Friedrich 9359944065 User Manual

AIR CONDITIONER
FLOOR CONSOLE/ UNDER CEILING DUAL TYPE
MODE D’EMPLOI
MANUAL DE FUNCIONAMIENTO
English
Français
KEEP THIS MANUAL FOR FUTURE REFERENCE CONSERVEZ CE MODE D'EMPLOI AFIN DE POUVOIR VOUS Y RÉFÉRER ULTÉRIEUREMENT GUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTURO
Español
P/N9359944065
CONTENTS
SAFETY PRECAUTIONS ....................................... 1
FEATURES AND FUNCTIONS .............................. 2
NAME OF PARTS ................................................... 3
PREPARATION ....................................................... 5
OPERATION ........................................................... 6
TIMER OPERATION ............................................... 8
SLEEP TIMER OPERATION ................................... 9
MANUAL AUTO OPERATION ............................... 9
ADJUSTING THE DIRECTION OF
AIR CIRCULATION ............................................... 10
SWING OPERATION............................................ 11
CLEANING AND CARE ........................................ 12
SELECTING THE REMOTE CONTROL UNIT
SIGNAL CODE ..................................................... 13
TROUBLESHOOTING .......................................... 14
OPERATING TIPS ................................................ 15
SAFETY PRECAUTIONS
Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way.
The instructions in this section all relate to safety; be sure to maintain safe operating conditions.
“DANGER”, “WARNING” and “CAUTION” have the following meanings in these instructions:
DANGER!
WARNING!
CAUTION!
DANGER!
CAUTION!
This mark indicates procedures which, if improperly performed, are most likely to result in the death of or serious injury to the user or service personnel.
This mark indicates procedures which, if improperly performed, might lead to the death or serious injury of the user.
This mark indicates procedures which, if improperly performed, might possibly result in personal harm to the user, or damage to property.
Do not attempt to install this air conditioner by yourself.
This unit contains no user-serviceable parts. Always consult authorized service per-
sonnel for repairs.
When moving, consult authorized service personnel for disconnection and installation of the unit.
Do not become over-exposed to cold air by staying in the direct path of the airflow of the air conditioner for extended periods of time.
Do not insert fingers or objects into the outlet port or intake grilles.
Do not start and stop air conditioner operation by disconnecting the power supply
cord and so on.
Take care not to damage the power supply cord.
In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off
the electrical breaker, and
Provide occasional ventilation during use.
Do not direct air flow at fireplaces or heating apparatus.
Do not climb on, or place objects on, the air conditioner.
Do not hang objects from the indoor unit.
Do not set flower vases or water containers on top of air conditioners.
Do not expose the air conditioner directly to water.
Do not operate the air conditioner with wet hands.
Do not pull power supply cord.
Turn off power source when not using the unit for extended periods.
Check the condition of the installation stand for damage.
Do not place animals or plants in the direct path of the air flow.
Do not drink the water drained from the air conditioner.
Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.
Do not apply any heavy pressure to radiator fins.
Operate only with air filters installed.
Do not block or cover the intake grille and outlet port.
Ensure that any electronic equipment is at least one metre away from either the in-
door or outdoor units.
Avoid installing the air conditioner near a fireplace or other heating apparatus.
When installing the indoor and outdoor units, take precautions to prevent access by
infants.
Do not use inflammable gases near the air conditioner.
consult authorized service personnel.
En-1
FEATURES AND FUNCTIONS
AUTOMATIC OPERATION
COOLING MODEL
Merely press the START/STOP button, and the unit will begin automatic operation in the Cooling or Dry mode as appropriate, in accordance with the thermostat setting and the actual temperature of the room.
HEAT & COOL MODEL (REVERSE CYCLE)
Merely press the START/STOP button, and the unit will begin automatic operation in either the Heating, Cooling or Monitor modes as appropriate, in accordance with the thermostat setting and the actual temperature of the room.
SLEEP TIMER
COOLING MODEL
When the SLEEP timer button is pressed during Cooling or Dry mode, the thermostat setting is gradually rised during the period of operation. When the set time is reached, the unit automatically turns off.
HEAT & COOL MODEL (REVERSE CYCLE)
When the SLEEP timer button is pressed during Heating mode, the air conditioner’s thermostat setting is gradu­ally lowered during the period of operation; during Cool­ing or Dry mode, the thermostat setting is gradually rised during the period of operation. When the set time is reached, the unit automatically turns off.
WIRELESS REMOTE CONTROL UNIT
The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation.
OMNI-DIRECTIONAL AIR FLOW (SWING OPERATION)
Three-dimensional control over air direction swing is possi­ble through dual use of both an UP/DOWN air direction swing and RIGHT/LEFT air direction swing. Since UP/DOWN air direction flaps operate automatically according to the oper­ating mode of the unit, it is possible to set air direction based on the operating mode.
MILDEW-RESISTANT FILTER
The AIR FILTER has been treated to resist mildew growth, thus allowing cleaner use and easier care.
En-2
NAME OF PARTS
Instructions relating to heating (*) are applicable only to HEAT & COOL MODEL (Reverse Cycle).
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 6
Fig. 5
En-3
Fig. 1 Indoor Unit
1 Operating Control Panel (Fig. 2) 2 MANUAL AUTO button 3 Remote Control Signal Receiver 4 OPERATION Indicator Lamp (red) 5 TIMER Indicator Lamp (green) 6 SWING Indicator Lamp (orange)
(VERTICAL SWING)
7 SWING Indicator Lamp (orange)
(HORIZONTAL SWING)
If the TIMER indicator lamp flashes when
the timer is operating, it indicates that a fault has occurred with the timer setting
(See page 16 Auto Restart).
8 Intake Grille (Fig. 3) 9 Air Filter 0 UP/DOWN Air Direction Flaps A RIGHT/LEFT Air Direction Louvers
(behind UP/DOWN Air Direction Flaps)
B Drain Hose
Fig. 4 Remote Control Unit
C SLEEP button D MASTER CONTROL button E SET TEMP./SET TIME buttons ( F Signal Transmitter G TIMER button H FAN CONTROL button I START/STOP button J AIR FLOW DIRECTION
VERTICAL SET button
K AIR FLOW DIRECTION
VERTICAL SWING button
L AIR FLOW DIRECTION
HORIZONTAL SET button
M AIR FLOW DIRECTION
HORIZONTAL SWING button
N TIME ADJUST button O ACL button
Rear side (Fig. 5) P TEST RUN
Touch the two metal contacts with a me­tallic object to send the signal to perform a test run.
Perform a test run only when installing the air conditioner. If the signal to perform a test run is received during normal opera­tion, the air conditioners thermostat will malfunction.
If the signal to perform a test run is re­ceived during normal operation, the unit will switch to the test operation mode and the indoor units OPERATION and TIMER indicator lamps will flash simultaneously.
To stop the test operation mode, press the START/STOP button to stop the air condi­tioner.
Q Remote Control Unit Display (Fig. 6) R Transmit Indicator S Clock Display T Operating Mode Display U T imer Mode Display V Fan Speed Display W Temperature Set Display X T imer Set Indicator Y Temperature Set Indicator
)
En-4
PREPARATION
Load Batteries (R03/LR03/AAA × 2)
Press and slide the battery compartment lid on the re-
1
verse side to open it.
Slide in the direction of the arrow while pressing the mark.
Insert batteries.
2
Be sure to align the battery polarities ( ) correctly.
Close the battery compartment lid.
3
Set the Current time
Press the TIME ADJUST button.
1
Use the tip of a ball-point pen or other small object to press the button.
Use the ( ) SET TIME buttons to adjust the clock
2
to the current time.
button: Press to advance the time. button: Press to reverse the time.
(Each time the buttons are pressed, the time will be advanced/reversed in one-minute increments; hold the buttons depressed to change the time quickly in ten-minute increments.)
CAUTION!
Take care to prevent infants from accidentally swallowing batteries.
When not using the remote control unit for an extended period, remove the batteries to avoid possible leakage and damage to the unit.
If leaking battery fluid comes in contact with your skin, eyes, or mouth, immedi­ately wash with copious amounts of water, and consult your physician.
Dead batteries should be removed quickly and disposed of properly, either by placing in a public battery collection receptacle, or by returning to appropri­ate authority.
Do not attempt to recharge dry batteries.
Never mix new and used batteries, or batteries of different types. Batteries should last about one year under normal use. If the remote control units operating range becomes appre­ciably reduced, replace the batteries and press the ACL button with the tip of a ballpoint pen or other small object.
Press the TIME ADJUST button again.
3
This completes the time setting and starts the clock.
To Use the Remote Control Unit
The remote control unit must be pointed at signal receiver to operate correctly.
Operating range: About 7 meters.
When a signal is properly received by the air conditioner, a beeping sound will
be heard.
If no beep is heard, press the remote control unit button again.
Remote Control Unit Holder
Insert
Press in
Screws
1 Mount the Holder. 2 Set the Remote Control Unit.
Slide up
Pull out
3 To remove the Remote
Control Unit (when use at hand).
En-5
OPERATION
Instructions relating to heating (*) are applicable only to HEAT & COOL MODEL (Reverse Cycle).
To Select Mode Operation
Press the START/STOP button.
1
The indoor unit’s OPERATION indicator lamp (red) will light. The air conditioner will start operating.
Press the MASTER CONTROL button to select the de-
2
sired mode.
Each time the button is pressed, the mode will change in the following order:
s
AUTO COOL DRY
About three seconds later, the entire display will reappear.
*HEAT FAN
To Set the Thermostat
Press the SET TEMP. buttons.
button: Press to rise the thermostat setting. button: Press to lower the thermostat setting.
Thermostat setting range:
AUTO .................................. 64 to 88 °F
* Heating ............................... 60 to 88 °F
The thermostat cannot be used to set room temperature during the FAN mode (the temperature will not appear on the remote control units display).
Cooling/Dry ........................ 64 to 88 °F
s
t
s
t
Example: When set to COOL
About three seconds later, the entire display will reappear.
The thermostat setting should be considered a standard value, and may differ somewhat from the actual room temperature.
To Set the Fan Speed
Press the FAN CONTROL button.
Each time the button is pressed, the fan speed changes in the following order:
AUTO HIGH MED LOW
About three seconds later, the entire display will reappear.
When set to AUTO: * Heating : Fan operates so as to optimally circulate warmed air.
However, the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low.
Cooling : As the room temperature approaches that of the thermostat setting,
the fan speed becomes slower.
Fan : The fan alternately turns on and off; when on, the fan runs at the low
fan speed.
The fan will operate at a very low setting during Monitor operation and at the start of the Heating mode.
s
sss
To Stop Operation
Example: When set to 88 °F
Example: When set to AUTO
Press the START/STOP button.
The OPERATION indicator lamp (red) will go out.
En-6
OPERATION
Instructions relating to heating (*) are applicable only to HEAT & COOL MODEL (Reverse Cycle).
About Mode Operation
AUTO: COOLING MODEL
When the room temperature is 4 °F higher than the set temperature, the mode will switch between Cooling and Drying.
During the Drying mode operation, the FAN setting should be switched to LOW for a gently cooling effect during which the fan may temporarily stop rotating.
If the mode automatically selected by the unit is not satisfactory, see page 6 for in­structions on changing the mode setting (COOL, DRY, FAN).
AUTO (* AUTO CHANGEOVER): HEAT & COOL MODEL (Reverse Cycle)
When AUTO CHANGEOVER is selected, the air conditioner selects the appropri­ate operation mode (Cooling or Heating) according to your rooms present tem­perature.
When AUTO CHANGEOVER is first selected, the fan will operate at very low speed for about one minute while the unit determines the current conditions of the room and accordingly selects the proper operation mode.
When the air conditioner has adjusted your room’s temperature to near the ther- mostat setting, it will begin monitor operation. In the monitor operation mode, the fan will operate at low speed. If the room temperature subsequently changes, the air conditioner will once again select the appropriate operation (Heating, Cool­ing) to adjust the temperature to the value set in the thermostat. (The monitor operation range is ± 4 °F relative to the thermostat setting.)
If the mode automatically selected by the unit is not satisfactory, see page 6 for instructions on changing the mode setting (HEAT, COOL, DRY, FAN).
Cooling Operation
Dry Operation
Thermostat control
4 °F
Setting temperature
*Heating:
Use to warm your room.
When Heating mode is selected, the air conditioner will operate at very low fan
speed for about 3 to 5 minutes, after which it will switch to the selected fan set­ting. This period of time is provided to allow the indoor unit to warm up before beginning full operation.
When the room temperature is very low, frost may form on the outside unit, and its performance may be reduced. In order to remove such frost, the unit will automatically enter the defrost cycle from time to time. During Automatic De­frosting operation, the OPERATION indicator lamp (red) will flash, and the heat operation will be interrupted.
Cooling:
Use to cool your room.
Dry:
Use for gently cooling while dehumidifying your room.
You cannot heat the room during Dry mode.
During Dry mode, the unit will operate at low speed; in order to adjust room
humidity, the indoor unit’s fan may stop from time to time. Also, the fan may operate at very low speed when detecting room humidity.
The fan speed cannot be changed manually when Dry mode has been selected.
Fan:
Use to circulate the air throughout your room.
* During Heating mode:
Set the thermostat to a temperature set­ting that is higher than the current room temperature. The Heating mode will not operate if the thermostat is set lower than the actual room temperature.
During Cooling/Dry mode:
Set the thermostat to a temperature set­ting that is lower than the current room temperature. The Cooling and Dry modes will not operate if the thermostat is set higher than the actual room temperature (in Cooling mode, the fan alone will oper­ate).
During Fan mode:
The heat and cool functions of this unit cannot operate at the same time.
En-7
TIMER OPERATION
Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (See page 5).
To Use the ON timer or OFF timer
Press the START/STOP button
1
(if the unit is already operating, proceed to step 2).
The indoor unit’s OPERATION indicator lamp (red) will light.
Press the TIMER button to select the OFF timer or ON
2
timer operation.
Each time the button is pressed the timer function changes in the follow­ing order:
RESET OFF ON
PROGRAM (OFF ON, OFF ON)
The indoor units TIMER indicator lamp (green) will light.
sss
t
Use the SET TIME buttons to adjust the desired OFF
3
time or ON time.
Set the time while the time display is flashing (the flashing will continue for about five seconds).
button: Press to advance the time. button: Press to reverse the time.
About five seconds later, the entire display will reappear.
To Cancel the Timer
Use the TIMER button to select “TIMER RESET. The air conditioner will return to normal operation.
To Change the Timer Settings
Perform steps 2 and 3.
To Stop Air Conditioner Operation while the Timer is Operating
Press the START/STOP button.
To Change Operating Conditions
If you wish to change the operating conditions (Mode, Fan Speed, Thermostat Setting), after making the timer setting, wait until the entire display reappears, then press the appropriate buttons to change the operating condition desired.
To Use the PROGRAM timer
Press the START/STOP button
1
(if the unit is already operating, proceed to step 2).
The indoor units OPERATION indicator lamp (red) will light.
Set the desired times for OFF timer and ON timer.
2
See the section To Use the ON timer or OFF timer to set the desired mode and times. About three seconds later, the entire display will reappear. The indoor units TIMER indicator lamp (green) will light.
Press the TIMER button to select the PROGRAM timer
3
operation (either OFF ON or OFF ON will display).
The display will alternately show OFF timer and ON timer, then change to show the time setting for the operation to occur first.
The PROGRAM timer will begin operation. (If the ON timer has been selected to operate first, the unit will stop operating at this point.)
About five seconds later, the entire display will reappear.
About the PROGRAM timer
The PROGRAM timer allows you to integrate OFF timer and ON timer operations in a single sequence. The se­quence can involve one transition from OFF timer to ON timer, or from ON timer to OFF timer, within a twenty­four hour period.
The first timer function to operate will be the one set near­est to the current time. The order of operation is indicated by the arrow in the remote control unit’s display (OFF ON, or OFF ON).
One example of PROGRAM timer use might be to have the air conditioner automatically stop (OFF timer) after you go to sleep, then start (ON timer) automatically in the morning before you rise.
To Cancel the Timer
Use the TIMER button to select “TIMER RESET. The air conditioner will return to normal operation.
To Change the Timer Settings
1.
Follow the instructions given in the section To Use the ON Timer or OFF Timer to se­lect the timer setting you wish to change.
2. Press the TIMER button to select either OFF ON or OFF ON.
To Stop Air Conditioner Operation while the Timer is Operating
Press the START/STOP button.
To Change Operating Conditions
If you wish to change operating conditions (Mode, Fan Speed, Thermostat Setting), after making the timer setting, wait until the entire display reappears, then press the appropriate buttons to change the operat­ing condition desired.
About the ON timer
The timer function is designed to bring your room to a comfortable temperature by the set time; as a result, the unit automatically begins operation before the set time so that the room reaches the desired temperature by the time set on the timer.
The hotter it is in summer, or the colder it is in winter, the earlier that operation will begin.
* During Heating Operation .......from 45 to 10 minutes be-
During Cooling/Dry Operation ... from 20 to 10 minutes be-
During Fan Operation .............. at the set time.
fore set time.
fore set time.
En-8
SLEEP TIMER OPERATION
Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped.
To Use the SLEEP timer
While the air conditioner is operating or stopped, press the SLEEP button.
Both the indoor units OPERATION indicator lamp (red) and the TIMER indicator lamp (green) will light.
To Change the Timer Settings
Press the SLEEP button once again and set the time using the SET TIME buttons.
Set the time while the Timer Mode Display is flashing (the flashing will continue for about five seconds).
button: Press to advance the time. button: Press to reverse the time.
About five seconds later, the entire display will reappear.
About the SLEEP timer
To prevent excessive warming or cooling during sleep, the SLEEP timer function automatically modifies the thermostat setting in accordance with the time setting. When the set time has elapsed, the air conditioner completely stops.
During Heating operation (HEAT & COOL MODEL (Reverse cycle) only):
When the SLEEP timer is set, the thermostat setting is automatically lowered 2 °F every thirty minutes. When the thermostat has been lowered a total of 8 °F, the thermostat setting at that time is maintained until the set time has elapsed, at which time the air conditioner automatically turns off.
SLEEP timer setting
2 °F
4 °F
6 °F
30 minutes
8 °F
During Cooling/Dry operation:
When the SLEEP timer is set, the thermostat setting is auto­matically rised 2 °F every sixty minutes. When the thermostat has been rised a total of 4 °F, the thermostat setting at that time is maintained until the set time has elapsed, at which time the air conditioner automatically turns off.
SLEEP timer setting
To Cancel the Timer:
Use the TIMER button to select “TIMER RESET. The air conditioner will return to normal operation.
To Stop the Air Conditioner During Timer Operation:
Press the START/STOP button.
Set time
1 hour
1 hour
1 hour 30 minutes
Set time
2 °F
MANUAL AUTO OPERATION
Use the MANUAL AUTO operation in the event the remote control unit is lost or otherwise unavailable.
How To Use the Main Unit Controls
Press the MANUAL AUTO button on the main unit control panel.
To stop operation, press the MANUAL AUTO button once again.
En-9
CAUTION!
Do not press the MANUAL AUTO button with wet hands or pointed objects, otherwise an electric shock or malfunction may occur.
When the air conditioner is operated with the controls on the Main unit, it will operate under the same mode as the AUTO mode selected on the re­mote control unit (see page 7).
The fan speed selected will be “AUTO and the thermostat setting will be 74 °F.
4 °F
ADJUSTING THE DIRECTION OF AIR CIRCULATION
Instructions relating to heating (*) are applicable only to HEAT & COOL MODEL (Reverse Cycle).
Vertical (up-down) direction of airflow is adjusted by pressing the remote control unit’s AIR FLOW DIRECTION VERTICAL SET button. Horizontal (right-left) direction of airflow is adjusted by pressing the remote control unit’s AIR FLOW DIRECTION HORIZONTAL SET button.
Vertical Air Direction Adjustment
Press the AIR FLOW DIRECTION VERTICAL SET button.
Each time the button is pressed, the air direction range will change as follows:
2 3 4 5 6 7
1
Types of Air flow Direction Setting:
1,2,3,4 : During Cooling/Dry Modes 5,6,7 : * During Heating mode
The remote control units display does not change.
Fig. 7
Use the air direction adjustments within the ranges shown above.
The vertical airflow direction is set automatically as shown, in accordance with
the type of operation selected.
During Cooling/Dry mode : Horizontal flow 1
* During Heating mode : Downward flow 7
During AUTO mode operation, for the first minute after beginning operation,
airflow will be horizontal 1; the air direction cannot be adjusted during this pe­riod.
Horizontal Air Direction Adjustment
DANGER!
Never place fingers or foreign objects inside the outlet ports, since the internal fan oper­ates at high speed and could cause personal injury.
Always use the remote control unit’s AIR FLOW DIRECTION button to adjust the UP/DOWN air direction flaps or RIGHT/LEFT air direction louvers. At­tempting to move them manually could result in improper operation; in this case, stop operation and restart. The louvers should begin to operate properly again.
During use of the Cooling and Dry modes, do not set the UP/DOWN air direction flaps in the Heating range (5 to 7) for long periods of time, since water vapor may condense near the outlet louvers and drops of water may drip from the air conditioner.
When used in a room with infants, chil­dren, elderly or sick persons, the air direction and room temperature should be considered carefully when making settings.
Press the AIR FLOW DIRECTION HORIZONTAL SET button.
Each time the button is pressed, the air direction range will change as follows:
2 3 4 5
1
The remote control units display does not change.
Use the air direction adjustments within the ranges shown above.
Fig. 8
RIGHT/LEFT air direction louvers
Example: When set to vertical air direc-
tion
Example: When set to horizontal air di-
rection
En-10
SWING OPERATION
Begin air conditioner operation before performing this procedure.
To select Vertical airflow SWING Operation
Press the AIR FLOW DIRECTION VERTICAL SWING button.
The SWING indicator lamp (VERTICAL SWING) (orange) will light. In this mode, the UP/DOWN air direction flaps will swing automatically to direct the air flow both up and down.
To Stop Vertical airflow SWING Operation
Press the AIR FLOW DIRECTION VERTICAL SWING button once again.
The SWING indicator lamp (VERTICAL SWING) will go out. Airflow direction will return to the setting before swing was begun.
About Swing Operation
Example: When set to vertical swing
The range of swing is relative to the currently set airflow direction.
Air flow direction set
1 2 3 4 5 6 7
Air direction range (See page 10, Fig. 7)
Range of swing
1 to 3 1 to 4 2 to 5 3 to 6 4 to 7 5 to 7
1 to 7 (All range)
If the swing range is not as desired, use the remote con­trol unit’s AIR FLOW DIRECTION VERTICAL SET button to change the range of swing.
The SWING operation may stop temporarily when the air conditioners fan is not operating, or when operating at very low speeds.
During use of the Cooling and Dry modes, do not set the air UP/DOWN direction flaps, in the Heating range (5 to
7) for long periods of time, since water vapor may con­dense near the outlet louvers and drops of water may drip from the air conditioner.
To select Horizontal airflow SWING Operation
Press the AIR FLOW DIRECTION HORIZONTAL SWING button.
The SWING indicator lamp (HORIZONTAL SWING) (orange) will light. In this mode, the RIGHT/LEFT air direction louvers will swing automatically to direct the airflow both right and left.
To Stop Horizontal airflow SWING Operation
Press the AIR FLOW DIRECTION HORIZONTAL SWING button once again.
The SWING indicator lamp (HORIZONTAL SWING) will go out. Airflow direction will return to the setting before swing was begun.
Example: When set to horizontal swing
About Swing Operation
The range of swing is relative to the currently set airflow direction.
Air flow direction set
1 2 3 4 5
Air direction range (See page 10, Fig. 8)
Range of swing
1 to 5 (All range)
1 to 3 2 to 4 3 to 5
1 to 5 (All range)
En-11
If the swing range is not as desired, use the remote con­trol unit’s AIR FLOW DIRECTION HORIZONTAL SET but- ton to change the range of swing.
The SWING operation may stop temporarily when the air conditioners fan is not operating, or when operating at very low speeds.
CLEANING AND CARE
Before cleaning the air conditioner, be sure to turn it off and disconnect the power supply cord.
CAUTION!
Cleaning the Air Filter
Be sure the intake grille is installed securely.
When removing and replacing the air filters, be sure not to touch the heat exchanger, as per-
sonal injury may result.
1. Pull out both sides and the center of the intake grille.
About 30 mm
(1-3/16”)
Arm
Intake Grille
Side Panel
Hook
Notch
Arm
2. Pull the air filters upward to remove them.
Push the air filter handles away from the intake grille in direction 1, then pull out the air filters.
1
Air Filter
4. Re-attach the air filters to the intake grille.
1 The air filters fit onto the inside of the intake grille.
(figure 1)
2 The bottom edges of the air filters should fit into the
filter brackets. (figure 1)
3 The air filters should be pushed down so that their
top edges fit under the projections at the top of the intake grille. (figure 2)
Air Filter
(Figure 1)
Filter bracket
(Figure 2)
5. Push in both sides and the center of the intake grille.
Bracket
Handle
Intake Grille
3. Clean the air filters.
Remove the dust from the air filters by vacuuming or washing them. After washing, allow the air filters to dry thoroughly in an area protected from sunlight.
When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service personnel.
When cleaning the unit’s body, do not use water hotter than 104 °F, harsh abrasive cleansers, or volatile agents like benzene or thinner.
Do not expose the unit body to liquid insecticides or hairsprays.
If the unit will not be operated for a period of one month or more, be sure to allow the inner parts of the unit to dry
thoroughly, in advance, by operating the unit in fan mode for half a day.
Base
Dust can be cleaned from the air filter either with a vacuum cleaner, or by washing the filter in a solution of mild de­tergent and warm water. If you wash the filter, be sure to allow it to dry thoroughly in a shady place before rein­stalling.
If dirt is allowed to accumulate on the air filter, air flow will be reduced, lowering operating efficiency and increas­ing noise.
During periods of normal use, the air filters should be cleaned every two weeks.
En-12
SELECTING THE REMOTE CONTROL UNIT SIGNAL CODE
When two or more air conditioners are installed in a room and the remote control unit is operating an air conditioner other than the one you wish to set, change the signal code of the remote control unit to operate only the air conditioner you wish to set (four selections possible). When two or more air conditioners are installed in a room, please contact your retailer to set the individual air conditioner signal codes.
Selecting the Remote Control Unit Signal Code
Use the following steps to select the signal code of the remote control unit. (Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code.)
Press the START/STOP button until only the clock is
1
displayed on the remote control unit display.
Press the MASTER CONTROL button for at least five
2
seconds to display the current signal code (initially set to ).
To operate only one of multiple air conditioners
Press the buttons to change the signal code be-
3
tween air conditioner signal code.
Press the MASTER CONTROL button again to return to
4
the clock display. The signal code will be changed.
If no buttons are pressed within 30 seconds after the signal code is displayed, the system returns to the original clock display. In this case, start again from step 1.
The air conditioner signal code is set to A prior to shipment. Contact your retailer to change the signal code.
The remote control unit resets to signal code A when the batteries in the remote control unit are replaced. If you use a signal code other than signal code A, reset the signal code after replacing the batteries. If you do not know the air conditioner signal code setting, try each of the signal codes ( code which operates the air conditioner.
. Match the code on the display to the
) until you find the
En-13
TROUBLESHOOTING
Instructions relating to heating (*) are applicable only to HEAT & COOL MODEL (Reverse Cycle).
WARNING!
Before requesting service, perform the following checks:
In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the power supply plug, and consult authorized service personnel. Merely turning off the units power switch will not completely disconnect the unit from the power source. Always be sure to disconnect the power supply plug or turn off your circuit breaker to ensure that power is completely off.
NORMAL
FUNCTION
Symptom
Doesnt operate immedi­ately:
Noise is heard:
Smells:
Mist or steam are emitted:
Problem
If the unit is stopped and then immediately started again, the com­pressor will not operate for about 3 minutes, in order to prevent fuse blowouts.
Whenever the power supply plug is disconnected and then recon­nected to a power outlet, the protection circuit will operate for about 3 minutes, preventing unit operation during that period.
During operation and immediately after stopping the unit, the sound of water flowing in the air conditioners piping may be heard. Also, noise may be particularly noticeable for about 2 to 3 minutes after starting operation (sound of coolant flowing).
During operation, a slight squeaking sound may be heard. This is the result of minute expansion and contraction of the front cover due to temperature changes.
*During Heating operation, a sizzling sound may be heard occa-
sionally. This sound is produced by the Automatic Defrosting op­eration.
Some smell may be emitted from the indoor unit. This smell is the result of room smells (furniture, tobacco, etc.) which have been taken into the air conditioner.
During Cooling or Dry operation, a thin mist may be seen emitted from the indoor unit. This results from the sudden Cooling of room air by the air emitted from the air conditioner, resulting in con­densation and misting.
See Page
15
Airflow is weak or stops:
Water is produced from the outdoor unit:
*During Heating operation, the outdoor unit’s fan may stop, and
steam may be seen rising from the unit. This is due to the Auto­matic Defrosting operation.
*When Heating operation is started, fan speed is temporarily very
low, to allow internal parts to warm up.
*During Heating operation, if the room temperature rises above
the thermostat setting, the outdoor unit will stop, and the indoor unit will operate at very low fan speed. If you wish to warm the room further, set the thermostat to a higher setting.
*During Heating operation, the unit will temporarily stop opera-
tion (between 7 and 15 minutes) as the Automatic Defrosting mode operates. During the Automatic Defrosting operation, the OPERA­TION indicator lamp will flash.
The fan may operate at very low speed during Dry operation or when the unit is monitoring the rooms temperature.
In the monitor AUTO operation, the fan will operate at very low speed.
*During Heating operation, water may be produced from the out-
door unit due to the Automatic Defrosting operation.
15
15
6
6
15
En-14
TROUBLESHOOTING
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
Symptom
CHECK ONCE
MORE
If the problem persists after performing these checks, or if you notice burning smells, or the TIMER indicator lamp flashes, stop operation immediately, disconnect the power supply plug, and consult with authorized service personnel.
Doesnt operate at all:
Poor Cooling (or *Heating) performance:
The unit operates differ­ently from the remote con­trol unit’s setting:
Signal is not received after replacing the batteries for the remote control unit:
Has there been a power failure?
Has a fuse blown out, or a circuit breaker been tripped?
Is the timer operating?
Is the air filter dirty?
Are the air conditioners intake grille or outlet port blocked?
Did you adjust the room temperature settings (thermostat) cor-
rectly?
Is there a window or door open?
In the case of Cooling operation, is a window allowing bright sun-
light to enter? (Close the curtains.)
In the case of Cooling operation, are there heating apparatus and computers inside the room, or are there too many people in the room?
Are the remote control units batteries dead?
Are the remote control units batteries loaded properly?
Are you using an air conditioner signal code other than signal
code A?
Items to check
See Page
8 to 9
5
13
OPERATING TIPS
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
Operation and Performance
*Heating Performance
This air conditioner operates on the heat-pump principle, absorbing heat from outdoor air and transferring that heat indoors. As a result, the operating performance is reduced as outdoor air temperature drops. If you feel that insuffi­cient heating performance is being produced, we recom­mend you use this air conditioner in conjunction with another kind of heating appliance.
Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air con­ditioner until the room is heated.
*
When Indoor and Outdoor Temperature are High
When both indoor and outdoor temperatures are high during use of the heating mode, the outdoor units fan may stop at times.
*Microcomputer-controlled Automatic Defrosting
When using the Heating mode under conditions of low outdoor temperature and high humidity, frost may form on the outdoor unit, resulting in reduced operating per­formance.
In order to prevent this kind of reduced performance, this unit is equipped with a Microcomputer-controlled Auto­matic Defrosting function. If frost forms, the air condi­tioner will temporarily stop, and the defrosting circuit will operate briefly (for about 7 to 15 minutes).
During Automatic Defrosting operation, the OPERATION indicator lamp (red) will flash.
*Low Ambient Cooling
When the outdoor temperature drops, the outdoor unit’s fans may switch to Low Speed.
En-15
OPERATING TIPS
AUTO Restart
In Event of Power Interruption
Should the power supply to the air conditioner be inter­rupted by a power failure, the air conditioner will restart automatically in the previously selected mode once the power is restored.
Should a power failure occur during TIMER operation, the timer will be reset and the unit will begin (or stop) oper­ating under the new timer setting. In this event, the TIMER indicator lamp (green) will flash (see page. 4).
Multi-type Air conditioner
This indoor unit can be connected to a multi-type outdoor unit. The multi-type air conditioner allows multiple indoor units to be operated in multiple locations. The indoor units may be operated simultaneously, in accordance with their respective output.
Simultaneous Use of Multiple Units
Instructions relating to inverter (
When using a multi-type air conditioner, the multiple indoor units can be operated simultaneously, but when two or more indoor units of the same group are oper­ated simultaneously, the heating and cooling efficiency will be less than when a single indoor unit is used alone. Accordingly, when you wish to use more than one in­door unit for cooling at the same time, the use should be concentrated at night and other times when less out­put is required. In the same way, when multiple units are used simultaneously for heating, it is recommended that they be used in conjunction with other auxiliary space heaters, as required.
Seasonal and outdoor temperature conditions, the struc­ture of the rooms and the number of persons present may also result in differences of operating efficiency. We recommend that you try various operating patterns in order to confirm the level of heating and cooling out­put provided by your units, and use the units in the way that best matches your family's lifestyle.
If you discover that one or more units delivers a low level of cooling or heating during simultaneous opera­tion, we recommend that you stop simultaneous opera­tion of the multiple units.
Operation cannot be done in the following different op-
erating modes.
If the indoor unit is instructed to do an operating mode that it cannot perform, the OPERATION indicator lamp (red) on the indoor unit will flash (1 second on, 1 sec­ond off) and the unit will go into the standby mode.
Heating mode and cooling mode (or dry mode)
Heating mode and fan mode
) are applicable only to INVERTER MODEL”.
Use of other electrical appliances (electric shaver, etc.) or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction. In this event, temporarily disconnect the power supply plug, reconnect it, and then use the remote control unit to resume operation.
Operation can be done in the following different operat-
ing modes.
Cooling mode and dry mode
Cooling mode and fan mode
Dry mode and fan mode
The operating mode (heating mode or cooling (dry)
mode) of the outdoor unit will be determined by the op­erating mode of the indoor unit that was operated first. If the indoor unit was started in fan mode, the operating mode of the outdoor unit will not be determined.
For example, if indoor unit (A) was started in fan mode and then indoor unit (B) was then operated in heating mode, indoor unit (A) would temporarily start opera­tion in fan mode but when indoor unit (B) started oper­ating in heating mode, the OPERATION indicator lamp (red) for indoor unit (A) would begin to flash (1 second on, 1 second off) and it would go into standby mode. Indoor unit (B) would continue to operate in heating mode.
En-16
Loading...