Thank you for your purchase of the Fowler Xtra-Value Cal Electronic Caliper. Please carefully review this instruction manual to insure proper and accurate use of your new instrument.
IMPORTANT!
2. Never apply voltage (e.g. engraving with an electric engraver) on any part of the caliper for fear of damaging
the circuit.
3. After use, take corrosion prevention measures such as a very ne clock oil.
Internal Jaws
Hold
External Jaws
Zero
Battery Cover
Beam
Depth Measurement Rod
Thumbroll
in/mm Locking screw
LCD display
Functions and Features
Turn on the caliper by moving the measuring carriage. Auto switch off after several minutes.
Zero Setting: Press <zero> function button
Changing Measuring Standard: Press <inch/mm> function button to toggle between in/mm
Absolute/Incremental: Press <abs> button, to return to zero function press button again
Hold: Press once to freeze display reading. Press again to resume measuring
Operating Instructions and Parts Manual Model No: 54-101-150-2 74-101-150-2
SEE REVERSE FOR FURTHER INSTRUCTIONS
Cleaning
Clean the caliper with a soft cloth and a few drops of ne clock oil. DO NOT use any type of sol­vent. DO NOT immerse the caliper in liquid.
Battery Replacement
• Slide off the battery cover, then remove the battery by gently tapping the instrument in your hand (Never try to force or pry the battery out). Insert the new battery with the positive pole "+" facing upwards and replace the cover
• Please dispose of used batteries at a proper collection center.
Electronic Caliper
®
ABS
Measuring Range: Resolution: Accuracy: Repeatability: Measuring System: Display: Maximum Measuring Speed: Battery:
Battery Life: Operational Temperature Range: Maximum Relative Humidity:
0-6"/150mm
.0005"/.01mm
±.001"/.02mm .0005"/.01mm
Capacitive
LCD 8.0 mm high
120" per second
3V, CR2032 Lithium Battery
#54-100-350-0
Approximately 1 year
0°C to +40°C
80%
CAUTION
• DO NOT disassemble, short-circuit, charge, or heat the battery.
• The outside and inside measuring jaws of this caliper have sharp edges, handle it with great care.
TO AVOID INJURY
Fowler High Precision, Inc.
66 Rowe Street • Newton, MA 02466 1-800-788-2353 • Fax: 617-332-4137 Internet: www.fowlerprecision.com • E-mail: sales@fowlerprecision.com
Symptom
• Digits do not change or count correctly
• No Display
Corrective Action
• Remove the battery for 30 seconds then reinstall.
• Check battery contacts or replace battery.
RESET: In order to RESET the instrument, remove the battery, wait 30 seconds, replace the battery and
turn the instrument on.
Precautions: Although a top quality product, certain precautions are required for any electronic instrument:
• Avoid exposure to all liquids and excessive humidity.
• Avoid exposure to electromagnetic elds.
• Do not expose the instrument to direct sunlight.
• Do not attempt to disassemble the caliper.
Technical Data
Troubleshooting Chart
Electronic Caliper
®
Operating Instructions and Parts Manual Model No: 54-101-150-2 74-101-150-2