FossLED FD05PT-00, FD05PT-11 User guide

Page 1
Arco
GU10 Tilt Trimless Downlight FD05PT-00/11
fossLED open construction fire rated glass fixtures feature a low profile for installation versatility and good air circulation for improved lamp lifetime.
Fire Rated to 30 minutes, 60 minutes and 90 minutes when installed in ceilings of approved construction to BS 476: Part 21:1987.
IP20 rating, dust resistant only, no resistance to moisture or water.
This product must be installed by a qualified electrician in accordance with instructions provided and in compliance with recognised electrical and safety regulations relevant to the country it is being installed.
This product must not be used with non-LED lamps and installed with a max lamp wattage of 7W.
This product is for indoor use only.
Minimum clearance is 50mm above the installed fitting and should NOT be installed within 200mm of any joist.
This light fitting should be connected to a circuit with a 30mA RCD when fitted in a room containing a bath or shower.
Avoid the installation of cables in locations that would cause a hazard. Position cables away from areas where there may be at risk of them being trapped, damaged or cut.
www.fossled.com
Page 2
68mm
28mm
68mm
75mm
102mm
28mm
DIMENSIONS:
Ø68mm
68mm
28mm
102mm
102mm
When installed in conjunction with our ‘Insulation bracket’ (Sold Seprately) this product is suitable for coverage by thermal and acoustic insulation e.g. loft insulation. Not suitable for blown insulation. Please ensure a max wattage of 7W when covering with insulation and utilising the insulation bracket.
MIN
150mm
MIN 200mm MIN 200mm
If installing without an insulation bracket please ensure any insulation is at a minimum distance of 150mm away from the fixture / lamp and not covering it.
MIN
150mm
MIN 150mm
MIN 200mm
MIN 150mm
MIN 200mm
Page 2Arco FD05PT Product Manual
Page 3
INSTALLATION:
1
Ensure mains power is turned OFF and cannot be unexpectedly reconnected.
3
2
Ø68mm
For new installations use suitable cutting tools and carefully cut the required hole.
It is advised to test the tilt angle / direction by fitting the fixture together at this stage. Fit by pushing the fixture together making sure it is axially aligned.
4
Fit the plaster fixture in the orientation as per step 3. Secure in place with a minimum of 6 screws.
Check the tilt angle / direction desired. Now disassemble the fixture.
Plaster up to the plaster lip for a seamless finish.
Page 3Arco FD05PT Product Manual
Page 4
5
6
When wiring please ensure you have identified the correct wiring from the circuit and ensure the connections are tight and no loose strands have been left outside of the connection block.
Fit the LED bulb into the fixture, then twist and connect your LED bulb. Finally fit the inner fixture making sure the tilt angle / direction is set as per step 3.
0.5m
IP20
Compliant to all applicable UKCA Directive requirements.
Compliant to all applicable EC Directive requirements.
Please do not dispose of along with household waste. Waste electrical products should only be recycled using a suitable local recycling facility. Contact your local authority for recycling advice.
Do NOT directly mount this product on normally flammable surfaces. The product should be mounted on non-combustible surfaces.
A minimum distance of 0.5 metres from lighted objects.
The power supply is double insulated and so does not require an Earth connection.
This product is dust resistant only, no resistance to moisture or water.