Fortinet FortiGate FortiGate-ADM-XB2 Quick Start Manual

© Copyright 2007 Fortinet Incorporated. All rights reserved. Products mentioned in this document are trademarks or registered trade­marks of their respective holders. Regulatory Compliance FCC Class A Part 15 CSA/CUS 7 September 2007
Installing the transceivers
Installing the AMC module
QuickStart Guide
FortiGat e-ADM-XB2
Copyright 20 07 Fortinet Incorporat ed. All rig hts reserve d.
Trademarks Products men tioned in t his documen t are trade marks.
Q ui c k St a rt G ui d e
x2 XFP Transceivers
ADM-XB 2
LINK
ACT
1
2
HS
OOS
PWR
OT
LINK
ACT
ADM-XB2
LINK
ACT
1 2
HS
OOS
PWR
OT
LINK
ACT
ADM-XB2
LINK
ACT
1
2
HS
OOS
PWR
OT
LINK
ACT
The FortiGate ADM-XB2 module ships with two XFP transceivers that you must install for nor­mal operation of the FortiGate ADM-XB2 module. The XFP transceivers are inserted into cage sockets numbered 1 and 2 on the FortiGate ADM-XB2 front panel. You can install the SFP transceivers before or after inserting the FortiGate ADM-XB2 module into a FortiGate unit.
To complete this procedure, you need:
• A FortiGate- ADM-XB2 module
• Two XFP transceivers
• To avoid any electrostatic discharge, install in a static free area.
FortiGate ADM-XB2 modules must be protected from static discharge and physical shock. Only handle or work with FortiGate ADM-XB2 modules at a static-free workstation.
Handling the XFP transceivers by holding the release Latch can damage the connector. Do not force the XFP transceivers into the cage slots. If the transceiver does not easily slide in and click into place, it may not be aligned correctly or
It is important to carefully seat the FortiGate ADM-XB2 module all the way into the chassis. Only then will the FortiGate ADM-XB2 module power-on and start up correctly.
To complete this procedure, you need:
• A FortiGate ADM-XB2 module
• A FortiGate chassis with an empty AMC double-width (DW) opening.
• To avoid any electrostatic discharge, install in a static free area.
FortiGate ADM-XB2 modules are not hot swappable. The procedure for inserting the FortiGate ADM-XB2 module into a FortiGate chassis slot requires the FortiGate unit to be powered off.
FortiGate ADM-XB2 modules must be protected from static discharge and physical shock. Only handle or work with FortiGate ADM-XB2 modules at a static-free workstation.
To insert a FortiGate ADM-XB2 module into a FortiGate chassis
Ensure the FortiGate unit is powered off before proceeding.
Attach an ESD wrist or ankle strap to your wrist or ankle and to an ESD socket or to a bare metal surface on the chassis or frame.
Remove the panel block on the FortiGate unit using the hot swap latch.
Insert the FortiGate ADM-XB2 module into the empty slot in the chassis. Ensure the Fortinet logo is right-side up. It should be on the upper-right corner of the module
Carefully guide the module into the chassis.
Pull out the hot swap latch on the right-hand side of the module to the extended position if it is pushed in.
Insert the module by applying moderate force to the front faceplate near the upper edge to slide the module into the slot.
1.
2.
3.
4.
5.
6.
7.
FortiGate-ADM-XB2
01-30005-0415-20070907
Connector Type Speed Protocol Description
Ports 1 and 2 XFP - SGMII Fiber Ethernet Fiber network connections.
may be upside down. If this happens, remove the XFP transceiver, realign it or rotate it and slide it in again.
To Install the transceivers
Remove the caps from XFP cage sockets on the FortiGate ADM-XB2 front panel.
Hold the sides of the XFP transceiver and slide XFP transceiver into the cage socket until it clicks into place.
1.
2.
The module should glide smoothly into the chassis. If you encounter any resistance while sliding the module in, the module could be aligned incorrectly. Pull the module back out and try inserting it again.
Press the hot swap latch rmly to lock in the module.
Power on the FortiGate unit. The hot swap (HS) LED turns on and then begins ashing.
After a few minutes the HS LED will turn off. If the module is operating correctly the PWR LED will stay lit.
ASM-XB2 module ports
AMC/1 IP: ____.____.____.____ AMC/2 IP: ____.____.____.____
Netmask: ____.____.____.____ Netmask: ____.____.____.____
Removing the AMC module
Should you need to remove the ADM-XB2, shut down the FortiGate unit using proper shut down procedures.
To remove the ADM-XB2 module
Ensure the FortiGate unit is powered off before proceeding.
To avoid any electrostatic discharge (ESD) when handling FortiGate ASM-XB2 modules, install in a static free area.
Pull the hot swap latch on the right-hand side of the module to unlock the module to the extended position to unlock the module from the FortiGate unit.
Gently pull the hot swap latch to remove the module.
8.
9.
1.
2.
3.
4.
LED State Description
HS
Blue Ejection latch open.
Flashing Ejection latch opened during system operation.
OOS LED currently not in use.
PWR
Amber The module is properly inserted in the FortiGate unit.
Off The module is not receiving power from the FortiGate unit.
OT LED currently not in use.
LINK
Green The correct cable is in use and the connected equipment has power.
Off No link established.
ACT
Flashing Green Network activity at this interface.
Off No network activity at this interface.
Loading...