Follett HCC1010AVS, HCC1410WVS, HCD710AVS, HCD1010NVS, HCF1010RVS Installation Manual

...
Horizon Elite™ Ice Machine Models with RIDE™ Technology
Installation Instructions for Vision
(See model number congurator on page 2 for details.)
Order parts online www.follettice.com
self-contained
801 Church Lane • Easton, PA 18040, USA Toll free (877) 612-5086 • +1 (610) 252-7301 www.follettice.com
01113208R02
Chewblet® Ice Machine Model Number Configurations
HC 1810D SVA
ConfigurationApplication
S RIDE™
(RIDE remote ice delivery equipment)
T Top-mount
MC Maestro™
Chewblet (425 Series)
HC Horizon
Chewblet (710, 1010, 1410, 1810, 2110 Series)
HM Horizon
Micro Chewblet
C 208-230/60/1 (icemaking head)
®
Self-contained only.
D 115/60/1 (icemaking head)
Self-contained and remote. If remote unit, high side is 208-230/60/1.
E 230/50/1 (icemaking head)
Self-contained only.
F 115/60/1 (icemaking head)
Remote only. High side is 208-230/60/3.
425 up to
425 lbs (193 kg)
710 up to
675 lbs (306 kg)
1010 up to
1061 lbs (482 kg)
1410 up to
1466 lbs (665 kg)
1810 up to
1790 lbs (812 kg)
2110 up to
2039 lbs (925 kg)
CondenserSeriesVoltageIcemaker
A Air-cooled, self-contained W Water-cooled, self-contained R Air-cooled, remote condensing unit N Air-cooled, no condensing unit for
connection to parallel rack system
V Vision™ H Harmony™ B Ice storage bin J Drop-in M Ice Manager
diverter valve system
P Cornelius Profile
PR150
CAUTION!
• This appliance should be connected by a qualied person in accordance with applicable codes.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualied persons in order to avoid a hazard.
• Connect to potable water supply only.
• This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children should be supervised to ensure that they do not play with the appliance.
• This appliance is intended to be used for household and similar applications such as staff kitchen areas in shops, offices and other working environments; farm houses and by clients in hotels, motels and other residential type environments; bed and breakfast type environments; catering and similar non-retail applications.
• WARNING! To avoid a hazard due to instability of the appliance, it must be xed in accordance with the instructions.
2
self-contained VISION • RIDE Technology
Read and complete the following 8 installation steps
Unpack
1
Dispenser preparation
3
Ice transport tube
5
Site preparation
2
Louvered docking assembly
4
External connection
6
Internal connection
7
Front cover
8
VISION • RIDE Technology self-contained
3
Carefully unpack and inspect the contents of your Follett ice machine.
Unpack
1
1. 1
Unpack ice machine
7/16"
DO NOT TILT ICE MACHINE TO ACCESS BOLTS!
7/16"
4
COMPRESSOR DAMAGE WILL RESULT
self-contained VISION • RIDE Technology
1" PVC Drain
2 ft. x 1" OD
silicone tubing
3/4" MPT x 1" slip
3/4" barb x 3/4" FPT
1'
1/4" per foot
(6,4 mm per 0,3 m)
Site preparation
Prepare the installation site.
Provide drainage, water supply and electrical power to within 6 feet (2m) of ice machine in accordance with local and national codes. Outdoor installation is not recommended and will void warranty.
2
2.1
2.1
Installation site requirements
H_C1010A/W
NEMA
6-15
H_D710A
NEMA
5-15
H_C1410A/W
requires 15 amp circuit
requires 20 amp circuit
NEMA
6-20
H_E1010A/W
2
1.50 mm
H_E1410A/W
4.00 mm
wire
2
wire
VISION • RIDE Technology self-contained
Electrical ➊
• H_C1010/1410 (A/W)VS 208-230/60 • H_D710AVS 115/60
• H_E10101410 (A/W)VS 230/50
(H_E1010A/W requires 15A dedicated circuit 1.50 mm2 wire, H_E1410A/W requires 20A dedicated circuit 4.00 mm2 wire)
‡ Plug must be provided by end user & must conform to standard EN 60 335-2-24 of the end destination.
Requires dedicated 15A circuit.
Potable water supply ➋ (3/8" push-in internal connection, 3/8" OD tubing required)
• 10-70 psi (69-483kpa)
• 45 to 90 F (7 to 32 C)
• Follett recommends the use of an in-line water ltration system (item# 00130286)
• This equipment is to be installed with adequate backow protection to comply with applicable federal, state, and local codes
Condenser water supply for water-cooled systems
(1/4" FPT inlet, 1/4" FPT outlet)
• 10 psi min.; 150 psi max. (69kpa min.; 1034kpa max.)
• 45 to 90 F (7 to 32 C)
• 1.5 gallons per minute (5.68 liters per minute)
Drain
(3/4” Barb)
• Minimum 8” radius on silicone drain line. Drain line from the ice machine must have at least 1/4” per foot pitch (6,4mm/0,3m).
5