140mm Fluid Dynamic Bearing Fan
(DYNAMIC X2 GP-14)
POWER SPECIFICATIONS
Rail3.3V5V12V5VSB-12V
Max. Power
Total Max. Power (W)860
Amps222271.630.3
Watts120860153.6
CABLES AND CONNECTORS
Modular Cables
DescriptionCable CountConnector Count (Total)GaugeIn Cable Capacitors
ATX connector 20+4 pin (600mm)1118AWGNo
4+4 pin EPS12V (700mm)1116AWGNo
8 pin EPS12V (600mm)1116AWGNo
6+2 pin PCIe (560mm+120mm)3616-18AWGNo
SATA (650mm+120mm)1218AWGNo
SATA (400mm+120mm+120mm+120mm)2818AWGNo
4 pin Molex (400mm+120mm+120mm+120mm)1418AWGNo
AC Power Cord (1400mm) - C13 coupler1116AWG-
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
PAGE 1/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 2/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
Fractal Design ION+ 860P
RESULTS
Test Date07-15-2019
Certification Date07-18-2019
Cybenetics ID #765
Temperature Range (°C /°F)30-32 / 86-89.6
Average Efficiency91.727
Efficiency With 10W (≤500W) or 2% (>500W) Load -115V49.980
Average Efficiency 5VSB76.109
Standby Power Consumption (W) -115V0.1052560
Standby Power Consumption (W) -230V0.1402120
Average PF0.961
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
Avg Noise Output17.99
Efficiency Rating (ETA)ETA-A
Noise Rating (LAMBDA)LAMBDA-A+
TEST EQUIPMENT
Chroma 63601-5 x4
Electronic Loads
AC SourcesChroma 6530, Keysight AC6804B
Power AnalyzersN4L PPA1530 x2
Sound AnalyzerBruel & Kjaer 2270 G4
MicrophoneBruel & Kjaer Type 4955-A
Data LoggersPicoscope TC-08 x2, Labjack U3-HV x2
TachometerUNI-T UT372 x2
Digital MultimeterKeysight U1273AX, Fluke 289
UPSCyberPower OLS3000E 3kVA x2
Transformer3kVA x2
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Chroma 63600-2 x2
63640-80-80 x20
63610-80-20 x2
PAGE 3/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
EFFICIENCY GRAPH
Fractal Design ION+ 860P
INFO
This graph depicts the PSU’s efficiency throughout
its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations
NOISE GRAPH
INFO
The PSU’s noise in its entire operational range and
under 30-32 °C ambient is depicted in this graph.
The X axis represents the load on the +12V rail(s)
while the Y axis is the load on the minor rails
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 4/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test #5VSB
0.046A0.231
1
5.040V0.391115.12V
0.090A0.460
2
5.106V0.683115.12V
0.550A2.798
3
5.086V3.664115.12V
1.000A5.067
4
5.066V6.587115.12V
1.500A7.566
5
5.044V9.820115.12V
DC/AC
(Watts)
EfficiencyPF/AC Volts
59.079%
67.350%
76.365%
76.924%
77.047%
0.247
0.092
0.315
0.392
0.434
Fractal Design ION+ 860P
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test #5VSB
0.046A0.231
1
5.041V0.435230.27V
0.090A0.460
2
5.106V0.733230.27V
0.550A2.798
3
5.085V3.719230.27V
1.000A5.066
4
5.065V6.616230.26V
1.500A7.564
5
5.042V9.805230.27V
DC/AC
(Watts)
EfficiencyPF/AC Volts
0.102
53.103%
0.031
62.756%
0.143
75.235%
0.221
76.572%
0.278
77.144%
6
3.000A14.914
4.971V19.486115.12V
VAMPIRE POWER -230V
76.537%
0.487
6
3.000A14.918
77.056%
4.972V19.360230.27V
0.365
INFO
This graph is generated by the PPA Standby Power
Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 5/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
Fractal Design ION+ 860P
INFO
The PSU`s efficiency under high ambient
temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used
5VSB EFFICIENCY
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
This graph depicts the efficiency levels of the 5VSB
rail with 115V and 230V input
PAGE 6/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
10-110% LOAD TESTS
Test
#
1
2
3
4
5
12V5V3.3V5VSB
5.334A1.996A2.000A1.003A85.758
12.027V5.014V3.300V4.984V96.47740.01°C230.25V
11.729A2.990A3.007A1.204A171.831
12.015V5.019V3.292V4.985V185.18740.67°C230.25V
18.471A3.497A3.498A1.410A257.747
12.004V5.007V3.290V4.967V274.87341.19°C230.26V
25.225A4.001A4.017A1.615A343.745
11.993V5.003V3.286V4.956V366.37245.50°C230.25V
31.666A4.998A5.017A1.817A429.885
11.980V5.006V3.289V4.956V458.56146.27°C230.26V
DC/AC
(Watts)
Fractal Design ION+ 860P
Fan
Efficiency
88.890%0<6.0
92.788%0<6.0
93.769%0<6.0
93.824%59112.5
93.747%59612.5
Speed
(RPM)
PSU Noise
(dB[A])
Temps
(In/Out)
42.65°C0.830
43.71°C0.927
44.63°C0.959
41.81°C0.970
42.27°C0.980
PF/AC
Volts
6
7
8
9
10
11
CL1
CL2
38.111A6.001A6.035A2.023A515.980
93.315%60212.6
11.969V5.002V3.282V4.946V552.94747.70°C230.25V
44.573A7.009A7.056A2.229A602.126
92.911%65714.6
11.958V4.996V3.274V4.936V648.06649.01°C230.25V
51.051A8.017A8.056A2.437A688.262
92.423%84822.7
11.946V4.990V3.277V4.925V744.69050.17°C230.25V
57.935A8.526A8.558A2.438A773.988
92.000%91724.9
11.935V4.987V3.273V4.924V841.28752.01°C230.26V
64.599A9.027A9.093A3.063A860.011
91.427%133536.2
11.924V4.987V3.267V4.900V940.65253.28°C230.26V
71.876A9.031A9.097A3.064A945.983
90.899%171043.0
11.913V4.985V3.265V4.897V1040.69655.02°C230.26V
0.149A14.005A14.002A0.000A117.613
84.414%0<6.0
12.003V4.996V3.275V5.054V139.32841.97°C230.27V
71.680A1.003A1.003A1.000A868.838
92.014%132736.1
11.936V4.997V3.286V4.958V944.24153.69°C230.27V
42.76°C0.984
43.09°C0.987
43.58°C0.991
44.70°C0.994
45.56°C0.996
46.72°C0.996
46.71°C0.886
45.61°C0.996
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 8/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
Top side
Power specifications label
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms)17.6
AC Loss to PWR_OK Hold Up Time (ms)16.0
PWR_OK Inactive to DC Loss Delay (ms)1.6
Fractal Design ION+ 860P
CERTIFICATIONS
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 9/9
info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.