Frico AR3500, AR4200 User Manual

AR3500/4200
AR3500/4200
Recessed air curtain for commercial premises, with intelligent control
Recommended installation height * AR3500: 3,5 m AR4200: 4,2 m
With its concealed placement, AR3500/4200 is very unobtrusive and with that particularly suitable for environments where the design is important.
Optimized airflow with
R
Thermozone technology.
Air velocity profile
AR3500 AR4200
m
0,1
1,0
2,0
3,0
10,7 m/s
6,0 m/s
4,4 m/s
3,5 m/s
• Low sound level.
• Mounting with threaded bars. The threaded bars can also be fixed on the inside of the unit e.g. when mounted on a solid suspended ceiling.
• Corrosion proof housing made of hot zinc-plate and powder enamelled steel panels. Colour frame and hatch: white, RAL 9016, NCS S 0500-N. Colour grille: grey, RAL 7046. The frame and hatch can be painted in an optional colour.
0,1
1,0
2,0
3,0
4,0
11,3 m/s
6,1 m/s
4,6 m/s
3,8 m/s
3,3 m/s
3,5
Measurements according to ISO 27327-1. Average values for products in the series.
3,3 m/s
Measurements according to ISO 27327-1. Average values for products in the series.
Control
This air curtain is supplied prepared for the SIRe control system that has many smart and energy saving functions. There are three different levels with different functionality to choose from, Basic, Competent or Advanced. Water heated units must always be supplemented with valves.
SIRe Basic SIRe Competent SIRe Advanced
*) Recommended installation height varies depending on the relevant premises.
For further information and options, see the "Controls" section.
4,2
3,2 m/s
2020-09-09
AR3500/4200
Recommended installation height 3,5 m
1 Ambient, no heat - AR3500 A (IP20)
Type Output
[kW]
AR3510A 0 1100/2300 78 42/62 230V~/2,45 A 1057 38
AR3515A 0 1550/3400 79 43/63 230V~/3,5 A 1567 51
AR3520A 0 2200/4800 80 45/64 230V~/5,2 A 2073 70
Airflow*
3
/h]
[m
1
Sound power* [dB(A)]
Sound
2
pressure* [dB(A)]
3
Voltage Amperage (control)
Length
[mm]
Weight
[kg]
3 Electrical heat - AR3500 E (IP20)
Type Output
steps [kW]
Airflow*
3
/h]
[m
1
AR3510E09 4,5/9 1100/2300 25/12 77 42/62 230V~/2,45 A 400 V3~/13 A 1057 42
AR3515E14 7/13,5 1550/3400 27/13 78 43/63 230V~/3,5 A 400 V3~/19,5 A 1567 61
AR3520E18 9/18 2200/4800 25/11 79 45/64 230V~/5,2 A 400 V3~/26 A 2073 79
t*
[°C]
4
Sound power* [dB(A)]
2
Sound pressure* [dB(A)]
Voltage
3
Amperage (control)
Voltage Amperage (heat)
Length
[mm]
2 Water heat - AR3500 W (IP20)
Type Output*5
[kW]
Airflow*
3
/h]
[m
1
AR3510W 9,4 1100/2300 16/12 1,3 77 42/61 230V~ 2,6 1057 42
AR3515W 14 1550/3400 16/12 2,1 78 42/62 230V~ 3,6 1567 58
AR3520W 21 2200/4800 16/13 2,9 79 44/63 230V~ 5,3 2073 76
2
Water heat - AR3500 WLL, coil for very low temperature water (460 °C) (IP20)
Type Output*6
[kW]
Airflow*
3
/h]
[m
1
AR3510WLL 9,2 1100/2300 14/12 1,3 76 42/61 230V~ 2,6 1057 45
AR3515WLL 14 1550/3400 15/12 2,1 77 42/62 230V~ 3,6 1567 61
AR3520WLL 20 2200/480 0 15/12 2,9 78 44/63 230V~ 5,3 2073 83
4,5
t*
[°C]
t*
[°C]
Water volume [l]
4,6
Water volume [l]
Sound power* [dB(A)]
Sound power* [dB(A)]
2
2
Sound pressure* [dB(A)]
Sound pressure* [dB(A)]
3
3
Voltage
[V]
Voltage
[V]
Amperage
[A]
Amperage
[A]
Length
[mm]
Length
[mm]
Weight
[kg]
Weight
[kg]
Weight
[kg]
Commercial
*1) Lowest/highest airflow of totally 5 fan steps.
2
) Sound power (LWA) measurements according to ISO 27327-2: 2014, Installation type E.
*
3
) Sound pressure (LpA). Conditions: Distance to the unit 5 metres. Directional factor: 2. Equivalent absorption area: 200 m². At lowest/
* highest airflow.
4
*
) t = temperature rise of passing air at maximum heat output and lowest/highest airflow.
5
) Applicable at water temperature 60/40 °C, air temperature, in +18 °C.
*
6
) Applicable at water temperature 40/30 °C, air temperature, in +18 °C.
*
Approved by SEMKO. Approved for 220V/1ph/60Hz and 380V/3ph/60Hz. Product performance for 220V/1ph/60Hz and 380V/3ph/60Hz will differ from stated data.