TECHNICIAN’S QUICK REFERENCE GUIDE -
GRILL-SIDE FREEZER (GSF) GEN. 2, 30”
DOCUMENT PART NUMBER
19010023 REV A, 01-26-17
PART #’S:
18002763
(For other units, verify compatibility of parts with Technical Support before ordering)
SERVICE PARTS
ITEM # PART NUMBER DESCRIPTION QTY
1 19002864 Condensing Unit, 0.5 HP, LT, R-404A 1
2 19001820 Compressor Kit, SC12CLXN2, 115V/60Hz 1
3 3589841 Relay, Start 1
4 3589843 Capacitor, Start, 240 uF 1
5 19001942 Pressure Control, 8-32 Bar, Auto 1
6 19001809 Drier, Filter 1
7 19001253 Motor, Condenser Fan, 16W 1
8 19008909 Fan Blade, for Condenser 1
9 19000454 Motor, Evaporator Fan, with 5.5” Blade 2
10 19001190 Valve, Thermostatic Expansion, #1 1
11 3588590 Thermostat, SPST Open On Rise 1
12 19001157 Heater, Defrost, 120V/575W 1
13 19001986 Gasket, Door 1
14 19001992 Gasket, Lid 1
15 19002529 Caster, Threaded Stem, w/ Brake 4
16 19000282 Cord Set, 14/3 SJTOW, 105C Stranded 1
17 19001984 Harness, Wiring 1
NOTICE!
SERVICE PERFORMED BY NON-AUTHORIZED SERVICE PROVIDERS OR USE OF NON-OEM PARTS MAY VOID EQUIPMENT WARRANTY.
Franke Foodservice Solutions, Inc.
800 Aviation Parkway
Smyrna, TN 37167, USA
Tel + 1.800.5.FRANKE, opt. 2
(1.800.537.2653, opt. 2)
Outside the US:
1.615.462.3231, opt. 2
www.frankefs.com

TECHNICIAN’S QUICK REFERENCE GUIDE
Grill-Side Freezer (GSF) Gen. 2, 30”
SERVICE PARTS (FOR UNITS WITH ELIWELL CONTROLLERS)
18 18005969 Controller, Eliwell 1
19 19004832 Sensor, Coil Temperature, Eliwell 1
20 19004769 Sensor, Air Temperature, Eliwell 1
SERVICE PARTS (FOR UNITS WITH DANFOSS CONTROLLERS)
21 19000436 Display, Danfoss, ETP R1, with Buttons 1
22 19000468 Cable, Remote, 78”, Display ETC1H 1
23 19001093 Controller, Danfoss, ETC1H 3-Relay 1
24 19000470 Cable, Defrost Sensor, 39” 1
25 19000648 Cable, Sensor, 2200mm 1

CONTROL SETTINGS & OPERATING CHARACTERISTICS
(For Trouble Shooting Reference) Grill-Side Freezer (GSF) Gen. 2, 30”
Temperature Controller Options For More Information
Temperature Range Adjustable
Coldest Set Point -12°F
Normal Cut Out -12°F
Normal Set Point -7°F
Normal Cut In -2°F
Warmest Set Point -2°F
Compressor Protection Fixed
Minimum On Time 2 minutes
Minimum Off Time 2 minutes
Fail Safe Mode (if sensor fails) Fixed
Error On Time 10 minutes
Error Off Time 2.5 minutes
Defrost Settings Fixed
Termination Temp 60°F
Minimum Time Allowed 10 minutes
Maximum Time Allowed 90 minutes
Drip Time (heat off) 2 minutes
Defrost Based On Compressor On Time Fixed
Time Between Defrosts 3 hours
Fan Settings Fixed
During Defrost Off
Start Delay After Defrost 3 minutes
Start Delay 1 minute
Display Features Adjustments See Service Manual for Instructions
Can select degrees F or C? Yes
Can adjust temperature from display? Yes
Can Initiate Defrost from display? Yes
Display During Defrost Cycle:
Display Update Frequency 10 seconds
Refrigerant Type Amount, Ounces
R-404A FRGSF-30G2 18.5 oz
Normal Operating Pressures Normal Operating Amps
High Side (85 air to condenser) 235 PSIG FRGSF-30G2 8 - 9 Amps, 4.8 Amp Defrost
Low Side (+35 air into coil) 13 PSIG FRGSF-18G2 5 - 6 Amps, 3.8 Amp Defrost
High Pressure Safety Rated Operating Amps
Cut Out Setting 460 PSIG FRGSF-30G2 10 Amps
Differential 30 PSIG FRGSF-18G2 7 Amps
Defrost High Limit Safety Operating Voltage
Cut Out Setting 155°F FRGSF-30G2 120V
Differential 20°F FRGSF-18G2 120V
dEF Display Error Codes: E1 = Air Sensor Error, E2 = Defrost
See Service Manual for Adjusting Temperature
See Operating Manual
Sensor Error, E13 = Bad Cable/Controller Error
FRGSF-18G2 16.5 oz

© 2017 Franke Foodservice Solutions, Inc. This media is the confidential and proprietary
property of Franke Foodservice Solutions, Inc. and shall not be reproduced in any form
of media without the express written permission of Franke. Due to continuous product
development, Franke reserves the right to make changes in design and specifications
without prior notice. Trademarks used are the property of their respective owners.