(See model number congurator on page 2 for details.)
Order parts online
www.follettice.com
self-contained
801 Church Lane • Easton, PA 18040, USA
Toll free (877) 612-5086 • +1 (610) 252-7301
www.follettice.com
01113240R02
Page 2
Chewblet® Ice Machine Model Number Configurations
HC1810DSVA
CondenserSeriesVoltageIcemaker
MC Maestro™
Chewblet
(425 Series)
HC Horizon
Chewblet
(710, 1010,
1410, 1810,
2110 Series)
HM Horizon
Micro Chewblet
C 208-230/60/1 (icemaking head)
®
Self-contained only.
D 115/60/1 (icemaking head)
Self-contained and remote. If remote
unit, high side is 208-230/60/1.
E 230/50/1 (icemaking head)
Self-contained only.
F 115/60/1 (icemaking head)
Remote only. High side is
208-230/60/3.
425 up to
425 lbs
(193 kg)
710 up to
675 lbs
(306 kg)
1010 up to
1061 lbs
(482 kg)
1410 up to
1466 lbs
(665 kg)
1810 up to
1790 lbs
(812 kg)
2110 up to
2039 lbs
(925 kg)
A Air-cooled, self-contained
W Water-cooled, self-contained
R Air-cooled, remote condensing unit
N Air-cooled, no condensing unit for
connection to parallel rack system
V Vision™
H Harmony™
B Ice storage bin
J Drop-in
M Ice Manager
diverter valve
system
P Cornelius Profile
PR150
S RIDE™
T Top-mount
CAUTION!
§ This appliance should be connected by a qualied person in accordance with applicable codes.
§ If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualied persons in order to avoid a hazard.
§ Connect to potable water supply only.
§ This appliance can be used by children aged 8 years and above and persons with reduced physical,
sensory, or mental capabilities, or lack of experience and knowledge if they have been given supervision
or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children
should be supervised to ensure that they do not play with the appliance.
§ This appliance is intended to be used for household and similar applications such as staff kitchen areas
in shops, offices and other working environments; farm houses and by clients in hotels, motels and other
residential type environments; bed and breakfast type environments; catering and similar non-retail
applications.
§ WARNING! To avoid a hazard due to instability of the appliance, it must be xed in accordance with the
instructions.
ConfigurationApplication
(RIDE remote
ice delivery
equipment)
2
self-contained BIN • RIDE Technology
Page 3
Read and complete the following 8 installation steps
Site preparationUnpack
21
Bin preparation
43
Ice transport tube
56
87
Louvered docking assembly
External connection
Front coverInternal connection
BIN • RIDE Technology self-contained
3
Page 4
Carefully unpack and inspect the contents of your Follett ice machine.
Unpack
1
1. 1
Unpack ice machine
➊
➍
➋
7/16"
➌
➎
DO NOT TILT ICE MACHINE
TO ACCESS BOLTS!
7/16"
➏
4
COMPRESSOR DAMAGE
WILL RESULT
➐
self-contained BIN • RIDE Technology
Page 5
Prepare the installation site.
➊
➋
➌
➍
requires 15A circuit,
1.50 mm
2
wire
H_E1410A/W
‡
requires 20A circuit,
4.00 mm
2
wire
2 ft. x 1" OD
silicone tubing
and ttings
provided
1/4" per foot
(6,4 mm per 0,3 m)
H_C1410A/W
H_C1010A/W
NEMA
6-20
NEMA
6-15
H_D710A
NEMA
5-15
H_C1010A/W
*
Provide drainage, water supply and electrical power to within 6 feet (2m)
of ice machine in accordance with local and national codes. Outdoor
installation is not recommended and will void warranty.
• Minimum 8” radius on silicone drain line. Drain line from the ice machine must have at least
1/4” per foot pitch (6,4mm/0,3m).
BIN • RIDE Technology self-contained
(1/4” FPT inlet, 1/4” FPT outlet)
➌
5
Page 6
Prepare the bin
Bin preparation
3
3.1
• Remove protective tape from gaskets
Bin top preparation
3.2
Bin top preparation
➋
➊
➊
• Apply gaskets
• Install shuttle actuator
dispenser top and secure with locking nut
➊
through
➋
➌
➌
6
self-contained BIN • RIDE Technology
Page 7
Install the louvered docking assembly.
BEFORE PROCEEDING
Prior to installing the louvered docking assembly, ensure that the
drain tting is oriented (right or left) correctly for your installation.
An optional straight drain tting is also supplied. You may need to
remove the back panel of the docking assembly in order to re-orient
or change the drain tting. Replace back panel prior to mounting the
docking assembly.
Wall bracket accessoryMachine stand accessory
Louvered docking assembly
4
• Mount louvered docking assembly to wall
bracket accessory
• Mount louvered docking assembly to
machine stand accessory
BIN • RIDE Technology self-contained
7
Page 8
Install the ice transport tube.
Ice transport tube
5
5.1
Ice transport tube installation
➍
➏
➐
➋
Hot Water
160 F (71 C)
➎
➑
➒
➊
1/4˝ (6,4mm)
1' (0,3m)
➌
Ice transport tube tips
• Insulate entire length of ice transport tube
• Secure ice transport tube ➋ as needed to prevent dips and traps from forming. For long tube
runs see guide on page 14.
• Pitch ice transport tube at least 1/4" per foot (6,4mm/.3m)
• Ice transport tube must drain towards ice machine
➊
➌
➓
Ice transport tube to bin
• Be sure tube ends are square
• Heat end of transport tube in cup of 160 F (71 C) hot water to soften and spread with pliers ➎
before making connection to ease assembly
• Push ice transport tube onto ice machine nipple
• Install hose clamp
Ice transport tube to Ice machine
• Be sure tube ends are square
• Heat end of transport tube in cup of 160 F (71 C) hot water to soften and spread with pliers ➎
before making connection to ease assembly
• Push ice transport tube onto ice machine nipple
• Install hose clamp
8
➐
➓
➍
➏
➑
➒
self-contained BIN • RIDE Technology
Page 9
Connect utilities to louvered docking assembly.
External connections
6
6.1
Air-cooled ice machines onlyWater-cooled ice machines only
➊
➋
➌
➏
2 ft. x 1" OD
silicone tubing
3/4" barb x 3/4" FPT
Minimum 8"
radius
➍
3/4" MPT x 1" slip
1" Stand pipe/Drain
➎
• Rough-in ice machine potable water
supply
3/8” push-in connection will be made at
shut-off valve inside machine
• Remove access panel if necessary
• Connect the silicone tubing to the ice
machine 3/4” drain barb
• Assemble the 3/4” barb x 3/4” FPT to the
3/4” MPT x 1” slip. Connect the other end
of the silicone tubing to the 3/4” barb
• Connect the 1” slip tting to the 1” stand
pipe/drain
Note: Minimum 8” radius on silicone
drain line. Drain line from the ice machine
must have at least 1/4” per foot pitch
(6,4mm/0,3m).
• Apply Petrol-gel to barbed drain tting
• Replace access panel.
➊
.
➎
➋.
.
➌
.
➍
.
➏
6.2
➊
➏
• Rough-in ice machine potable water
supply
3/8” push-in connection will be made at
shut-off valve inside machine
• Remove access panel if necessary
• Connect the silicone tubing to the ice
machine 3/4” drain barb
• Assemble the 3/4” barb x 3/4” FPT to the
3/4” MPT x 1” slip. Connect the other end
of the silicone tubing to the 3/4” barb
• Connect the 1” slip tting to the 1” stand
pipe/drain
Note: Minimum 8” radius on silicone
drain line. Drain line from the ice machine
must have at least 1/4” per foot pitch
(6,4mm/0,3m).
• Connect cooling water supply
return
• Apply Petrol-gel to barbed drain tting
• Replace access panel.
➐
➋
➐
➊
.
➎
➌
➑
2 ft. x 1" OD
silicone tubing
3/4" barb x 3/4" FPT
Minimum 8"
radius
➍
3/4" MPT x 1" slip
1" Stand pipe/Drain
➎
➋.
.
➌
.
➍
.
and
➏
➑
BIN • RIDE Technology self-contained
9
Page 10
Connect louvered docking assembly to ice
➊
machine.
CAUTION
• Plug must be accessible after nal installation.
• H_E1410A/W 230/50/1 requires a 20A circuit (4.00 mm
Air-cooled ice machines – follow steps 7.1 through 7.5.
2
wire)
Internal connections
7
7. 1
Ice transport tube
➋
➊
• Slide ice machine into louvered docking
assembly ensuring that drain tube is fully seated on barbed drain tting
• Insert ice transport tube all the way into
coupling and tighten nut rmly
➊
➋
7. 2
• Insert potable water line into valve
Potable water and drain lines
➊
7. 3
• Remove twist tie
• Carefully pass cord thru opening and plug
• For H_E units, install a suitable plug
Power cord
into wall outlet
10
7. 4
• Position plate into opening and secure
self-contained BIN • RIDE Technology
Power cord
with supplied screw
Page 11
Water-cooled ice machines – follow steps 7.6 through 7.12.
In
Out
CLEAN
7. 5
SERVICE
Set TDS switch
MAINT/CLEAN
LOW WATER
TIME DELAY
SLEEP CYCLE
MAKING ICE
LOW BIN
POWER ON
TDS
HIGH
LOW
• Set the TDS switch on the electrical box:
HIGH: for extended service life
LOW: for low-scale water
7. 6
Cooling lines
• Install ice machine cooling water lines to
louvered docking assembly
7. 7
Ice transport tube
➋
➊
• Slide ice machine into louvered docking
assembly ensuring that drain tube is fully seated on barbed drain tting
• Insert ice transport tube into coupling and
tighten nut rmly
➋
➊
7. 8
Potable water and drain lines
➊
• Insert potable water line into valve
➊
BIN • RIDE Technology self-contained
11
Page 12
7. 9
CLEAN
Cooling lines and power
➋
➊
• Connect cooling water lines to ice
machine
• Water valve is set at the factory. DO NOT
remove seal or adjust water valve
➊
➋
7. 1 0
Power cord
• Remove twist tie
• Carefully pass cord thru opening and plug
into wall outlet
• For H_E units, install a suitable plug
7. 11
Power cord
• Position plate into opening and secure
with supplied screw
7. 1 2
SERVICE
TDS switch
MAINT/CLEAN
LOW WATER
TIME DELAY
SLEEP CYCLE
MAKING ICE
LOW BIN
POWER ON
TDS
HIGH
LOW
• Set the TDS switch on the electrical box:
HIGH: for extended service life
LOW: for low-scale water
12
self-contained BIN • RIDE Technology
Page 13
Install front cover to ice machine.
Front cover
8
Front cover installation –
air-cooled undercounter only
➊
➋
➌
CAUTION
• Keep ventilation openings in the appliance enclosure
clear of obstruction.
• To ensure proper ventilation (if not using supplied grille)
carefully review air circulation specications in section
4.1
Install front cover
➋
➌
• Slide ice machine cover over machine
ensuring that tabs on back of cover
slip under louvers on back of louvered
docking assembly
• Insert and tighten two screws through
cover and into louvered docking assembly
➊
➊
➋
• For air-cooled machines only, install
plastic grill
➌
• Remove and discard plastic grille
• Apply supplied gasket material around
entire opening on skin to prevent air
recirculation
• Attach supplied metal grille to opening in
counter door (see section 4.1)
➋
Ice machine MUST be sanitized prior to operation!
Consult Operation and Service Manual provided with ice machine for sanitizing instructions.
➊
➌
BIN • RIDE Technology self-contained
NOTICE
13
Page 14
Long tube run recommendations
max. 2 ft (0,6m)
➋
1/4" (6,4mm)
➊
1' (0,3m)
• Pitch ice transport tube to allow melt water to drain towards ice machine
• Secure insulated ice transport tube at least every 2 ft (0,6m) to prevent dips or traps
➊
➋
14
self-contained BIN • RIDE Technology
Page 15
BIN • RIDE Technology self-contained
15
Page 16
Horizon, Horizon Elite, Maestro, Harmony, Ice Manager, SafeCLEAN, Sani-Sponge, RIDE and Vision are trademarks of Follett LLC.
Chewblet is a registered trademark of Follett LLC, registered in the US.
801 Church Lane • Easton, PA 18040, USA
Toll free (877) 612-5086 • +1 (610) 252-7301
www.follettice.com