Franke Foodservice FKU1008TCIXS Service Manual

HANDBOOK HOOD KUBUS FKU1008TCIXS 9925032 110.0019.381
UPDATED JANUARY 2010
MOTOR NR 01 POWER IMPUT : 340 W SPEED : 8+INTENSIVE LIGHTING : 16 W 2 NEON TOTAL POWER : 372 W FLOW RATE (FREE DELIVERY) : 810 M3/H FLOW RATE (IEC 61591) 760/670 M3/H SOUND POWER (IEC 60704-2-13) 69 IMPUT VOLTAGE : 230V 50 HZ EXIT DIAMETER 150 MM PRESSURE MAX 500 PA CONTROLS : ELECTRONIC – LOW TENSION PUSH BUTTON KEY TOUCH CONTROL
CONTENTS:
TECHNICAL DATA DRAWING ELECTRICAL CONNECTION CLEANING THE COMFORT PANELS CONTROLS HOW IT WORKS METAL GREASE FILTERS CHARCOAL FILTER SUBSTITUTION OF THE CHARCOAL FILTER CHANGING LAMP 16 W NEON LAMP LIST SPARE PARTS EXPLODED VIEW WIRING DIAGRAM
1
2
TECHNICAL DATA
3
ELECTRICAL CONNECTION
Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.
• Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan.
• Connect the control connector Cmd.
• Connect the lights connector Lux.
• Place the connectors in the junction box 24 and close it using the 2 screws 12e (2,9 x 9,5) provided.
• Fix the junction box to the hood body using the 2 screws 12c (2,9 x 6,5) provided.
• For the recirculation version, fit the activated carbon odour fil-ter.
• Replace the grease filters.
4
CLEANING THE COMFORT PANELS
• Pull the Comfort Panel to open it.
• Disconnect the panel from the hood canopy by sliding the fixing pin lever.
• The comfort panel must never be washed in a dishwasher.
• Clean the outside using a damp cloth and neutral liquid detergent.
• Clean the inside as well using a damp cloth and neutral detergent;do not use wet cloths or sponges, or jets of water; do not use abrasive substances.
• When the above operation has been completed, hook the panel back to the hood canopy and close it by turning the knob in the opposite direction.
5