Franke Foodservice REF01 18001643 Parts List

TECHNICIAN’S QUICK REFERENCE GUIDE -
REF01 SLIDE-IN REFRIGERATOR
DOCUMENT PART NUMBER 19010030 REV A, 01-25-17
PART #’S:
18001643
(For other units, verify compatibility of parts with Technical Support before ordering)
SERVICE PARTS
1 19000881 Condensing Unit, 0.2 HP, MT, R-404A 1
2 19001079 Compressor Kit, TF3CLX, 115V/60Hz 1
3 19001083 Relay, Start, for TF3CLX 115V/60Hz 1
4 19001955 Capacitor, Start, Danfoss #117U5025 1
5 3126151 Switch, Carling LTA201TRB/125N 1
6 3589854 Fan Motor, Condenser, 9W 1
7 19001806 Blade, Condensing Fan 1
8 19000454 Fan Motor, Evaporator, with 5.5” Blade 1
9 19001189 Valve, Thermostatic Expansion, #0 1
10 3216122 Cap Tube 0.036” Dia. x 10’ (134a Models Only) 1
11 3587645 Door Gasket, 24” x 15-3/4” 2
12 3586246 Thermometer, Solar, 2” Dia. RR400 1
13 19000023 T-Stat, Danfoss 077B1262 1
14 19000801 Cordset, 10’ with Plug, 15A/120V/60Hz/1PH 1
15 18001476 Hinge Assembly, Upper 1
16 18001477 Hinge Assembly, Lower 1
17 3586183 Bushing Hinge 2
NOTICE!
SERVICE PERFORMED BY NON-AUTHORIZED SERVICE PROVIDERS OR USE OF NON-OEM PARTS MAY VOID EQUIPMENT WARRANTY.
Franke Foodservice Solutions, Inc. 800 Aviation Parkway Smyrna, TN 37167, USA Tel + 1.800.5.FRANKE, opt. 2
(1.800.537.2653, opt. 2)
www.frankeamericas.com
CONTROL SETTINGS & OPERATING CHARACTERISTICS
(For Trouble Shooting Reference) REF01 Slide-In Refrigerator
Temperature Controller Options For More Information
Temperature Range Adjustable
Coldest Set Point (Midpoint) 27°F
Normal Cut Out 34°F
Normal Cut In 40°F
Warmest Set Point (Midpoint) 40°F
Compressor Protection N/A
Minimum Time From Start to Start N/A
Fail Safe Mode (if sensor fails) N/A
Faulty Probe On Time
Faulty Probe Off Time
Defrost Settings N/A
Termination Temp
Maximum Time Allowed
Drip Time (heat off)
Defrost Based On Compressor On Time N/A
Time Between Defrosts
Fan Settings
During Defrost
Start Delay After Defrost
Start Delay
Display Features N/A
Can select degrees F or C?
Can adjust temperature from display?
Can Initiate Defrost from display?
Display During Defrost Cycle:
Refrigerant Type Amount, Ounces
R-404A REF-01 Mod. 1 16 oz
Normal Operating Pressures Normal Operating Amps
High Side (85 air to condenser) 235 PSIG REF-01 Mod. 1 3 - 4 Amps
Low Side (+35 air into coil) 55 PSIG REF-01 Mod. 2 3 - 4 Amps
High Pressure Safety Rated Operating Amps
Cut Out Setting 460 PSIG REF-01 Mod. 1 5 Amps
Differential 30 PSIG REF-01 Mod. 2 5 Amps
Defrost High Limit Safety Operating Voltage
Cut Out Setting REF-01 Mod. 1 120V
Differential REF-01 Mod. 2 120V
See Service Manual to Adjust Temperature
REF-01 Mod. 2 16 oz
© 2017 Franke Foodservice Solutions, Inc. This media is the confidential and proprietary property of Franke Foodservice Solutions, Inc. and shall not be reproduced in any form of media without the express written permission of Franke. Due to continuous product development, Franke reserves the right to make changes in design and specifications without prior notice. Trademarks used are the property of their respective owners. Printed in the USA under license by Franke Technology and Trademark Ltd., Switzerland.
For Support, Please Call: Tel + 1.800.5.FRANKE, opt. 2
(1.800.537.2653, opt. 2)
Outside the US:
1.615.462.3231, opt. 2
Loading...