TECHNICIAN’S QUICK REFERENCE GUIDE -
COMBO UNIT
DOCUMENT PART NUMBER
19010018 REV A, 02-22-17
PART #:
18009094
(For other units, verify compatibility of parts with Technical Support before ordering)
SERVICE PARTS
ITEM # PART NUMBER DESCRIPTION QTY
1 19000387 Condensing Unit, 0.5 HP, R-404A 1
2 19001076 Compressor Kit, NF7CLX, 115/60 1
3 19001081 Relay, Start, for NF7CLX, 115/60 1
4 19001084 Capacitor, Start, for NF7CLX, 115/60 1
5 19001458 Receiver, Refrigerant 1
6 3126151 Switch, Carling LTA201TRB/125N 1
7 19000152 Switch, Refrigerant Pressure Cutoff 1
8 19003675 Drier, Filter, 1/4" 1
9 3589854 Fan, Condenser Motor 1
10 19005500 Fan, Evaporator Motor 3
11 19001189 Valve, Thermostatic Expansion, #0 1
12 19007271 Gasket, Refrigerator Door 1
13 19007270 Gasket, Freezer Door 1
14 19000817 Caster, Swivel with Brake, Plate 4
15 19000282 Cord Set, 14/3 SJTOW, 105°C Stranded 1
16 19007427 Harness, Wiring 1
17 18008790 Controller, Eliwell 1
18 19004832 Sensor, Coil Temperature 1
19 19004769 Sensor, Air Temperature 2
NOTICE!
SERVICE PERFORMED BY NON-AUTHORIZED SERVICE PROVIDERS OR USE OF NON-OEM PARTS MAY VOID EQUIPMENT WARRANTY.
Franke Foodservice Solutions, Inc.
800 Aviation Parkway
Smyrna, TN 37167, USA
Tel + 1.800.5.FRANKE, opt. 2
(1.800.537.2653, opt. 2)
www.frankefs.com
CONTROL SETTINGS & OPERATING CHARACTERISTICS
(For Trouble Shooting Reference) Combo Unit
Temperature Controller Options Freezer Cooler
Temperature Range Adjustable Adjustable
Coldest Set Point (Midpoint) -6.0°F 33.0°F
Normal Cut Out -7.0°F 34.4°F
Normal Set Point (Midpoint) -5.0°F 35.5°F
Normal Cut In -3.0°F 36.5°F
Warmest Set Point (Midpoint) -1.0°F 41.0°F
Compressor Protection Fixed Fixed
Minimum On Time 2 minutes N/A
Minimum Off Time 2 minutes N/A
Fail Safe Mode (if sensor fails) Fixed Fixed
Error On Time 4 minutes 4 minutes
Error Off Time 2 minutes 6 minutes
Defrost Settings Fixed Fixed
Termination Temp 80.0°F 41.0°F
Maximum Time Allowed 30 minutes 60 minutes
Drip Time (heat off) N/A N/A
Defrost Based On Compressor On Time Fixed Fixed
Time Between Defrosts 3 hours N/A
Fan Settings Fixed Fixed
During Defrost Off N/A
Start Delay After Defrost N/A N/A
Start Delay N/A N/A
Display Features Adjustments
Can select degrees F or C? No No
Can adjust temperature from display? Yes Yes
Can Initiate Defrost from display? Yes No
Display During Defrost Cycle:
Refrigerant Type Amount, Ounces
R-404A Combo 14 oz
dEF N/A
Normal Operating Pressures Normal Operating Amps
High Side (75 air to condenser) 200 PSIG Combo 4.6 Amps
Low Side (-5 box temp) 25 PSIG
High Pressure Safety Rated Operating Amps
Cut Out Setting N/A Combo 4.6 Amps
Differential N/A
Defrost High Limit Safety Operating Voltage
Cut Out Setting N/A Combo 120V
Differential N/A
© 2017 Franke Foodservice Solutions, Inc. This media is the confidential and proprietary
property of Franke Foodservice Solutions, Inc. and shall not be reproduced in any form
of media without the express written permission of Franke. Due to continuous product
development, Franke reserves the right to make changes in design and specifications
without prior notice. Trademarks used are the property of their respective owners.
Printed in the USA under license by Franke Technology and Trademark Ltd., Switzerland.
For Support, Please Call:
Tel + 1.800.5.FRANKE, opt. 2
(1.800.537.2653, opt. 2)
Outside the US:
1.615.462.3231, opt. 2