Folger Adam 310-4-1-12D-605, 310-4-1-12D-605-LCBMA, 310-4-1-12D-606, 310-4-1-12D-606-LCBMA, 310-4-1-12D-612 Installation Instructions

...
0 (0)
Folger Adam 310-4-1-12D-605, 310-4-1-12D-605-LCBMA, 310-4-1-12D-606, 310-4-1-12D-606-LCBMA, 310-4-1-12D-612 Installation Instructions

Installation Instructions

Folger Adam 310-4-1, -2, -3, -30 Series Electric Strike

HES, Inc.

22630 N. 17th Ave.

Phoenix, AZ 85027 800-626-7590 www.hesinnovations.com

1

Product Components

1

Electric Strike Body & Faceplate

3

#14 x 2” Mounting Screws

2

1/4-20 x 1” Mounting Screws

4

Plug In Connectors*

*Only 1 Plug In Connector is used with 310-4-30

1

2

3

4

Electrical Specifications

ELECTRICAL RATINGS FOR SOLENOID*

CONTINUOUS DUTY

12VDC

24VDC

Resistance in Ohms

23.5

96

Amps

.51

.25

Solenoids are rated at +/- 10% indicated value. *Resistance value indicated above is per coil.

MINIMUM WIRE GAUGE REQUIREMENTS

SOLENOID VOLTAGE

12VDC

24VDC

200 feet or less

18 gauge

18 gauge

200 - 300 feet

16 gauge

18 gauge

300 - 400 feet

14 gauge

16 gauge

 

 

 

 

Installation Directions

 

 

2

 

 

 

 

 

 

 

CAUTION! Before connecting any device at the installation site, verify input voltage using a multimeter.

Many power supplies and low voltage transformers operate at higher levels than listed. Any input voltage exceeding 10% of the solenoid rating may cause severe damage to the unit and will void the warranty.

Prepare Strike

1.If using the LCBMA (Latchbolt Monitor & Locking Cam Monitor), see Diagram 1 for wiring instructions.

2.The strike body ships as either a 12 or 24 volt

unit and is not field selectable. Verify the available voltage is +/- 10% of the rated voltage of the strike body.

Prepare Frame

3.Prepare frame using the template for your strike located on pages 3-4.

Finish Installing

4.Connect the Plug In Connector to the electric strike, and connect wires from the Plug In Connector leads to the power source.

5.Install the electric strike unit in jamb cutout, using the 1/4-20 x 1” mounting screws for metal applications, or the #14 x 2” screws for wood applications.

Diagram 1: Monitoring Switches

Latchbolt Monitor (LBM)

 

White

Common

White

Orange

Normally Open

Green

Normally Closed

Orange

 

 

Green

Locking Cam Monitor (LCM)

 

Brown

Common

Brown

Blue

Normally Open

Yellow

Normally Closed

Blue

 

 

Yellow