Foster EP700HH, EP700H2BK, EP700HBK, EP700HL, EP700G Original Operation Instructions

...
By Appointment to
Her Majesty Queen Elizabeth II
Suppliers of Commercial Refrigeration
Foster Refrigerator, Kings Lynn
Call: +44 (0)843 216 8800 Fax: +44 (0)843 216 4700 Email: support@foster-uk.com
www.fosterrefrigerator.co.uk
A Division of ITW Ltd
Oldmedow Road
King’s Lynn
Norfolk, PE30 4JU
United Kingdom
ISO 9001 ISO 14001
English
Original Operation Instructions
EcoPro G2
Cabinet & Counter Models
00-556483 August 2016 Issue 7 GB
Controller & Display - Versions FD1-11 & FD1-14
1
Single Cabinets
EP700F EP700G EP700H EP700H2 EP700H2BK EP700HBK EP700HH EP700HL EP700HSTB EP700HU EP700HMH EP700P EP700W
EP700L EP700L2 EP700L2BK EP700LBK EP700LL EP700LSTB EP700LU EP700LHM
EP700M EP700M2 EP700MU
G700G G700H G700L G700M G700W
Double Cabinets
EP1440G EP1440H EP1440H4
EP1440HSTB EP1440HU
EP1440W
EP1440L EP1440L4
EP1440LSTB EP1440LU
EP1440M EP1440M4 EP1440MU
G1440H G1440L G1440M
Broadway
EP820HU EP820LU
Workout
EP820MW EP820LW
Counters
EP1/2G EP1/2H EP1/2L EP1/2M EP1/2P
EP1/3G EP1/3H EP1/3L EP1/3M EP1/3P
EP1/4G EP1/4H EP1/4L EP1/4M
EP2/2H
EP2/3H
Models Applicable to This Manual
GB
2
General Electrical Safety
Foster Refrigerator recommends that the equipment is electrically connected via a Residual Current Device; such as a Residual Current Circuit Breaker (RCCB) type socket, or through a Residual Current Circuit Breaker with Overload Protection (RCBO) supplied circuit.
Disposal Requirements
If not disposed of properly all refrigerators have components that can be harmful to the environment. All old refrigerators must be disposed of by appropriately registered and licensed waste contractors, and in accordance with national laws and regulations.
Start-Up and Operation
After unpacking, clean and allow the cabinet or counter to stand for 2 hours before turning on (cleaning directions supplied within this manual). Ensure the cabinet is situated on a rm, level surface away from both
hot and cold air sources, as this will affect its performance.
Vaporiser Tray (Dual Temperature Models Only)
On delivery, the tray is attached to the rear of the cabinet. Remove the two xing screws and slide the vaporiser tray underneath the cabinet, into the two xed runners.
Bend the corner tabs of the tray upwards, then using the guide holes already in the cabinet secure the tray in position with the two screws originally removed. The heaters electrical connection to the cabinet will already be in place. Ensure the drain line pipe is angled in an upright position to form an air lock.
Please make sure that when positioning a dual temperature model with an external vaporiser tray the tray does
not come into contact with any other surfaces.
Clearance (All models)
Make sure that a minimum clearance of 310mm above and 50mm around the cabinet or counter is available for ventilation and effective operation.
Connect the unit to a suitable mains power outlet and turn the supply on. Please do not plug or unplug the unit with wet hands.
The cabinet will energise briey showing followed by the power switch slowly pulsing with a blank display.
The unit is now in standby.
Standby
Pressing the power switch for 3 seconds will turn the unit on (the switch backlight is static and the display shows the operating temperature) or into standby (the switch backlight pulses slowly on and off).
As the operating temperature has been preset no adjustments are required. Allow the cabinet to reach its normal/ set operating temperature before loading.
Important Note to the Installer:
Please ensure that this document is passed to the user as it contains important guidelines on operation, loading, cleaning and general maintenance and should be kept for reference.
GB
3
GB
Display Icons and Switches
(Some icons or switches are only visible during adjustment, when activated by parameters or through operation/
manual selection).
User Adjustment Mode
You are required to enter this mode to make any setup changes. These include Set Point, Keypad Security and display of T1, 2 or 3 probe temperatures.
Press and immediately release after which the and switches will ash/pulse together.
Press to scroll through the following screens:
(Cabinet Version)
Keypad Lock Warning/ Alarm
Service Mode Temperature Setting
Compressor Function Defrost Function
Evaporator Fan Function Reduced Energy Mode
Data Download Switch Light Switch
Decrease Switch Increase Switch
Power Switch
(Counter Version)
Loading...
+ 8 hidden pages