Franke Foodservice BBR-36 18002210 Parts List

TECHNICIAN’S QUICK REFERENCE GUIDE -
BOTTLED BEVERAGE REFRIGERATOR (BBR) – 36”
DOCUMENT PART NUMBER 19010016 REV A, 01-25-17
PART #’S:
18002210
(For other units, verify compatibility of parts with Technical Support before ordering)
ITEM # PART NUMBER DESCRIPTION QTY
1 19000959 Condensing Unit, 1/4 HP, R-404A 1
2 19001079 Compressor Kit, TF4CLX 1
3 19001083 Relay Assembly, Start, with Overload, Danfoss 1
4 19001955 Capacitor, Start, Danfoss 1
5 19001458 Receiver, Refrigeration, Henry S-8002B 1
6 3126151 Switch, Carling, LTA201TRB/125N 1
7 19003675 Drier, Filter 1
8 19001189 Valve, Thermostatic Expansion, #0 1
9 19007261 Gasket, Pike Bumper, Right-Hand/Left-Hand 1
10 19002324 Gasket, Pike Sealer, Right-Hand 1
11 19002321 Spring Assembly, Door Close 2
12 19000958 Heater, Silicon Watlow, 150 Watt 1
13 3589854 Motor, Condensing Fan, 9W 1
14 19001806 Blade, Condensing Fan 1
15 19001293 Motor, Evaporator Fan, with 5.5” Blade 1
16 19000282 Cord Set 14/3 SJTOW 105°C Stranded 1
17 19006873 Loom, Wiring 1
18 19001164 Light Fixture, with Bulb 1
19 19001104 Controller, Danfoss 1
20 19001172 Cable, Temperature Sensor, Cabinet 1
21 19000470 Cable, Defrost Sensor, 39” 1
22 19001171 Cable, Remote Display 1
NOTICE!
SERVICE PERFORMED BY NON-AUTHORIZED SERVICE PROVIDERS OR USE OF NON-OEM PARTS MAY VOID EQUIPMENT WARRANTY.
Franke Foodservice Solutions, Inc. 800 Aviation Parkway Smyrna, TN 37167, USA Tel + 1.800.5.FRANKE, opt. 2
(1.800.537.2653, opt. 2)
www.frankefs.com
CONTROL SETTINGS & OPERATING CHARACTERISTICS
(For Trouble Shooting Reference) Bottled Beverage Refrigerator (BBR) - 36”
Temperature Controller Options For More Information
Temperature Range Adjustable
Coldest Set Point 33°F
Normal Cut Out (Set Point) 35°F
Normal Cut In 39°F
Warmest Set Point (Midpoint) 41°F
Compressor Protection Fixed
Minimum Time From Start to Start 2 minutes
Fail Safe Mode (if sensor fails) Fixed
Faulty Probe On Time 4 minutes
Faulty Probe Off Time 6 minutes
Defrost Settings Fixed
Termination Temp 41°F
Maximum Time Allowed 30 minutes
Drip Time (heat off) N/A
Defrost Based On Compressor On Time Fixed
Time Between Defrosts 3 hours
Fan Settings Fixed
During Defrost Off
Start Delay After Defrost N/A
Start Delay N/A
Display Features Adjustments
Can select degrees F or C? No
Can adjust temperature from display? Yes BBR-36 - See Service Manual
Can Initiate Defrost from display? Yes BBR-36 - Can be adjusted from display
Display During Defrost Cycle:
dEF
Refrigerant Type Amount, Ounces
R-404A BBR-36 16 oz
Normal Operating Pressures Normal Operating Amps
High Side (85 air to condenser) 235 PSIG BBR-36 8 - 9 Amps
Low Side (+35 air into coil) 55 PSIG BBR-45 5 - 6 Amps
High Pressure Safety Rated Operating Amps
Cut Out Setting 460 PSIG BBR-36 6.6 Amps
Differential 30 PSIG BBR-45 6.6 Amps
Defrost High Limit Safety Operating Voltage
Cut Out Setting 70°F BBR-36 120V
Differential 15°F BBR-45 120V
See Operating/Service Manual for Instructions on Adjusting Temperatures
Contact Technical Support
BBR-45 16 oz
© 2017 Franke Foodservice Solutions, Inc. This media is the confidential and proprietary property of Franke Foodservice Solutions, Inc. and shall not be reproduced in any form of media without the express written permission of Franke. Due to continuous product development, Franke reserves the right to make changes in design and specifications without prior notice. Trademarks used are the property of their respective owners. Printed in the USA under license by Franke Technology and Trademark Ltd., Switzerland.