
VENTILATION KIT
Ventilation kit allows conditioned fresh air to be brought directly into the unit.
• Built-in low ambient standard, down to 14ºF
(Cooling mode) down to 0º F with optional
wind baffle
• 24-hour on/off timer
• Wall stand-off bracket
*Models M18CJ, and components MW18C3J, MR18C3J,
are not available for sale in AZ, CA, NM or NV.
115 volt models
MW09C1J, MW12C1J
MW18C3J
12 | FRIEDRICH J SERIES DUCTLESS
MR09C1J, MR12C1J MR18C3J
PARTS
WARRANTY
COMPRESSOR
WARRANTY
PRECISION
Page 13
SPECIFICATIONS
PERFORMANCE RATINGSSingle Zone Wall-Mounted - Cool Only
9k12k18k
SYSTEM MODEL NO.
INDOOR MODELMW09C1JMW12C1JMW18C3J*
OUTDOOR MODELMR09C1JMR12C1JMR18C3J*
SPECIFICATIONS
CAPACITY COOLING (RATED)Btu9,00010,60017,000
CAPACITY COOLING (MIN~MAX)Btu3,070~12,1203,070~13,6603,070~20,470
COOLING AMPS67.36.3
SENSIBLE HEAT RATIO.71.71.72
SEER21.521.518.0
EER13.313.012.0
ENERGY STARYESYESNO
MOISTURE REMOVALPts/h2.32.74.2
AIRFLOW (QUIET, LOW, MED, HIGH)CFM124/212/272/335124/212/272/335300/371/441/512
SOUND RATING - INDOORdB-A19 / 24 / 33 / 3819 / 24 / 33 / 3929 / 35 / 40 / 45
SOUND RATING - OUTDOORdB-A454553
OPERATING RANGE ( 0°F WITH WIND BAFFLE)°FDB14(0)~11814(0)~11814(0)~118
EST. YEARLY OPERATING COST $6181127
ELECTRICAL DATA
POWER SOURCEV115/60/1115/60/1208/230/60/1
MINIMUM AMPACITYA121219
COOLING WATTSW6778151417
MAX. TD FUSE/BREAKERA202025
POWER AND COMMUNICATION CABLE
REFRIGERATION SYSTEM
REFRIGERANTR410AR410AR410A
COMPRESSOR TYPESingle RotarySingle RotaryTwin Rotary
CONNECTIONSFlareFlareFlare
LIQUID LINE O.D.in1/41/41/4
SUCTION LINE O.D.in3/83/81/2
FACTORY PRECHARGEft414125
REFRIGERANT CHARGEoz363648
MIN./MAX. LINE LENGTHft7~667~6610~66
MAX. HEIGHT DIFFERENCEft333333
DIMENSIONS & WEIGHT
INDOOR UNIT
W X H X Din
NET WEIGHTlbs232332
SHIPPING WEIGHTlbs272740
OUTDOOR UNIT
W X H X Din
NET WEIGHTlbs787897
SHIPPING WEIGHTlbs7979101
TOTAL NET WEIGHTlbs101101129
TOTAL SHIPPING WEIGHTlbs106106169
No. x AWG
M09CJM12CJM18CJ*
4 x 144 x 144 x 14
35-1/4 x 11-1/4 x 8-5/1640-5/8 x 12-7/8 x 9-5/8
30-5/16 x 21-5/16 x 11-5/1634-5/16x 25-7/8 x12-5/8
*Models M18CJ and components MW18C3J and MR18C3J are not available for sale in AZ, CA, NM or NV.
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .12 per kWh.
For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
13
Page 14
HEAT PUMPS
Single Zone Wall-mounted
9000 & 12000 Btu. Top cooling and heating performance in extreme climates.
• Low ambient operation down to 0º F
(Cooling mode)
• Low ambient operation down to -13º F
(Heating mode)
WIRELESS
REMOTE CONTROL
14 | FRIEDRICH J SERIES DUCTLESS
MRH09Y3JA, MRH12Y3JA
PARTS
WARRANTY
COMPRESSOR
WARRANTY
PRECISION
Page 15
SPECIFICATIONS
PERFORMANCE RATINGSSingle Zone Wall-Mounted - Heat Pumps
9k12k
SYSTEM MODEL NO.HM09YJAHM12YJA
INDOOR MODELMWH09Y3JAMWH12Y3JA
OUTDOOR MODELMRH09Y3JAMRH12Y3JA
SPECIFICATIONS
CAPACITY COOLING (RATED)Btu9,00012,000
CAPACITY COOLING (MIN~MAX)Btu3600-100004000-13500
@
CAPACITY HEATING
CAPACITY HEATING
CAPACITY HEATING (MIN~MAX)Btu3600-105004000-14000
COOLING AMPS2.34.6
HEATING AMPS3.44.8
SENSIBLE HEAT RATIO0.850.85
SEER28.025.0
EER16.115.5
HSPF12.512.0
ENERGY STARYes Ye s
MOISTURE REMOVALPts/h1.90 2.54
AIRFLOW (QUIET, LOW, MED, HIGH)CFM416/384/355/279598/536/446/345
SOUND RATING - INDOORdB-A 39/34/31/2845/41/39/36
SOUND RATING - OUTDOORdB-A 5555
OPERATING RANGE (COOLING)°F0˚-115˚0˚-115˚
OPERATING RANGE (HEATING)°F-13˚-75˚-13˚-75˚
EST. YEARLY OPERATING COST $
ELECTRICAL DATA
POWER SOURCEV208/230/60/1208/230/60/1
MINIMUM AMPACITYA10A12A
COOLING WATTSW560775
HEATING WATTSW770850
MAX. TD FUSE/BREAKERA1515
POWER AND COMMUNICATION CABLE
REFRIGERATION SYSTEM
REFRIGERANTR410AR410A
COMPRESSOR TYPERotaryRotary
CONNECTIONSFlareFlare
LIQUID LINE O.D.in1/41/4
SUCTION LINE O.D.in3/83/8
FACTORY PRECHARGEft24.624.6
REFRIGERANT CHARGEoz38.845.9
MIN./MAX. LINE LENGTHft65.465.4
MAX. HEIGHT DIFFERENCEft16.416.4
DIMENSIONS & WEIGHT
INDOOR UNIT
W X H X Din 32 7/8 x 11 x 8 11/1636 x 12 3/8 x 9 5/16
NET WEIGHTlbs19.828.6
SHIPPING WEIGHTlbs24.233.0
OUTDOOR UNIT
W X H X Din31 7/8 x 23 x 1131 7/8 x 23 x 11
NET WEIGHTlbs72.672.6
SHIPPING WEIGHTlbs79.279.2
TOTAL NET WEIGHTlbs92.4101.2
TOTAL SHIPPING WEIGHTlbs103.4112.2
470F (RATED)Btu10,71512,957
@
170F (RATED)Btu6,4338,030
No. x AWG
4 x 144 x 14
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .12 per kWh.
For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology,
specications are subject to change without notice.
15
Page 16
HEAT PUMPS
Single Zone Wall-mounted
18000 - 36000 Btu. Features for comfort and convenience year 'round. In heating
mode, units use approximately 1/4 of the energy required by electric heat.
• Built-in low ambient standard, down to 14º
F (Cooling mode), down to 0º F with wind
baffle
• Low ambient operation down to -4º F
(Heating mode)
• 24-hour on/off timer
MW18Y3J, MW24Y3J, MW36Y3J
WIRELESS
REMOTE CONTROL
16 | FRIEDRICH J SERIES DUCTLESS
MR18Y3J, MR24Y3J, MR36Y3J
PARTS
WARRANTY
COMPRESSOR
WARRANTY
PRECISION
Page 17
SPECIFICATIONS
PERFORMANCE RATINGSSingle Zone Wall-Mounted - Heat Pumps
18k24k36k
SYSTEM MODEL NO.M18YJM24YJM36YJ
INDOOR MODELMW18Y3JMW24Y3JMW36Y3J
OUTDOOR MODELMR18Y3JMR24Y3JMR36Y3J
SPECIFICATIONS
CAPACITY COOLING (RATED)Btu17,00022,00033,000
CAPACITY COOLING (MIN~MAX)Btu3,070~20,4703,070~30,0303,070~34,000
@
CAPACITY HEATING
CAPACITY HEATING @170 F (RATED)Btu13,20017,90023,200
CAPACITY HEATING (MIN~MAX)Btu3,070~30,7003,070~38,8983,070~38,900
COOLING AMPS77.917.0
HEATING AMPS7.310.716.2
SENSIBLE HEAT RATIO.73.72.78
SEER18.021.517.5
EER12.012.58.15
HSPF9.711.0 10.0
ENERGY STARYESYESNo
MOISTURE REMOVALPts/h4.25.56.5
AIRFLOW (QUIET, LOW, MED, HIGH)CFM300/371/441/512300/389/512/600459/530/706/848
SOUND RATING - INDOORdB-A29 / 35 / 40 / 45 33 / 39 / 43 / 4637 / 40 / 44 / 49
SOUND RATING - OUTDOORdB-A 535455
OPERATING RANGE COOLING (WIND BAFFLE)°F14(0)~11814(0)~11814(0)~118
OPERATING RANGE HEATING°F-4~75-4~75-4~75
EST. YEARLY OPERATING COST $127158395
ELECTRICAL DATA
POWER SOURCEV230/208/60/1208/230/60/1230/208/60/1
MINIMUM AMPACITYA191919
COOLING WATTSW141617604024
HEATING WATTSW168023803840
MAX. TD FUSE/BREAKERA203535
POWER AND COMMUNICATION CABLE
REFRIGERATION SYSTEM
REFRIGERANTR410AR410AR410A
COMPRESSOR TYPETwin RotaryTwin RotaryTwin Rotary
CONNECTIONSFlareFlareFlare
LIQUID LINE O.D.in1/43/83/8
SUCTION LINE O.D.in1/25/85/8
FACTORY PRECHARGEft252525
REFRIGERANT CHARGEoz487878
MIN./MAX. LINE LENGTHft10~6610~16410~164
MAX. HEIGHT DIFFERENCEft339898
DIMENSIONS & WEIGHT
INDOOR UNIT
W X H X Din 40-5/8 x 12-7/8 x 9-5/846-7/8 x 13-5/8 x10-3/846-7/8 x 13-5/8 x 10-3/8
NET WEIGHTlbs314040
SHIPPING WEIGHTlbs404646
OUTDOOR UNIT
W X H X Din34-5/16 x 25-7/8 x 12-5/834-5/16 x 31-1/2 x12-5/834-5/16 x 31-1/2 x12-5/8
NET WEIGHTlbs97125125
SHIPPING WEIGHTlbs101132132
TOTAL NET WEIGHTlbs128165165
TOTAL SHIPPING WEIGHTlbs141178178
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .12 per kWh.
For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology,
specications are subject to change without notice.
470 F (RATED)Btu20,20027,00035,200
No. x AWG
4 x 144 x 144 x 14
17
Page 18
HEAT PUMPS
Single Zone Ceiling Cassette
24000 and 36000 Btu. Indoor units are typically installed in a drop ceiling.
The unit mounts flush to the ceiling for a clean look and efficient installation.
• Internal condensate pump
with 27 1/2" lift* included
• Natural air flow
• 4-Way cooling
• Surge Cool/Heat
• Cooling/Heating/Fan mode
• Dry mode
• Sleep mode
• Built-in low ambient
standard, down to 5º F
(Cooling mode)
• Low ambient operation down
to -4º F (Heating mode)
• Independent vane control
• * Lift from drain pan to the highest point 27 1/2"
• 3 Fan speeds
• Evaporator frost control
• 24-hour on/off timer
• Auto restart
• Auto changeover
• Temperature display on
remote
• Ultra-quiet turbo fan
• DiamonGold Advanced
Corrosion Protection™
• Clean, modern look
• Flexible installation
• ENERGY STAR
models
• Precise air distribution
• Capable of branch duct to
adjacent closet or bathroom
®
qualified
Low prole indoor unit is
recessed into the ceiling for a
clean look and greater clearance.
NOTE: Grilles are sold separately.
See optional accessories on page 11.
MC36Y3J
WIRELESS
REMOTE CONTROL
18 | FRIEDRICH J SERIES DUCTLESS
MC24Y3J
MR24UY3J MR36UY3J
PARTS
WARRANTY
COMPRESSOR
WARRANTY
PRECISION
Page 19
SPECIFICATIONS
PERFORMANCE RATINGSSingle Zone Cassette - Heat Pumps
24k36k
SYSTEM MODEL NO.C24YJC36YJ
INDOOR MODELMC24Y3JMC36Y3J
OUTDOOR MODELMR24UY3JMR36UY3J
SPECIFICATIONS
CAPACITY COOLING (RATED)Btu24,00036,000
CAPACITY COOLING (MIN~MAX)Btu9,700~26,70014,000~42,000
@
CAPACITY HEATING
CAPACITY HEATING @170 F (RATED)Btu18,60026,000
CAPACITY HEATING (MIN~MAX)Btu10,900~30,00014,500~45,000
COOLING AMPS15.120.2
HEATING AMPS16.024.0
SENSIBLE HEAT RATIO.77.76
SEER17.019.0
EER12.613.5
HSPF9.79.5
ENERGY STAR *Ye sYes
MOISTURE REMOVALPts/h5.1 7.7
AIRFLOW (LOW, MED, HIGH )CFM459 / 530 / 600918 / 989 / 1,060
SOUND RATING - INDOOR H/M/LdB(A)38/36/3446/44/43
SOUND RATING - OUTDOORdB(A)6267
OPERATING RANGE (COOLING)°FDB5~1185~118
OPERATING RANGE (HEATING)°FWB-4~64-4~64
EST. YEARLY OPERATING COST $172240
ELECTRICAL DATA
POWER SOURCEV208/230/60/1208/230/60/1
MINIMUM AMPACITYA18.124.5
COOLING WATTSW19102970
MAX. TD FUSE/BREAKERA3040
POWER AND COMMUNICATION CABLE
REFRIGERATION SYSTEM
REFRIGERANTR410AR410A
COMPRESSOR TYPETwin RotaryTwin Rotary
CONNECTIONSFlareFlare
LIQUID LINE O.D.in3/83/8
SUCTION LINE O.D.in5/85/8
FACTORY PRECHARGEft2525
REFRIGERANT CHARGEoz71120
MIN./MAX. LINE LENGTHft25~16425~246
MAX. HEIGHT DIFFERENCEft9898
DIMENSIONS & WEIGHT
INDOOR UNIT
W X H X Din 33-1/16 x 8-1/16 x 33-1/1633-1/16 x 11-3/8 x 33-1/16
NET WEIGHTlbs4554
SHIPPING WEIGHTlbs5865
INDOOR UNIT GRILLE** W X H X Din 37-3/8 x 15/16 x 37-3/837-3/8 x 15/16 x 37-3/8
INDOOR UNIT GRILLE** NET WEIGHTlbs1111
OUTDOOR UNIT
W X H X Din37-7/16 x 32-7/8 x 1337-13/32 x 54-3/8 x 13
NET WEIGHTlbs132203
SHIPPING WEIGHTlbs146227
TOTAL NET WEIGHTlbs178257
TOTAL SHIPPING WEIGHTlbs203293
470 F (RATED)Btu27,00040,000
No. x AWG
4 x 144 x 14
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .12 per kWh.
For more information, visit www.ftc.gov/energy.
*System meets ENERGY STAR® published minimums.
**Models require grille. Sold separately.
Due to continuing research in new energy-saving technology,
specications are subject to change without notice.
19
Page 20
HEAT PUMPS
Single Zone The Insider™ Concealed Ducted
24000 and 36000 Btu. Indoor unit is installed in the
ceiling or furr down for unobtrusive installation.
• Internal condensate pump with
27 1/2" lift* included
• Cooling/Heating/Fan mode
• Built-in low ambient standard, down to 5º F
(Cooling mode)
• Low ambient operation down to -4º F
(Heating mode)
• Dry mode
• 3 Fan speeds
• Auto restart
• Auto changeover
• Control lock function on controller
• External Static Pressure Range (ESP)
- 24,000 (0.1 - 0.78) WC
- 36,000 (0.15 - 0.6) WC
MD24Y3J, MD36Y3J
* Lift from drain pan to highest point 27 1/2"
WIRED WALL
CONTROLLER
20 | FRIEDRICH J SERIES DUCTLESS
MR24UY3J MR36UY3J
PARTS
WARRANTY
COMPRESSOR
WARRANTY
PRECISION
Page 21
SPECIFICATIONS
PERFORMANCE RATINGSSingle Zone - The Insider™ Concealed Ducted Heat Pumps
24k36k
SYSTEM MODEL NO.D24YJD36YJ
INDOOR MODELMD24Y3JMD36Y3J
OUTDOOR MODELMR24UY3JMR36UY3J
SPECIFICATIONS
CAPACITY COOLING (RATED)Btu24,00036,000
CAPACITY COOLING (MIN~MAX)Btu9,700~26,70016,000~41,400
@
CAPACITY HEATING
CAPACITY HEATING @170F (RATED)Btu17,60024,600
CAPACITY HEATING (MIN~MAX)Btu10,900~30,00017,500~48,000
COOLING AMPS15.120.8
HEATING AMPS15.121.4
SENSIBLE HEAT RATIO.68.67
SEER17.017.6
EER12.012.1
HSPF10.09.2
ENERGY STARNoNo
MOISTURE REMOVALPts/h7.010.6
AIRFLOW (LOW, MED, HIGH )CFM530 / 618 / 688706 / 953 / 1,130
SOUND RATING - INDOOR H/M/LdB(A)38/36/3539/38/37
SOUND RATING - OUTDOORdB(A)6267
OPERATING RANGE (COOLING)°F5~1185~118
OPERATING RANGE (HEATING)°F-4~64-4~64
EST. YEARLY OPERATING COST $180268
ELECTRICAL DATA
POWER SOURCE208/230/60/1208/230/60/1
MINIMUM AMPACITYA18.124.5
COOLING WATTSW20002910
MAX. TD FUSE/BREAKERA3040
POWER AND COMMUNICATION CABLE
REFRIGERATION SYSTEM
REFRIGERANTR410AR410A
COMPRESSOR TYPETwin RotaryTwin Rotary
CONNECTIONSFlareFlare
LIQUID LINE O.D.in3/83/8
SUCTION LINE O.D.in5/85/8
FACTORY PRECHARGEft2525
REFRIGERANT CHARGEoz71120
MIN./MAX. LINE LENGTHft25~16425~246
MAX. HEIGHT DIFFERENCEft9898
DIMENSIONS & WEIGHT
INDOOR UNIT
W X H X Din 46-9/16 x 11-3/4 x 17-3/448-1/2 x 15 x 23-1/4
NET WEIGHTlbs73125
SHIPPING WEIGHTlbs95139
OUTDOOR UNIT
W X H X Din37-7/16 x 32-7/8 x 1337-7/16 x 54-3/8 x 13
NET WEIGHTlbs132203
SHIPPING WEIGHTlbs146227
TOTAL NET WEIGHTlbs205327
TOTAL SHIPPING WEIGHTlbs240366
470F (RATED)Btu27,00040,000
No. x AWG
4 x 144 x 14
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .12 per kWh.
For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology,
specications are subject to change without notice.
21
Page 22
HEAT PUMPS
Multizone Wall-mounted
High efficiency heat pumps with features for comfort and convenience year
'round. In heating mode, units use approximately 1/4 of the energy required by
electric heat.
7k9k12k18k
INDOOR MODELMW07Y3JMMW09Y3JMW12Y3JMW18Y3J
SPECIFICATIONS
CAPACITY COOLING (RATED)Btu7,0009,00011,20017,000
CAPACITY HEATING (RATED)Btu8,10010,80013,30020,200
MOISTURE REMOVALPts/hNA2.32.74.2
AIRFLOW (QUIET, LOW, MED, HIGH)CFM162/177/198124/212/272/335124/212/272/335300/399/509/622
SOUND RATING - INDOORdB-A 26/30/3319 / 24 / 33 / 3819 / 24 / 33 / 3929 / 35 / 40 / 45
ELECTRICAL DATA
POWER SOURCEV, Ø, Hz230/208-60-1230/208-60-1230/208-60-1230/208-60-1
REFRIGERATION SYSTEM
CONNECTIONSFlareFlareFlareFlare
LIQUID LINE O.D.in1/41/41/41/4
SUCTION LINE O.D.in3/83/83/81/2
DIMENSIONS & WEIGHT
W X H X Din 34-7/8 x11-1/4 x 8-1/435-1/4 x11-1/4 x 8-1/4 35-1/4 x 11-1/4 x 8-1/4 40-5/8 x 12-7/8 x 9-5/8
NET WEIGHTlbs20232331
SHIPPING WEIGHTlbs26272740
PERFORMANCE RATINGSMulti Outdoor
24k36k48k
OUTDOOR MODELMR24DY3JMAMR36TQY3JMAMR48DEY3JM
SPECIFICATIONS
POWER SOURCE208/230/60/1208/230/60/1208/230/60/1
EST. YEARLY OPERATING COST$122~125170~245346~400
RUNNING CURRENT COOLING MIN.~RATED~MAX.A1.7~6.4~9.02.9~10.7~15.74.6~16.7~24.8
RUNNING CURRENT HEATING MIN.~RATED~MAX.A1.8~7.8~11.23.3~11.9~18.36.2~18.8~26.2
POWER INPUT COOLING MIN.~RATED~MAX.W390~1480~2070670~2460~3610970~3840~5710
POWER INPUT HEATING MIN.~RATED~MAX.W420~1800~2580760~2740~42101420~4320~6020
POWER AND COMMUNICATION CABLENo. x AWG4 X 144 X 144 X 14
DIMENSIONS W X H X Dinch
NET WEIGHTlbs99137214
SHIPPING WEIGHTlbs139148236
REFRIGERATION SYSTEM
REFRIGERANTR410AR410AR410A
FACTORY PRECHARGEft7498Main: 16.4, Branch 131.2
LIQUID LINE O.D.in1/41/43/8
SUCTION LINE O.D.in3/83/83/4
MIN./MAX. LINE LENGTH (EACH)ft10~8210~8210~49*
MIN./MAX. LINE LENGTH (TOTAL)ft75~24675~24630~476*
MAX. HEIGHT DIFFERENCEft494998*
SOUND PRESSURE LEVEL COOLINGA515254
SOUND PRESSURE LEVEL HEATINGA515556
OPERATING RANGE COOLING (WIND BAFFLE) °F DB14 (-4) ~ 11814 (-4) ~ 11814 (-4) -118
OPERATING RANGE HEATING°F WB-4 ~ 64-4 ~ 64-4 ~ 64
MINIMUM AMPACITYA14.317.927.3
MAX. TD FUSE/BREAKERA202540
34-1/4 x 25-3/4 x12-5/837-7/16 x 32-7/8 x 15 1/237-3/8 × 54-5/16 × 13
*System requires branch box D4PBB. See page 33 for piping guidelines. For branch box to indoor line sizes, please see Indoor System Components Chart.
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .12 per kWh.
For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
23
Page 24
HEAT PUMPS
Multizone Ceiling Cassette
Indoor units are typically installed in a drop ceiling. The grille fits almost flush
with the ceiling for a clean look and efficient installation.
FEATURES
• Inverter technology (variable
speed compressor)
• Soft start compressor
• Internal condensate pump
• Evaporator frost control
• 24-hour on/off timer
• Auto restart
• Temperature display on
with 23" lift* included
• Natural air flow
• 4-Way cooling
• Ultra-quiet turbo fan
• DiamonGold Advanced
• Cooling/Heating/Fan mode
• Dry mode
• Night Quiet Operation
• Built-in low ambient
• Clean, modern look
• Flexible installation
• ENERGY STAR
standard, down to 14º F
(Cooling mode)
• Low ambient operation,
• Precise air distribution
• Capable of branch duct to
down to -4º F (Heating mode)
12k18k
INDOOR MODELMC12Y3JMMC18Y3JM
SPECIFICATIONS
CAPACITY COOLING (RATED)Btu12,00018,000
CAPACITY HEATING (RATED)Btu13,80019,000
MOISTURE REMOVALPts/h4.24.2
AIRFLOW ( LOW, MED, HIGH)CFM 247 / 283 /335388 / 424 / 459
SOUND RATING - INDOORdB-A 32/35/3834/37/38
ELECTRICAL DATA
POWER SOURCEV, Ø, Hz208/230, 1, 60208/230, 1, 60
POWER AND COMMUNICATION CABLENo. x AWG4 x 144 x 14
REFRIGERATION SYSTEM
CONNECTIONSFlareFlare
LIQUID LINE O.D.in1/41/4
SUCTION LINE O.D.in3/81/2
DIMENSIONS & WEIGHT
W X H X Din 22-7/16 x 8-7/16 x 22-7/1622-7/16 x 10-3/32 x 22-7/16
NET WEIGHTlbs3133
SHIPPING WEIGHTlbs3642
INDOOR UNIT GRILLE* W X H X Din 27-9/16 x 7/8 x 27-9/1627-9/16 x 7/8 x 27-9/16
INDOOR UNIT GRILLE* NET WEIGHTlbs77
PERFORMANCE RATINGSMulti Outdoor
24k36k48k
OUTDOOR MODELMR24DY3JMAMR36TQY3JMAMR48DEY3JM
SPECIFICATIONS
POWER SOURCE208/230/60/1208/230/60/1208/230/60/1
EST. YEARLY OPERATING COST$122~125170~245346~400
RUNNING CURRENT COOLING MIN.~RATED~MAX.A1.7~6.4~9.02.9~10.7~15.74.6~16.7~24.8
RUNNING CURRENT HEATING MIN.~RATED~MAX.A1.8~7.8~11.23.3~11.9~18.36.2~18.8~26.2
POWER INPUT COOLING MIN.~RATED~MAX.W390~1480~2070670~2460~3610970~3840~5710
POWER INPUT HEATING MIN.~RATED~MAX.W420~1800~2580760~2740~42101420~4320~6020
POWER AND COMMUNICATION CABLENo. x AWG4 X 144 X 144 X 14
DIMENSIONS W X H X Dinch
NET WEIGHTlbs99137214
SHIPPING WEIGHTlbs139148236
REFRIGERATION SYSTEM
REFRIGERANTR410AR410AR410A
FACTORY PRECHARGEft7498Main: 16.4, Branch 131.2
LIQUID LINE O.D.in1/41/43/8
SUCTION LINE O.D.in3/83/83/4
MIN./MAX. LINE LENGTH (EACH)ft10~8210~8210~49*
MIN./MAX. LINE LENGTH (TOTAL)ft75~24675~24630~475*
MAX. HEIGHT DIFFERENCEft494998*
SOUND PRESSURE LEVEL COOLINGA515254
SOUND PRESSURE LEVEL HEATINGA515556
OPERATING RANGE COOLING (WIND BAFFLE) °F DB14 (-4) ~ 11814 (-4) ~ 11814 (-4) -118
OPERATING RANGE HEATING°F WB-4 ~ 64-4 ~ 64-4 ~ 64
MINIMUM AMPACITYA14.317.927.3
MAX. TD FUSE/BREAKERA202540
34-1/4 x 25-3/4 x12-5/837-7/16 x 32-7/8 x 15 1/237-3/8 × 54-5/16 × 13
*System requires branch box D4PBB. See page 33 for piping guidelines. For branch box to indoor line sizes, please see Indoor System Components Chart
**Models require grille. Grille sold separately.
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .12 per kWh. For more
information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology,
specications are subject to change without notice.
25
Page 26
HEAT PUMPS
Multizone The Insider™ Concealed Ducted
Indoor unit is installed in the ceiling or furr down for unobtrusive installation.
Conditioned or non-conditioned air can be added to ducting to allow fresh air
into the conditioned space whenever required.
FEATURES
• Inverter technology (variable speed
compressor)
• Soft start compressor
• Internal condensate pump with
23" lift* included
• Cooling/Heating/Fan mode
• Dry mode
• 3 Fan speeds
• Auto restart
• Control lock function
• External Static Pressure Range (ESP)
- 9,000 ( 0.0 - 0.20) WC
- 12,000 ( 0.0 - 0.20) WC
- 18,000 ( 0.0 - 0.20) WC
* Lift from drain pan to the highest point. Use external drain
pump for installations requiring condensate lift exceeding 23"
WIRED WALL
CONTROLLER
MR24DY3JMA MR36TQY3JMA MR48DEY3JM
MD09Y3JM, MD12Y3JM, MD18Y3JM
26 | FRIEDRICH J SERIES DUCTLESS
PARTS
WARRANTY
COMPRESSOR
WARRANTY
PRECISION
Page 27
SPECIFICATIONS
PERFORMANCE RATINGSMultizone - The Insider™ Concealed Ducted Heat Pumps
9k12k18k
INDOOR MODELMD09Y3JMMD12Y3JMMD18Y3JM
SPECIFICATIONS
CAPACITY COOLING (RATED)Btu9,00012,00018,000
CAPACITY HEATING (RATED)Btu10,40013,80019,000
MOISTURE REMOVALPts/h2.52.54.2
AIRFLOW ( LOW, MED, HIGH)CFM194 / 247 / 318 265 / 300 / 335406 / 477 / 530
SOUND RATING - INDOORdB-A 30 / 26 / 2326/31/3329/31/34
ELECTRICAL DATA
POWER SOURCE208/230, 1, 60208/230, 1, 60208/230, 1, 60
POWER AND COMMUNICATION CABLENo. x AWG4 x 144 x 144 x 14
REFRIGERATION SYSTEM
CONNECTIONSFlareFlareFlare
LIQUID LINE O.D.in1/41/41/4
SUCTION LINE O.D.in3/83/81/2
DIMENSIONS & WEIGHT
W X H X Din
NET WEIGHTlbs394558
SHIPPING WEIGHTlbs455165
PERFORMANCE RATINGSMulti Outdoor
OUTDOOR MODELMR24DY3JMAMR36TQY3JMAMR48DEY3JM
SPECIFICATIONS
POWER SOURCE208/230/60/1208/230/60/1208/230/60/1
EST. YEARLY OPERATING COST$122~125170~245346~400
RUNNING CURRENT COOLING MIN.~RATED~MAX.A1.7~6.4~9.02.9~10.7~15.74.6~16.7~24.8
RUNNING CURRENT HEATING MIN.~RATED~MAX.A1.8~7.8~11.23.3~11.9~18.36.2~18.8~26.2
POWER INPUT COOLING MIN.~RATED~MAX.W390~1480~2070670~2460~3610970~3840~5710
POWER INPUT HEATING MIN.~RATED~MAX.W420~1800~2580760~2740~42101420~4320~6020
POWER AND COMMUNICATION CABLENo. x AWG4 X 144 X 144 X 14
DIMENSIONS W X H X Dinch
NET WEIGHTlbs99137214
SHIPPING WEIGHTlbs139148236
REFRIGERATION SYSTEM
REFRIGERANTR410AR410AR410A
FACTORY PRECHARGEft7498Main 16.4, Branch 131.2
LIQUID LINE O.D.in1/41/43/8
SUCTION LINE O.D.in3/83/83/4
MIN./MAX. LINE LENGTH (EACH)ft10~8210~8210~49*
MIN./MAX. LINE LENGTH (TOTAL)ft75~24675~24630~475*
MAX. HEIGHT DIFFERENCEft494998*
SOUND PRESSURE LEVEL COOLINGA515254
SOUND PRESSURE LEVEL HEATINGA515556
OPERATING RANGE COOLING (WIND BAFFLE) °F DB14 (-4) ~ 11814 (-4) ~ 11814 (-4) -118
OPERATING RANGE HEATING°F WB-4 ~ 64-4 ~ 64-4 ~ 64
MINIMUM AMPACITYA14.317.927.3
MAX. TD FUSE/BREAKERA202540
30-15/32 x 7-15/32 x 27
34-1/4 x 25-3/4 x12-5/837-7/16 x 32-7/8 x 15 1/237-3/8 × 54-5/16 × 13
-
9/16
32-9/32 x 7-15/32 x 22-5/843-5/16 x 7-15/32 x 22-5/8
24k36k48k
*System requires branch box D4PBB. See page 33 for piping guidelines. For branch box to indoor line sizes, please see Indoor System Components Chart.
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .12 per kWh. For more
information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
27
Page 28
MULTIZONE CONFIGURATION GUIDELINES
Mix-and-match a combination of indoor units that does not exceed the
maximum connected capacity, and is within the recommended parameters:
Wall-mounted
Ceiling Cassette
12,000
18,000
MR24DY3JMA
33,000 Btu MAX.
CONNECTED
CAPACITY
7,000
9,000
12,000
18,000
MR36TQY3JMA
48,000 Btu MAX.
CONNECTED
CAPACITY
The Insider™
9,000
12,000
18,000
MR48DEY3JM
65,000 Btu MAX.
CONNECTED
CAPACITY
MR24DY3JMA:
FOR (2) ZONES:
Minimum combination must be 50% of
nameplate capacity
FOR (3) ZONES:
Select any combination of (3) indoor
units.
Combinations SHOULD NOT:
Exceed the maximum allowable total
indoor unit connected capacity of
33,000 Btu.
MR36TQY3JMA:
FOR (2) ZONES:
Minimum combination must be 50% of
nameplate capacity
FOR (3) ZONES:
Select any combination of (3) indoor
units with no more than (2) 18,000 Btu
indoor units plus (1) other indoor unit.
FOR (4) ZONES:
Select any combination of (4) indoor
units.
Combinations SHOULD NOT:
Exceed the maximum allowable total
indoor unit connected capacity of
48,000 Btu.
MR48DEY3JM:
FOR (2) ZONES:
Minimum combination must be 50% of
nameplate capacity
FOR (3) ZONES:
Select any combination of (3*) indoor
units per system. *Combination must
be 50% of nameplate capacity.
FOR (4) THROUGH (8) ZONES:
With (3) 18,000 Btu indoor units only a
7,000 or 9,000 Btu indoor can be used.
Combinations SHOULD NOT:
1. Exceed the maximum allowable
total indoor unit connected capacity
of 65,000 Btu.
2. Be below the minimum connectible
capacity of 24,000 Btu.
8915239Mixed Ducted and Non-ducted Indoor Units4600011.65 18.50 52000 9.8534300
System
CapacityEERSEER
High
Heat
47�F HSPF
Low
Heat
17�F
29
Page 30
REFRIGERATION LINE SETS MINIMUM/MAXIMUM LENGTHS
SINGLE ZONE
Single Zone
System ModelOutdoorIndoorMin. (ft.)Max. (ft.)
HM09YJAHMR09Y3JAHMW09Y3JA1065
HM12YJAHMR12Y3JAHMW12Y3JA1065
M18YJMR18Y3JMW18Y3J1066
M09CJMR09C1JMW09C1J766
M12CJMR12C1JMW12C1J766
M18CJMR18C3JMW18C3J1066
M24CJMR24C3JMW24C3J1098
M24YJMR24Y3JMW24Y3J10164
M36YJMR36Y3JMW36Y3J10164
HM09YJ
HM12YJAMHR12Y3JAMHW12Y3JA1049
C24YJMR24UY3JMC24Y3J25164
C36YJMR36UY3JMC36Y3J25246
D24YJMR24UY3JMD24Y3J25164
D36YJMR36UY3JMD36Y3J25246
REFRIGERATION LINE SETS MINIMUM/MAXIMUM LENGTHS
MULTIZONE | 24,000 AND 36,000 BTUs
Multizone Outdoor
MR24DY3JMADual Zone10*82246
MR24DY3JMATri Zone10*82246
MR36TQY3JMA Dual Zone10*82246
MR36TQY3JMA Tri or Quad Zone10*82246
Individual Zone
Line Lengths
Min. (ft.)Max. (ft.)Max. (ft.)
Combined System
Line Lengths
TORQUE WRENCH SETTINGS
Outside DiameterTorque
mminchN.mkgf.mlbf.ft
Ø6.351/414~181.4~1.810~13
Ø9.523/834~423.5~4.325~31
Ø12.71/249~615.0~6.236~45
Ø15.885/869~827.0~8.451~60
Ø19.053/4100~12010.0~12.273~88
*The combined line lengths of the individual zones must equal the minimum line length for the selected multizone system.
For a Dual Zone System: The combined lengths must equal at least 25 feet.
For a Tri Zone or Quad Zone System: The combined lengths must equal at least 75 ft.
30 | FRIEDRICH J SERIES DUCTLESS
Page 31
REFRIGERATION LINE SETS MINIMUM/MAXIMUM LENGTHS
MULTIZONE | 48,000 BTU
Multizone 48,000 BTU/h Eight Zone
Total piping length (Outdoor to Indoor ) (Tp)(ft.)≤476
Min. (ft.)10
Max. (ft.)≤180
Min.(ft.)10
Max.(ft.)≤49
System Pipe
Lengths
Max. Elevations
Outdoor to Branch box (A, B)
Total branch piping length (Branch Box to indoor units) (A1-A3, B1-B4)(ft.)≤295
Branch box to Indoor units
If outdoor unit is above or below indoor unit (E1)(ft.)≤98
Between the farthest two indoor units (E3)(ft.)≤49
Between branch distribution unit and farthest connected indoor unit(s) (E2)(ft.)≤33
Between branch boxes (E4)(ft.)≤49
(Tp)
A
BB unit
A1
E4
E1
B
BB unit
B1
B4
SINGLE AND DUAL BB CONFIGURATIONS
BB unit
A2
E3
A3
E2
B2
B3
Required for MR48DEY3JM
Y-Branch (DYBK)
Branch Box D4PBB
BB unit
Y - Branch DYBK
Branch boxes have up to 4 outlets and
do not require separate power, they
are powered from the condenser.
31
Page 32
OPTIONAL WIRED WALL CONTROLLER
WIRED WALL CONTROLLER
DWC2- Works with all Friedrich J Series ductless models except HM09Y3JA and HM12Y3JA
PROGRAMMABLE SETTINGS
• Simple program (1 to 7 hour) ON/OFF
• Sleep program
• 7 Day schedule
• Holiday schedule
• ON/OFF at set time
WIRELESS DIAGNOSTIC TOOL FOR FRIEDRICH J SERIES* DUCTLESS SPLIT SYSTEMS
Monitor and diagnose J Series Ductless Systems for quick service responses
3 EASY STEPS:
1. Download the Friedrich
Diagnostic App from
Google Play or App Store
2. Connect DWTST module to
the outdoor unit
3. Begin monitoring unit
DWTST
IMPORTANT
Technician can observe
various data points, such as:
• Thermistor temps
• DC link voltage
• Fan RPM
• EEV pulse
• Error codes
• Trouble shooting guide
• Input voltage
• Amperage
*Friedrich DWTST works with Friedrich J Series Ductless Split Systems, except HM09Y3JA and HM12Y3JA.
Not for use with other Friedrich models or other brands. Applications are subject to change without notice.
NOMENCLATURE
1
1 Series 2Model Type3Capacity4Application5 Refrigeration
All Friedrich ductless split products require a licensed contractor for installation.
2
M
W=Wall-mounted
C=Cassette
D=The Insider (Concealed Ducted)
R=Outdoor Component
WH=Wall-mounted High SEER
RH=Outdoor High SEER
Mini-split
RM=Floating Air Outdoor
WM=Floating Air Indoor
Friedrich Air Conditioning Co. l 10001 Reunion Place, Suite 500 l San Antonio, TX 78216 l 877.599.5665 l www.friedrich.com