Fostex DE-1 Service Manual

Service Manual
Model
DE-1
20-bit Dual Multi Effect Processors
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION:
TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLOT, FULLY INSERT.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The lightening flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product's en­closure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
“WARNING”
“TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOIS­TURE.”
SAFETY INSTRUCTIONS
Read instructions - All the safety and operating instruc-
1. tions should be read before the appliance is operated. Retain instructions - The safety and operating instructions
2. should be retained for future reference. Heed warnings - All warnings on the appliance and in the
3. operating instructions should be adhered to. Follow instructions - All operating and use instructions
4. should be followed. Water and Moisture - The appliance should not be used
5. near water - for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, and the like. Carts and Stands - The appliance should be used only
6. with a cart or stand that is recommended by the manufac­turer.
An appliance and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause the appliance and cart combination to over­turn. Wall or Ceiling Mounting - The appliance should be
7. mounted to a wall or ceiling only as recommended by the manufacturer. Ventilation - The appliance should be situated so that its
8. location or position does not interfere with its proper ven­tilation. For example, the appliance should not be situ­ated on a bed, sofa, rug, or similar surface that may block the ventilation openings; or, placed in a built-in installa­tion, such as a bookcase or cabinet that may impede the flow of air through the ventilation openings.
ATTENTION:
POUR ÉVITER LES CHOCS ÉLECTRIQUES, INTRODUIRE LA LAME LA PLUS LARGE DE LA FICHE DANS LA BORNE CORRE­SPONDANTE DE LA PRISE ET POUSSER JUSQU' AU FOND.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and mainte­nance (servicing) instructions in the literature accompanying the appliance.
Heat - The appliance should be situated away from heat
9. sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat. Power Sources - The appliance should be connected to a
10. power supply only of the type described in the operating instructions or as marked on the appliance. Grounding or Polarization - The precautions that should
11. be taken so that the grounding or polarization means of an appliance is not defeated. Power Cord Protection - Power supply cords should be
12. routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience recep­tacles, and the point where they exit from the appliance. Cleaning - The appliance should be cleaned only as rec-
13. ommended by the manufacturer. Nonuse Periods - The power cord of the appliance should
14. be unplugged from the outlet when left unused for a long period of time. Object and Liquid Entry - Care should be taken so that
15. objects do not fall and liquids are not spilled into the en­closure through openings. Damage requiring Service - The appliance should be ser-
16. viced by qualified service personnel when:
The power supply cord or the plug has been damaged;
A.
or Objects have fallen, or liquid has been spilled into the
B.
appliance; or The appliance has been exposed to rain; or
C.
The appliance does not appear to operate normally or
D.
exhibits a marked changed in performance; or The appliance has been dropped, or the enclosure
E.
damaged.
Servicing - The user should not attempt to service the ap-
17. pliance beyond that described in the operating instruc­tions. All other servicing should be referred to qualified service personnel.
TABLE OF CONTENTS
DE-1
1. SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2. CONTROLS, INDICATORS AND CONNECTORS . . . . . . . . . . . .
3. EXPLODED VIEW, PCB ASSEMBLY AND PARTS LIST . . . . . .
4. CIRCUIT & BLOCK DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . .
4 5 6
14
NOTES
* Parts List and circuit diagrams are given in this manual to assist the service technician in maintaining the Model DE-1. * The following accessories are supplied with DE-1 as the standard accessories.
Owner's manual : 8288441100 (for domestic & export model) Foot assy, S : 8260561000
* Following is the packing material for the Model DE-1.
Packing, L, DE-1 : 8228454000 Packing, R, DE-1 : 8228455000 Carton, inner, DE-1 : 8228729000
CAUTION
Parts marked with this sign are safety critical components. They must always be replaced with identical components. Refer to the Fostex Parts List and ensure exact replacement.
3
DE-1
1. SPECIFICATIONS
INPUT & OUTPUT
INPUT (x 2)
Connector 6 mm phone jack / unbalanced Input level -10 dBV Impedance 20 k or more
STEREO OUTPUT (L & R)
Connector 6 mm phone jack / unbalanced Output level -10 dBV Impedance 10 k or more
FOOT SWITCH (x 1) 6 mm phone jack (Optional Model 8051)
OTHERS
Frequency Response + 1, -2 dB at 20 Hz ~ 14.5 kHz Dynamic Range 86 dB (IHF A) AD / DA Converter 20-bit Total Harmonic Distortion 0.1 % at 100 Hz ~ 10 kHz (w / LPF) Crosstalk 60 dB at 1 kHz Sampling Frequency 32 kHz
GENERAL
Dimensions 220 (W) × 187 (D) × 43 (H) mm Weight 1.0 kg (excluding AC adaptor) Power Requirement
JPN 100 V AC USA / CND 120 V AC
UK / EUR 230 V AC Power supply DC 9 V (center: positive), 600 mA AC Adaptor AD-9B
STANDARD ENVIRONMENT
Standard Temperature 20 ± 2 ºC Standard Humidity 65 ± 5 %
ENVIRONMENT CONDITION
Characteristics Guaranteed
Temperature + 5 ºC ~ + 40 ºC
Humidity 30 ~ 70 %
AC voltage deviation ± 5 % or less Operation Guaranteed
Temperature +- 5 ºC ~ + 45 ºC
Humidity 85 % or less
AC voltage deviation ± 10 % or less
* Specifications and appearance are subject to change without notice for product improvement.
4
2. CONTROLS, INDICATORS & CONNECTORS
< Front Panel >
DE-1
EFFECT 1
TYPE
DLY+REV VOCAL PLATE MISC
ROOM S.HALL
L.HALL
VARIATION
DELAY
CHO
PITCH
FLANGE
6 5 4
3 2
11
PEAK
ADJUST
PARAM.1
7 8
9
10 1
4312 65 1097 8 11 12
< DUAL MODE >
1. EFFECT 1 TYPE SW
2. EFFECT 1 VARIATION SW
3. PEAK LED
4. EFFECT 1 ADJUST knob
5. EFFECT 1 MIX knob
6. MODE SW
< SINGLE MODE >
1. TYPE SW
2. VARIATION SW
3. PEAK LED (L channel)
4. PARAM. (PARAMETER) 1 knob
5. MIX knob
6. MODE SW
MIX
DRY+EFF DRY+EFF
MODE
DRY
SINGLE DUAL
EFF
VOCAL PLATE
ROOM S.HALL
L.HALL
TYPE
DLY+REV
FLANGE
DELAY
MISC
CHO
PITCH
5 4
3 2
1
VARIATION
6
PEAK
ADJUST
PARAM.2
7 8
9
10 1
1
DRY
_
7. EFFECT 2 TYPE SW
8. EFFECT 2 VARIATION SW
9. PEAK LED
10. EFFECT 2 ADJUST knob
11. EFFECT 2 MIX knob
12. POWER LED
7. Not functioning
8. Not functioning
9. PEAK LED (R channel)
10. PARAM. (PARAMETER) 2 knob
11. PARAM. (PARAMETER) 3 knob
12. POWER LED
EFFECT 2
MIX
PARAM.3
EFF
+
POWER
< Rear Panel >
9V
AD-9B
ONLY
DC IN
13
< DUAL MODE >
13. DC INLET socket
14. Foot SW socket
15. OUTPUT 2 jack sockets
16. OUTPUT 1 jack sockets
< SINGLE MODE >
13. DC INLET socket
14. Foot SW socket
15. Not functioning
16. Not functioning
EFF MUTE
FOOT SW
14
OUTPUT 2
15
L (MONO)R
R
L (MONO)
OUTPUT 1
2
R
DUAL MODE
SINGLE MODE
MAXMIN MIN MAX
INPUT
1 (1&2)
L (MONO)
16 17 18 19
17. INPUT 2 jack socket
18. INPUT 1 (1 & 2) jack socket
19. INPUT LEVEL knobs
17. INPUT L (MONO) jack socket
18. INPUT R jack socket
19. INPUT LEVEL knobs
5
DE-1
3. EXPLODED VIEW, PCB ASSEMBLY AND PARTS LIST
DE-1 OVERALL EXPLODED VIEW & PARTS LIST
Ref. No. Part No. Description
1 8221287000 Panel, front, DE-1 2 8221288000 Panel, top, DE-1 3 8221289000 Chassis, VC-8/DE-1 4 8274207000 PCB assy, Main, DE-1 5 8274208000 PCB assy, DSP, DE-1 6 8221292000 Bracket, volume, DE-1 7 8216700100 Shield, EMI, DE-1 8 8216702000 Sheet, screw, DE-1
9 8226189001 Knob, volume, grey, N 10 8226190001 Knob, volume, green, N 11 8226191001 Knob, volume, blue, N 12 8270818003 AC adaptor, AD-9B, USA/CSA
8270818006 AC adaptor, AD-9B, EUR 8270818007 AC adaptor, AD-9B, UK 8270818010 AC adaptor, AD-9B, JPN