Follett HCD1810RBT, HCF1810RBT, HCD2110NBT, HCF2110RBT Installation Manual

Page 1
Horizon Elite™ Ice Machine Installation Instructions
for Ice Storage Bin Top-mount Applications
HCD/HMD/HCF/HMF1810RBT, HCD/HMD/HCF/HMF2110RBT, HCD1810NBT, HMD1810NBT, HCD2110NBT, HMD2110NBT
Order parts online www.follettice.com
remote condensing
801 Church Lane • Easton, PA 18040, USA Toll free (877) 612-5086 • +1 (610) 252-7301 www.follettice.com
01157908R01
Page 2
Chewblet® Ice Machine Model Number Configurations
HC 1810D SVA
CondenserSeriesVoltageIcemaker
MC Maestro™
Chewblet (425 Series)
HC Horizon
Chewblet (710, 1010, 1410, 1810, 2110 Series)
HM Horizon
Micro Chewblet
C 208-230/60/1 (icemaking head)
®
Self-contained only.
D 115/60/1 (icemaking head)
Self-contained and remote. If remote unit, high side is 208-230/60/1.
E 230/50/1 (icemaking head)
Self-contained only.
F 115/60/1 (icemaking head)
Remote only. High side is 208-230/60/3.
425 up to
425 lbs (193 kg)
710 up to
675 lbs (306 kg)
1010 up to
1061 lbs (482 kg)
1410 up to
1466 lbs (665 kg)
1810 up to
1790 lbs (812 kg)
2110 up to
2039 lbs (925 kg)
A Air-cooled, self-contained W Water-cooled, self-contained R Air-cooled, remote condensing unit N Air-cooled, no condensing unit for
connection to parallel rack system
V Vision™ H Harmony™ B Ice storage bin J Drop-in M Ice Manager
diverter valve system
P Cornelius Profile
PR150
S RIDE™
T Top-mount
CAUTION!
§ This appliance should be connected by a qualied person in accordance with applicable codes.
§ If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualied persons in order to avoid a hazard.
§ Connect to potable water supply only.
§ This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children should be supervised to ensure that they do not play with the appliance.
§ This appliance is intended to be used for household and similar applications such as staff kitchen areas in shops, offices and other working environments; farm houses and by clients in hotels, motels and other residential type environments; bed and breakfast type environments; catering and similar non-retail applications.
§ WARNING! To avoid a hazard due to instability of the appliance, it must be xed in accordance with the instructions.
ConfigurationApplication
(RIDE remote ice delivery equipment)
2
remote condensing BIN • TOP-MOUNT
Page 3
Read and complete the following 8 installation steps
Unpack
1
Bin preparation
3
Ice transport tube
5
Site preparation
2
Louvered docking assembly
4
External connection
6
Internal connection
7
Front cover
8
BIN • TOP-MOUNT remote condensing
3
Page 4
Carefully unpack and inspect the contents of your Follett ice machine.
Unpack
1
1. 1
Unpack ice machine
7/16"
DO NOT TILT ICE MACHINE TO ACCESS BOLTS!
7/16"
4
COMPRESSOR DAMAGE WILL RESULT
remote condensing BIN • TOP-MOUNT
Page 5
Site preparation
1" Stand pipe/Drain
3/4" MPT x 1" slip
3/4" barb x 3/4" FPT
2 ft. x 1" OD
silicone tubing
Minimum 8"
radius
Prepare the installation site.
Provide drainage, water supply and electrical power to within 6 feet (2m) of ice machine in accordance with local and national codes. Outdoor installation is not recommended and will void warranty.
2
2.1
2.1
Installation site requirements
3/8" (9,5mm)
7/8" (22,4 mm)
Electrical ➊
• 120/60/1-5 amps
Potable water supply ➋ (3/8” push-in internal connection, 3/8” OD tubing required)
• 10-70 psi (69-483kpa)
• 45-90 F (7-32 C)
• Follett recommends the use of an in-line water ltration system (item# 00130286)
• This equipment is to be installed with adequate backow protection to comply with applicable federal,
Drain ➌ (3/4” Barb)
• Minimum 8” radius on silicone drain line. Drain line from the ice machine must have at least 1/4” per foot
pitch (6,4mm/0,3m).
Refrigeration lines
• 7/8” (22,4 mm) diameter suction line (insulated)
• 3/8” (9,5 mm) liquid line
BIN • TOP-MOUNT remote condensing
state, and local codes
1'
1/4" per foot (6,4 mm per 0,3 m)
NEMA
5-15
5
Page 6
Prepare the bin.
Bin preparation
3
3.1
• Remove protective tape from
Bin top preparation
gaskets
3.2
Bin top preparation
• Apply gaskets
• Install shuttle actuator and secure with locking nut
through bin top
BEFORE PROCEEDING
Prior to installing the louvered docking assembly, ensure that the drain tting is oriented (right or left) correctly for your installation. An optional straight drain tting is also supplied. You may need to remove the back panel of the docking assembly in order to re-orient or change the drain tting. Replace back panel prior to mounting the docking assembly.
6
remote condensing BIN • TOP-MOUNT
Page 7
Install the louvered docking assembly.
2" (50,8 mm)
Stub Typ
1.81" (46 mm)
3.75" (95.3 mm)
2" (50,8 mm)
Louvered docking assembly
4
2.1
4.1
3/8˝
high pressure
Louvered docking assembly
line
7/8" low pressure line
• Mount louvered docking assembly
• “Rough-in” the refrigerant piping
BIN • TOP-MOUNT remote condensing
7
Page 8
Install the ice transport tube.
5.1
Ice transport tube
Hot Water
160 F (71 C)
5
• Slide insulation onto ice transport tube
• Heat end of transport tube in cup of 160 F (71 C) hot water to soften and spread with pliers
• Connect ice transport tube to coupling on louvered docking station
• Connect ice transport tube to shuttle actuator
before making connection to ease assembly
8
remote condensing BIN • TOP-MOUNT
Page 9
Connect utilities to louvered docking assembly.
External connections
6
6.1
Water and drain
2 ft. x 1" OD
silicone tubing
3/4" barb x 3/4" FPT
3/4" MPT x 1" slip
1" Stand pipe/Drain
Minimum 8"
radius
6.2
Refrigerant lines
• Braze supplied quick-connect lines onto stub-ins
.
• Rough-in ice machine potable water supply 3/8” push-in connection will be made at shut-off valve inside machine
• Remove access panel if necessary
• Connect the silicone tubing to the ice machine 3/4” drain barb
• Assemble the 3/4” barb x 3/4” FPT to the 3/4” MPT x 1” slip. Connect the other end of the silicone tubing to the 3/4” barb
• Connect the 1” slip tting to the 1” stand pipe/drain
Note: Minimum 8” radius on silicone
drain line. Drain line from the ice machine must have at least 1/4” per foot pitch (6,4mm/0,3m).
• Apply Petrol-gel to barbed drain tting
• Replace access panel.
.
➋.
.
.
.
BIN • TOP-MOUNT remote condensing
9
Page 10
Connect louvered docking assembly to ice machine.
Internal connections
7
7. 1
Ice transport tube installation
• Slide ice machine into louvered docking assembly ensuring that drain tube is fully seated on barbed drain tting
• Insert ice transport tube all the way into coupling and tighten nut rmly
7. 2
• Insert potable water line into valve
Water line
7. 3
Refrigeration lines
• Evacuate line set.
• Connect self-sealing liquid and suction line ttings
10
7. 4
• Remove twist tie
• Carefully pass cord thru opening and plug
remote condensing BIN • TOP-MOUNT
Power cord
into wall outlet
Page 11
7. 5
CLEAN
Power cord
7. 6
SERVICE
MAINT/CLEAN
TDS switch
LOW WATER
TIME DELAY
SLEEP CYCLE
MAKING ICE
LOW BIN
POWER ON
TDS
HIGH
LOW
• Position plate into opening and secure with supplied screw
• Set the TDS switch on the electrical box:
HIGH: for extended service life
LOW: for low-scale water
BIN • TOP-MOUNT remote condensing
11
Page 12
Install front cover to ice machine.
Front cover
8
8.1
• Complete installation of condensing unit
• Required rack system capacity at 0 F
1810N: 15,700 Btu/hr (3956 kcal/hr)
2110N: 18,200 Btu/hr (4586 kcal/hr)
Install condensing unit
or connection to rack system.
(-18C) evaporator (EPR supplied by installer).
8.2
• Slide ice machine cover over machine
• Insert and tighten two screws through
Install ice machine front cover
ensuring that tabs on back of cover slip under louvers on back of louvered docking assembly
cover and into louvered docking assembly
NOTICE
Ice machine MUST be sanitized prior to operation!
Consult Operation and Service Manual provided with ice machine for sanitizing instructions.
Horizon, Horizon Elite, Maestro, Harmony, Ice Manager, SafeCLEAN, Sani-Sponge and Vision are trademarks of Follett LLC. Chewblet, RIDE and Follett are registered trademarks of Follett LLC, registered in the US.
801 Church Lane • Easton, PA 18040, USA Toll free (877) 612-5086 • +1 (610) 252-7301 www.follettice.com
01157908R01
© Follet LLC 1/18
Loading...