Fractal Design Ion+ 860P User Manual

EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
DUT INFORMATION
Brand Fractal Design Manufacturer (OEM) High Power Series ION+ Model Number ION+ 860P Serial Number 1918FD19270100399 DUT Notes
DUT SPECIFICATIONS
Rated Voltage (Vrms) 100-240 Rated Current (Arms) 10-5 Rated Frequency (Hz) 50-60 Rated Power (W) 860 Type ATX12V
Cooling
Semi-Passive Operation ✓ (selectable) Cable Design Fully Modular
Fractal Design ION+ 860P
140mm Fluid Dynamic Bearing Fan (DYNAMIC X2 GP-14)
POWER SPECIFICATIONS
Rail 3.3V 5V 12V 5VSB -12V
Max. Power
Total Max. Power (W) 860
Amps 22 22 71.6 3 0.3 Watts 120 860 15 3.6
CABLES AND CONNECTORS
Modular Cables
Description Cable Count Connector Count (Total) Gauge In Cable Capacitors ATX connector 20+4 pin (600mm) 1 1 18AWG No 4+4 pin EPS12V (700mm) 1 1 16AWG No 8 pin EPS12V (600mm) 1 1 16AWG No 6+2 pin PCIe (560mm+120mm) 3 6 16-18AWG No SATA (650mm+120mm) 1 2 18AWG No SATA (400mm+120mm+120mm+120mm) 2 8 18AWG No 4 pin Molex (400mm+120mm+120mm+120mm) 1 4 18AWG No AC Power Cord (1400mm) - C13 coupler 1 1 16AWG -
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
PAGE 1/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
Fractal Design ION+ 860P
General Data
Manufacturer (OEM) High Power PCB Type Double Sided
Primary Side
Transient Filter 4x Y caps, 2x X caps, 3x CM chokes, 1x MOV,1x Discharge IC Inrush Protection NTC Thermistor & Relay Bridge Rectifier(s) 2xGBU1506 (600V, 15A @ 100°C) APFC MOSFETS 2x Infineon IPA60R099P7 (650V, 20A @ 100°C, 0.099Ohm) APFC Boost Diode 1x Infineon IDH08G65C5 (650V, 8A @ 145°C) Hold-up Cap(s) 2x Rubycon (400V, 470uF each or 940uF combined, 2,000h @ 105°C, MXH) Main Switchers 2x Infineon IPA60R099P7 (650V, 20A @ 100°C, 0.099Ohm) APFC Controller Infineon ICE3PCS01G Resonant Controllers Champion CM6901X
Topology
Primary side: Half-Bridge & LLC converter Secondary side: Synchronous Rectification & DC-DC converters
Secondary Side
+12V MOSFETS 8x Infineon BSC010N04LS (40V, 100A @ 100°C, 1mOhm)
5V & 3.3V
Filtering Capacitors
Supervisor IC SITI PS224 (OCP, OVP, UVP, SCP, PG) Micro Controller STC 15W408AS Fan Model Fractal Design DYNAMIC X2 GP-14 (140mm, 3-12V, 0.40A, Fluid Dynamic Bearing Fan ) Fan Power Transistor STi2SD882(NPN)
DC-DC Converters:8x Infineon BSC0906NS(30V, 40A @ 100°C, 4.5mOhm) PWM Controllers: ANPECAPW7159C
Electrolytics: 4x Nippon Chemi-Con (4-10,000h @ 105°C, KY), 5x Rubycon (3-6,000h @ 105°C, YXG), 1x Rubycon (6-10,000h @ 105°C, ZLH) Polymers: 31x FPCAP, 6x NIC
5VSB Circuit
Rectifier 1x PFCP10V45SPSBR (45V, 10A) & 2x InfineonBSC0906NS(30V, 40A @ 100°C, 4.5mΩ) Standby PWM Controller Excelliance MOS Corp EM8569
-12V Circuit
Rectifier KEC KIA7912PI (-12V, 1A)
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 2/9
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
Fractal Design ION+ 860P
RESULTS
Test Date 07-15-2019 Certification Date 07-18-2019 Cybenetics ID # 765 Temperature Range (°C /°F) 30-32 / 86-89.6 Average Efficiency 91.727 Efficiency With 10W (≤500W) or 2% (>500W) Load -115V 49.980 Average Efficiency 5VSB 76.109 Standby Power Consumption (W) -115V 0.1052560 Standby Power Consumption (W) -230V 0.1402120 Average PF 0.961 ErP Lot 3/6 Ready ✓ (EU) No 617/2013 Compliance ✓ Avg Noise Output 17.99 Efficiency Rating (ETA) ETA-A Noise Rating (LAMBDA) LAMBDA-A+
TEST EQUIPMENT
Chroma 63601-5 x4
Electronic Loads
AC Sources Chroma 6530, Keysight AC6804B Power Analyzers N4L PPA1530 x2 Sound Analyzer Bruel & Kjaer 2270 G4 Microphone Bruel & Kjaer Type 4955-A Data Loggers Picoscope TC-08 x2, Labjack U3-HV x2 Tachometer UNI-T UT372 x2 Digital Multimeter Keysight U1273AX, Fluke 289 UPS CyberPower OLS3000E 3kVA x2 Transformer 3kVA x2
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Chroma 63600-2 x2 63640-80-80 x20 63610-80-20 x2
PAGE 3/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
EFFICIENCY GRAPH
Fractal Design ION+ 860P
INFO
This graph depicts the PSU’s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations
NOISE GRAPH
INFO
The PSU’s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 4/9
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test # 5VSB
0.046A 0.231
1
5.040V 0.391 115.12V
0.090A 0.460
2
5.106V 0.683 115.12V
0.550A 2.798
3
5.086V 3.664 115.12V
1.000A 5.067
4
5.066V 6.587 115.12V
1.500A 7.566
5
5.044V 9.820 115.12V
DC/AC (Watts)
Efficiency PF/AC Volts
59.079%
67.350%
76.365%
76.924%
77.047%
0.247
0.092
0.315
0.392
0.434
Fractal Design ION+ 860P
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test # 5VSB
0.046A 0.231
1
5.041V 0.435 230.27V
0.090A 0.460
2
5.106V 0.733 230.27V
0.550A 2.798
3
5.085V 3.719 230.27V
1.000A 5.066
4
5.065V 6.616 230.26V
1.500A 7.564
5
5.042V 9.805 230.27V
DC/AC (Watts)
Efficiency PF/AC Volts
0.102
53.103%
0.031
62.756%
0.143
75.235%
0.221
76.572%
0.278
77.144%
6
3.000A 14.914
4.971V 19.486 115.12V
VAMPIRE POWER -230V
76.537%
0.487
6
3.000A 14.918
77.056%
4.972V 19.360 230.27V
0.365
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 5/9
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
Fractal Design ION+ 860P
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used
5VSB EFFICIENCY
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input
PAGE 6/9
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
10-110% LOAD TESTS
Test #
1
2
3
4
5
12V 5V 3.3V 5VSB
5.334A 1.996A 2.000A 1.003A 85.758
12.027V 5.014V 3.300V 4.984V 96.477 40.01°C 230.25V
11.729A 2.990A 3.007A 1.204A 171.831
12.015V 5.019V 3.292V 4.985V 185.187 40.67°C 230.25V
18.471A 3.497A 3.498A 1.410A 257.747
12.004V 5.007V 3.290V 4.967V 274.873 41.19°C 230.26V
25.225A 4.001A 4.017A 1.615A 343.745
11.993V 5.003V 3.286V 4.956V 366.372 45.50°C 230.25V
31.666A 4.998A 5.017A 1.817A 429.885
11.980V 5.006V 3.289V 4.956V 458.561 46.27°C 230.26V
DC/AC (Watts)
Fractal Design ION+ 860P
Fan
Efficiency
88.890% 0 <6.0
92.788% 0 <6.0
93.769% 0 <6.0
93.824% 591 12.5
93.747% 596 12.5
Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
42.65°C 0.830
43.71°C 0.927
44.63°C 0.959
41.81°C 0.970
42.27°C 0.980
PF/AC Volts
6
7
8
9
10
11
CL1
CL2
38.111A 6.001A 6.035A 2.023A 515.980
93.315% 602 12.6
11.969V 5.002V 3.282V 4.946V 552.947 47.70°C 230.25V
44.573A 7.009A 7.056A 2.229A 602.126
92.911% 657 14.6
11.958V 4.996V 3.274V 4.936V 648.066 49.01°C 230.25V
51.051A 8.017A 8.056A 2.437A 688.262
92.423% 848 22.7
11.946V 4.990V 3.277V 4.925V 744.690 50.17°C 230.25V
57.935A 8.526A 8.558A 2.438A 773.988
92.000% 917 24.9
11.935V 4.987V 3.273V 4.924V 841.287 52.01°C 230.26V
64.599A 9.027A 9.093A 3.063A 860.011
91.427% 1335 36.2
11.924V 4.987V 3.267V 4.900V 940.652 53.28°C 230.26V
71.876A 9.031A 9.097A 3.064A 945.983
90.899% 1710 43.0
11.913V 4.985V 3.265V 4.897V 1040.696 55.02°C 230.26V
0.149A 14.005A 14.002A 0.000A 117.613
84.414% 0 <6.0
12.003V 4.996V 3.275V 5.054V 139.328 41.97°C 230.27V
71.680A 1.003A 1.003A 1.000A 868.838
92.014% 1327 36.1
11.936V 4.997V 3.286V 4.958V 944.241 53.69°C 230.27V
42.76°C 0.984
43.09°C 0.987
43.58°C 0.991
44.70°C 0.994
45.56°C 0.996
46.72°C 0.996
46.71°C 0.886
45.61°C 0.996
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 7/9
info@cybenetics.com
EFFICIENCY AND NOISE LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
20-80W LOAD TESTS
Test # 12V 5V 3.3V 5VSB
1.201A 0.498A 0.485A 0.199A 19.630
1
12.092V 5.029V 3.306V 5.024V 31.798 230.25V
2.472A 0.998A 1.000A 0.400A 40.050
2
12.031V 5.015V 3.303V 5.003V 49.821 230.25V
3.669A 1.497A 1.483A 0.601A 59.534
3
12.027V 5.015V 3.302V 4.998V 69.950 230.25V
4.933A 1.995A 1.999A 0.801A 79.937
4
12.028V 5.015V 3.301V 4.993V 90.616 230.25V
RIPPLE MEASUREMENTS
DC/AC (Watts)
Fractal Design ION+ 860P
Efficiency
61.733% 0 <6.0
80.388% 0 <6.0
85.109% 0 <6.0
88.215% 0 <6.0
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
0.533
0.651
0.751
0.818
Test 12V 5V 3.3V 5VSB Pass/Fail
10% Load 11.4 mV 8.0 mV 10.5 mV 9.4 mV Pass 20% Load 8.6 mV 8.4 mV 10.9 mV 9.8 mV Pass 30% Load 9.0 mV 10.5 mV 11.4 mV 11.2 mV Pass 40% Load 10.3 mV 9.8 mV 11.8 mV 11.7 mV Pass 50% Load 12.5 mV 27.7 mV 33.8 mV 25.0 mV Pass 60% Load 12.5 mV 11.4 mV 13.8 mV 13.1 mV Pass 70% Load 13.5 mV 12.0 mV 13.4 mV 13.8 mV Pass 80% Load 15.2 mV 11.9 mV 13.9 mV 14.6 mV Pass 90% Load 15.1 mV 12.9 mV 14.9 mV 14.7 mV Pass 100% Load 19.8 mV 13.2 mV 15.2 mV 17.0 mV Pass 110% Load 21.0 mV 13.7 mV 16.8 mV 17.4 mV Pass Crossload 1 15.7 mV 10.0 mV 13.1 mV 10.8 mV Pass Crossload 2 19.7 mV 12.8 mV 14.3 mV 16.2 mV Pass
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 8/9
info@cybenetics.com
EFFICIENCY AND NOISE
Top side
Power specifications label
LEVEL CERTIFICATIONS
www.cybenetics.com
Evaluation Report
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms) 17.6 AC Loss to PWR_OK Hold Up Time (ms) 16.0 PWR_OK Inactive to DC Loss Delay (ms) 1.6
Fractal Design ION+ 860P
CERTIFICATIONS
All data and graphs included in this test report can be used by any individual on the following conditions: › It should be mentioned that the test results are provided by Cybenetics › The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient and silent power supplies are promoted
PAGE 9/9
info@cybenetics.com