80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
10-5 Amps
50-60 Hz
660 Watts
Note: All measurements were taken with input voltage at 115 V nominal at 60 Hz. Input AC Current Waveform (ITHD = 3.21%, 50% Load)
0.69 0.95 21.50% 10% 75.90 12.06/0.03 3.31/1.11 4.99/1.11 4.98/0.25 66.20 87.21%
1.28 0.98 15.27% 20% 144.50 11.88/0.05 3.31/2.22 4.99/2.21 4.99/0.5 132.23 91.51%
3.12 1.00 3.21% 50% 357.30 11.49/0.13 3.31/5.55 5.03/5.5 5/1.26 330.10 92.39%
6.35 1.00 3.20% 100% 728.70 11.86/0.25 3.37/11.11 5.03/10.98 4.96/2.51 658.63 90.38%
12V (cumulative of 12V1, 12V2, etc.)
DC Terminal Voltage (V)/ DC Load Current (A)
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0% 25% 50% 75% 100% 125%
Efficiency (%)
Loading (% of Rated Output Power)
Efficiency of the Power Supply
Efficiency
Input Watts
Output Watts
0
100
200
300
400
500
600
700
800
20% 50% 100%
Power (Watts)
Loading (% of Rated Output Power)
Input and Output Power
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient
power supplies (greater than 80% efficiency in the active mode) in technology
applications. http://www.80plus.org/
-60.0
-40.0
-20.0
0.0
20.0
40.0
60.0
-200
-100
0
100
200
-0.001 0.003 0.008 0.013
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current