Welcome to Follett
Follett equipment enjoys a well-deserved reputation for excellent performance, long-term reliability and
outstanding after-the-sale support. To ensure that this product delivers that same degree of service, we ask that
you take a moment to review this manual before beginning the installation. Should you have any questions or
require technical help at any point, please call our technical service group at (800) 523-9361 or (610) 252-7301.
Before you begin
After uncrating and removing all packing material, inspect the equipment for concealed shipping damage.
If damage is found, notify the shipper immediately and contact Follett Corporation so that we can help in the
ling of a claim, if necessary.
Speci cations
Series speci cations
FZR5
34.00" height for freestanding use or installation below standard 36" (915mm) high counter
4.0 cu ft (usable cubic volume)
FZR4-ADA
31.25" height for freestanding use or installation below 34" (864mm) high ADA-compatible counter
3.3 cu ft (usable cubic volume)
Electrical speci cations
115V, 60Hz, 1 phase
Full load amps: 8.0
Minimum circuit ampacity: 15 amp
Maximum size of branch circuit overcurrent device: 15 amp
Refrigeration speci cations
Refrigerant – R404A
Charge size – 10 oz
Maximum design pressures:
High side – 383psi
Low side – 175psi
Installation speci cations
Ambient temperature must not exceed 100 F (38 C).
The front louvered panel must be kept free of any cabinet trim or obstructions to ensure proper ventilation of the
refrigeration system.
Important cautions
• Equipment must be wired according to local and NEC codes.
• Always disconnect power before servicing freezer.
3
Installation
2
1
3
Installing legs – required
1. Remove legs from plastic bag packed inside freezer.
2. Tip freezer back and screw legs in all the way to stop (they will extend
1/8" below base of freezer).
3. Adjust legs as needed to level freezer in both directions. To access
legs, remove the lower front panel. Turn legs clockwise to extend legs.
Fig. 1
Installing shelves – required
1. Remove shelves and shelf brackets packed inside freezer.
2. Install shelf brackets in pilasters (insert top tab, squeeze and push in
lower tab).
Installing controller faceplate – required
The freezer is shipped from the factory con gured to display in
degrees C. If degrees F display is desired, resetting of temperature
controller is required.
1. Remove degrees F and degrees C faceplates from plastic bag
packed inside refrigerator.
2. Snap appropriate faceplate in place over controller face.
Fig. 2
Fig. 3
Changing temperature controller settings – optional
Follett’s temperature controller is pre-programmed with a -25 C (-13 F)
set point and degrees C display. The -25 C (-13 F) set point delivers a
temperature range of -23 to -25 C (-9 to -13 F). Follett’s controller set point
can be changed to deliver up to a -15 C (+5 F) temperature for applications
where a lower temperature is not desired (i.e. ice cream). See page 6 to
change controller settings.
4
Fig. 4
Reversing the door swing – optional
1
2
1
1
2
NOTICE
When reinstalling latch and hinge screws, 242 blue Loctite* MUST be
applied to screws. Torque screws to 25 in-lbs.
1. Remove screws and latch from refrigerator cabinet (Fig. 5.1).
2. Use at screwdriver to carefully remove (do not scratch) hinge
covers (Fig. 6.1).
Fig. 5
3. Support door and remove screws attaching hinge to refrigerator
cabinet (Fig. 6.2).
4. Cover hinge screw holes with screw hole plugs removed from
opposite side.
5. Reverse door. Apply 242 blue Loctite to hinge screws and reinstall
torqued to 25 in-lbs.
6. Reinstall latch on opposite side.
7. Remove screws and handle from door (Fig. 7.1).
8. Rotate handle (Fig. 7.2).
9. Apply 242 blue Loctite to latch screws and reinstall torqued to 25 in-lbs.
1
2
Fig. 6
Fig. 7
Loctite is a registered trademark of Henkel Corporation in the United States and other countries.
5
Controller operation
In normal operation the controller displays cabinet temperatures
in degrees C (default) or user-selected degrees F. Degrees C
temperatures are displayed to 1 decimal point.
Rocker buttons to the right of the temperature display control all
programming functions.
The controller is pre-programmed with a -25 C (-13 F) set point
which provides a compressor cut-in at -23 C (-9 F) and cut-out at
-25 C (-13 F). The controller set point can be raised to -15 C (+5 F)
for nourishment applications where a lower temperature is not
desired (i.e. ice cream). Follow instructions for changing temperature
cut-out below.
All set points have a 2 C differential. The 2 C differential means that with a -25 C set point, for example, the
compressor will turn off at -25 C (-13 F) and turn on when it reaches -23 C (-9 F).
Fig. 8
evaporator
fan
energized
defrost
- 25
not used
refrigeration
system
energized
prg
SET
°C
To display temperature cut-out
STEP INPUT DISPLAY
1 Press and release SET Current cut-out temperature will display for approximately 5 seconds.
Display will return to current refrigerator temperature.
To change temperature cut-out
STEP INPUT DISPLAY
1 Press and hold SET for Current cut-out temperature displayed, refrigeration system
3 seconds energized LED ashes
2 Press UP or DOWN arrows to New cut-out temperature displayed
desired cut-out temperature
3 Press and release SET New cut-out temperature blinks three times, then current refrigerator
temperature will display
To change temperature display from degrees C to degrees F
Follett includes a programming key (part# 00155630) that changes the display and temperature settings from
degrees C to degrees F.
Programming freezer from a degree F key (download)
1. Turn OFF freezer.
2. Remove 6 screws from panel holding controller to access back of controller.
3. Insert degree F programmed key into 5 PIN receptacle on controller back.
4. TURN ON freezer.
5. Values from key automatically download to freezer (“dol” message blinks followed by “end”).
6. After 10 seconds display returns to current freezer temperature and controller will restart with new values.
7. Remove key.
8. Freezer will now display in degrees F.
Note: An “Err” message displays for failed programming. Turn freezer OFF then ON to restart download, or
remove key to abort.