FMI UV32C, NLUV32C, RUV32, NLRUV32 Owner's Operation And Installation Manual

UNVENTED (VENT-FREE)
32" UNIVERSAL FIREBOX
OWNER’S OPERATION AND INSTALLATION MANUAL
UV32C (shown)
and NLUV32C
Circulating
Louvered;
RUV32 and
NLRUV32
Noncirculating
Smooth Face
Models
®
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a
qualified installer, service agency, or the gas supplier.
This firebox may be installed in an aftermarket* manufactured (mobile) home, where not prohib­ited by state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer (i.e. Installation of this product is permitted after the manufactured (mobile) home is sited).
WARNING: Improper installa­tion, adjustment, alteration, ser­vice, or maintenance can cause injury or property damage. Re­fer to this manual for correct installation and operational pro­cedures. For assistance or addi­tional information consult a quali­fied installer, service agency, or the gas supplier.
WARNING: For use only with decorative type unvented room heaters. Do not build a wood fire.
This firebox has been tested and approved by I.A.S. under their REQ. 2-97 for use with any ANS Z21.11.2 approved gas logs.
Save this manual for future reference.
FIREPLACE MANUFACTURERS INC. UNVENTED 32" FIREBOX
SAFETY INFORMATION
WARNINGS
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper­ate, or service this firebox. Im­proper use of this firebox can cause serious injury or death from burns, fire, explosion, electrical shock, or carbon monoxide poisoning.
CAUTION: Carefully review the instructions supplied with the decorative type unvented room heater for the minimum fireplace size requirement. Do not install the appliance in this firebox, unless this firebox meets the minimum dimensions required for the installation.
WARNING: Any change to this firebox or its controls can be dangerous.
1. This firebox shall not be installed in a bedroom or bathroom.
2. Never install the firebox
• in a recreational vehicle
• where curtains, furniture, clothing, or
other flammable objects are less than 42 inches from the front, top, or sides of the firebox
• in high traffic areas
• in windy or drafty areas
3. Do not use this firebox as a wood-burn­ing fireplace. Use only decorative unvented room heaters (log sets).
4. Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting.
5. Y ou must operate this fireplace with the fireplace screen, hood, and brick liner in place. Make sure these parts are in place and screens are closed before run­ning firebox.
6. Do not allow fans to blow directly into the firebox. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.
7. Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater. Do not use blower accessory with Models RUV 32 and NLRUV32. Use only the provided hood or GA6096 polished brass hood accessory (see Accessory on page 11).
8. Vent-free gas log heaters installed in these fireboxes require fresh air venti­lation to run properly . See Air for Com- bustion and Ventilation, pages 4 through 6.
9. Do not run firebox
• where flammable liquids or vapors
are used or stored
• under dusty conditions
10. Do not use this firebox to cook food or burn paper or other objects.
11. Never place any objects in the firebox or on logs.
12. Firebox front and screen becomes very hot when running firebox. Keep chil­dren and adults away from hot surfaces to avoid burns or clothing ignition. Fire­box will remain hot for a time after shut-down. Allow surfaces to cool be­fore touching.
13. Carefully supervise young children when they are in the room with fire­box.
14. Turn firebo x off and let cool before ser­vicing. Only a qualified service person should service and repair firebox.
15. Operating vent-free log sets in a fire­box above elevations of 4,500 feet could cause pilot outage.
16. Do not use the firebox if it has been under water due to the shock hazard that could result with the blower accessary (if installed) in place.
LOCAL CODES
Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1, also known as NFPA 54*. Firebox must be electrically grounded in accordance with the National Electrical Code, ANS/NFPA70 (latest edition).
*Available from: American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
UNPACKING
1. With utility knife, cut the carton all the way around above the staples on the bottom tray. Lift the car ton off the fire­box. Remove packing. is located in the packing on the right hand side of the heater front. Lift the heater off the bottom tray.
2. Check carton contents for the following:
• Screen assembly (2)
• Screen support rod (2)
• Hood
• Hardware and parts bag containing
the following:
- Owner’s Operation and Installation Manual
- 2 - Black #10 x 3/8" Phillips screws
- 3 - Zinc #10 x 1/2" shouldered hex screws
- 2 - Black #10 x 5/8" shouldered hex screws
If any items are missing, inform dealer where you bought firebox.
3. Check all items for any shipping dam­age. If damaged, promptly inform dealer where you bought firebox.
Note:
The hood
2
105509
PRODUCT SPECIFICATIONS
Standoffs (Models RUV32 and NLRUV32 only)
35 1/16"
OWNER’S MANUAL
3
2
/4"
Built-in Nailing Flanges
Louvers (Models UV32C and NLUV32C only)
Figure 1 - Firebox Front View
Standoffs (Models RUV32 and NLRUV32 only)
3
/4"
2
33
1
1
/2"
6"
11
/16"
3
/16"
32
19
3
/8"
3
/4"
31
19
1
16
/4"
3
/4"
2
3
/8"
6
22 1/2"
11
16
/16"
1
/4"
12 1/2"
3
9
/4"
5
4
/8"
Electrical Access Hole
Electrical Access Hole with Bushing
Figure 2 - Firebox Side View
105509
1
2
/2"
Gas Line Access
Figure 3 - Firebox Top View
3
31 34 3/8" 35 5/8"
5
/8"
FIREPLACE MANUFACTURERS INC. UNVENTED 32" FIREBOX
PRODUCT FEATURES
OPERATION
This firebox is designed for use with ap­proved ANS Z21.1.2 decorative type unvented room heaters. (Physical size limi­tations apply. Refer to minimum firebox requirements supplied with log heater.) It requires no outside venting or chimney mak­ing installation easy and inexpensive. When used without the blower (models UV32C and NLUV32C only), the firebox requires no electricity making it ideal for emergency back-up heat.
BLOWER ACCESSORY
The UV32C and NLUV32C fireboxes will accept the FA3700 accessory. The variable blower allows you to select the fan speed you desire. The blower circulates heated air from the firebox into the room. Use of blower is optional.
LOCATING FIREBOX
PLANNING
Plan where you will install the firebox. This will save time and money later when you install the firebox. Before installation, con­sider the following:
1. Where the firebox will be located. Al­low for wall and ceiling clearances (see Installation Clearances, page 7).
2. Everything needed to complete instal­lation.
3. These models CANNOT be installed in a bedroom or bathroom.
4. Proper air for combustion and ventila­tion (see below).
AIR FOR COMBUSTION AND VENTILATION
WARNING: This firebox shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ven­tilation air. Read the following in­structions to insure proper fresh air for this and other fuel-burning appliances in your home.
Today’s homes are built more energy effi­cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com­bustion and ventilation.
Exhaust fans, fireboxes, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad­equate fresh air for these appliances. This will insure proper venting of vented fuel­burning appliances.
PROVIDING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec­tion 5.3, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three following ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space The information on pages 4 through 6 will
help you classify your space and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and win­dows may provide enough fresh air for combustion and ventilation. However, in
buildings of unusually tight construction, you must provide additional fresh air.
Unusually tight construction is de­fined as construction where:
a. walls and ceilings exposed to the
outside atmosphere have a con­tinuous water vapor retarder with a rating of one perm (6x10 per pa-sec-m2) or less with open­ings gasketed or sealed
b. weather stripping has been
added on openable windows and doors
c. caulking or sealants are applied
to areas such as joints around window and door frames, be­tween sole plates and floors, be­tween wall-ceiling joints, be­tween wall panels, at penetra­tions for plumbing, electrical, and gas lines, and at other openings.
If your home meets all of the three criteria above, you must provide additional fresh air. See
Air From Outdoors,
If your home does not meet all of the three criteria above, proceed to
mining Fresh-Air Flow For Firebox Location
, page 5.
and
page 6.
-11
kg
and
Ventilation
Deter-
Confined Space and Unconfined Space
The National Fuel Gas Code (ANS Z2123.1, 1992 Section 5.3) defines a confined space
as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are in­stalled*, through openings not furnished with doors, are considered a part of the unconfined space.
This heater shall not be installed in a con­fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.
* Adjoining rooms are communicating only if there are doorless passageways or ventila­tion grills between them.
4
105509
OWNER’S MANUAL
AIR FOR COMBUSTION AND VENTILATION
Continued
DETERMINING FRESH-AIR FLOW FOR FIREBOX LOCATION
Determining if You Have a Confined or Unconfined Space
Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install firebox plus any adjoining rooms with doorless passageways or ventilation grills
between the rooms.
1. Determine the volume of the space (length x width x height). Length x Width x Height = _________ cu. ft. (volume of space)
Example
If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total vol ume of the space.
2. Divide the space volume by 50 cubic feet to determine the maximum Btu/Hr the space can support.
__________ (volume of space) ÷ 50 cu. ft. = (Maximum Btu/Hr the space can support)
Example:
3. Add the Btu/Hr of all fuel burning appliances in the space. Gas water heater* _____________________ Btu/Hr Gas furnace _____________________ Btu/Hr Vented gas heater _____________________ Btu/Hr Gas firebox logs _____________________ Btu/Hr Other gas appliances*+ _____________________ Btu/Hr Total = _____________________ Btu/Hr * Do not include direct-vent gas appliances. Direct-vent draws combustion air from the outdoors and vents to the outdoors.
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.
_____________________Btu/Hr (maximum the space can support) _____________________Btu/Hr (actual amount of Btu/Hr used)
Example:
The space in the above example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an adjoining room. If the extra space pr ovides an unconfined space, remov e door to adjoining
room or add ventilation grills between rooms. See Ventilation Air from Inside Building, page 6.
B. Vent room directly to the outdoors. See Ventilation Air from Outdoors, page 6. C. Install a lower Btu/Hr firebox, if lower Btu/Hr size makes room unconfined. If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no
additional fresh air ventilation.
: Space size22 ft. (length) x 18 ft. (width) x 8 ft. (ceiling height) = 3168 cu. ft. (volume of space)
3168 cu. ft. (volume of space) ÷ 50 cu. ft. = 63.3 or 63,300 (maximum Btu/Hr the space can support)
Example:
Gas water heater 40,000 Btu/Hr Vent-free firebox
with log heater + 39,000 Btu/Hr Total = 79,000 Btu/Hr
63,300 Btu/Hr (maximum the space can support) 79,000 Btu/Hr (actual amount of Btu/Hr used)
WARNING: If the area in which the firebox and gas log heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the applicable local codes.
105509
National Fuel Gas Code, ANS Z223.1, 1992, Section 5.3
Continued
5
or
FIREPLACE MANUFACTURERS INC.
,
,
,
,
,
,
UNVENTED 32" FIREBOX
AIR FOR COMBUSTION AND VENTILATION
Continued
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro­vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 4). You can also remove door into adjoining room (see op­tion 3, Figure 4). Follow the National Fuel
Gas Code NFPA 54/ANS Z223.1, Section
5.3, Air for Combustion and Ventilation for
required size of ventilation grills or ducts.
WARNING: Rework work­sheet, adding the space of the
adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two per­manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.
IMPORTANT:
inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.
Do not provide openings for
Ventilation
Grills
Into Adjoining
Room,
Option 1
Or
Remove
Door into
Ventilation Grills
Into Adjoining Room,
Adjoining
Room, Option
3
12"
Figure 4 - Ventilation Air from Inside Building
Outlet Air
Ventilated Attic
Outlet Air
Inlet Air
Inlet Air
12"
Option 2
To Attic
To
Crawl
Space
Ventilated
Crawl Space
Figure 5 - Ventilation Air from Outdoors
6
105509
42"
16"
Face or Cabinet Mantel
Corner Mantel
12"
Floor - 0"
INSTALLATION
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri­mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
OWNER’S MANUAL
Note
: Your Vanguard firebox is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the rear, sides, or top of your firebox, except where stand-off spacers are integrally attached. If stand-off spacers are attached to your fire­box, these spacers can be placed directly against wall or framing materials.
Use the dimensions shown for rough open­ings to create the easiest installation (see Built-In Fireplace Installation, page 10).
INSTALLATION CLEARANCES
Clearances for Cabinet or Corner Mantel Installation
Note:
Clearances are the same if using cabinet mantel or built-in installation.
MINIMUM CLEARANCE
NOTICE: A qualified service per­son must install firebox. Follow all local codes.
WARNING: Never install the
firebox
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the firebox
• in high traffic areas
• in windy or drafty areas
CAUTION: Log heaters in­stalled in this firebox create warm air currents. These currents move heat to wall surfaces next to fire­box. Installing firebox next to vi­nyl or cloth wall coverings or op­erating firebox where impurities (such as tobacco smoke, aro­matic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls.
WARNING: Maintain the mini­mum clearances. If you can, pro­vide greater clearances from floor, ceiling, and adjoining wall.
Carefully follow the instructions below. This will ensure safe installation.
Minimum Wall and Ceiling Clearances (see Figure 6)
A. Clearances from the side of the firebox
opening to any combustible wall should not be less than 16 inches for a cabinet mantel or 12 inches for a corner instal­lation.
B. Clearances from the top of the firebox
opening to the ceiling should not be less than 42 inches.
C. When the firebox is installed directly
on carpeting or other combustible ma­terial, other than wood flooring, the firebox should be installed on a metal or wood panel extending the full width and depth of the enclosure.
Figure 6 - Minimum Clearance to Wall and Ceiling
Mantel Clearances for Built-In Installation
If placing custom mantel above built-in firebox, you must meet the minimum allow­able clearance between mantel shelf and top of firebox opening shown in Figure 7 on page 8. These are the minimum allowable mantel clearances for a safe installation. Use larger clearances wherever possible to minimize the heating of objects and materi­als placed on the mantel.
CAUTION: Do not allow the vent-free gas log heater to touch or extend beyond the fireplace screen.
If your installation does not meet the mini­mum clearances in Figure 7 on page 8, you must:
• raise the mantel to an acceptable height, OR
• remove the mantel.
IMPORTANT:
Vent-free gas log heaters add moisture to the air. Although this is beneficial, installing firebox in rooms with­out enough ventilation air may cause mil­dew to form from too much moisture. See Air for Combustion and Ventilation, pages 4 through 6.
IMPORTANT:
level. If firebox is not level, log set will not work properly.
105509
Make sure the firebox is
Continued
7
FIREPLACE MANUFACTURERS INC. UNVENTED 32" FIREBOX
INSTALLATION
INSTALLATION
Continued
Continued
Note
: All vertical measurements are from top of fireplace opening to bottom of mantel shelf. All measurements are in inches.
Facing material (above firebox) may be of combustible material, including decorative mantel ornaments.
Firebox
Wire-mesh Screen
Mantel Shelf 10" 8" 6"
1
2
"
/2
18.5" 20" 21" 22"
13" 16" 19" 21"
Supplied Firebox Hood Must Be Used at All Times
For RUV32 and NLRUV32 Series noncirculating smooth face models
For UV32C and NLUV32C Series circulating louvered models only
2. Place the blower against lower rear wall of firebox wrapper with the exhaust port directed upward. Align the holes in top mounting tabs of blower with holes in wall of wrapper (see Figure 9). Using 2 screws provided, mount blow er and tighten screws securely.
3. Be certain that all wire terminals are securely attached to terminals on blower motor and that the screw retain­ing the green ground wire is tight.
4. Locate the plastic hole plug installed in the 3/8" diameter opening in the lower right side of the firebox front panel (see Figure 9). Remove the plas­tic plug and discard.
5. Place speed control against inner wall of front panel, pushing the plastic con­trol shaft forward through the opening (see Figure 10, page 9).
6. While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clock­wise until it is tight against front panel. Place control knob provided on shaft (see Figure 10, page 9).
Figure 7 - Minimum Mantel Clearances for Built-In Installation
Figure 7 - Minimum Mantel Clearances for Built-In Installation
INSTALLING BLOWER ACCESSORY (Models UV32C and NLUV32C only)
You may install blower accessory FA3700 with a cabinet mantel installation or with built-in installation (page 10) with models UV32C and NLUV32C only.
WARNING: If there is a duplex electrical outlet installed in the right side of the bottom of the fireplace base area, be sure that the electrical power to the outlet is turned off before proceeding with blower installation. Failure to do this may result in serious injury.
Conventional Installation of Blower Accessory
NOTICE: If a log set is currently installed in the firebox, discon­nect log set from gas supply and remove from firebox. Contact a qualified service person to do this.
1. Remove the firebox bottom: a. Remove the 4 screws that secure the
bottom of the firebox (see Figure 8).
b.Carefully raise and remove the fire-
box bottom from the firebox.
Figure 8 - Removing Screws from Firebox Bottom
Screws
Lower Rear Wall of Firebox Wrapper
Blower
Screws
Floor Supports
Plastic Hole Plug
Exhaust Port
Top Mounting Tab
Figure 9 - Mounting Blower to Firebox
8
105509
OWNER’S MANUAL
INSTALLATION
Continued
7. Plug in blower power cord. a. If your firebox is installed as a free-
standing unit, determine whether the power cord will exit the left side or the right side of the firebox. Install 1 plas­tic bushing provided into the 1 1/2" hole in the floor support on the exit side. Install the second plastic bushing pro­vided into the 11/2" hole in the outer casing through which the power cord will exit (see Figure 11). Route power cord through both plastic bushings and plug the power cord into a 3-prong grounded wall receptacle near the firebox.
b. If your firebox installation is re-
cessed and/or pre-wired, see Built- In Installation of Blower Accessory,
column 2.
8. Turn on power to duplex outlet if previ­ously turned off per the warning in step 1.
9. Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign ob­jects in blower wheel. Turn blower on and check for operation.
WARNING: Never touch the
blower wheel while in operation.
10. Peel off the backing paper and stick the supplied wiring diagram decal on the fire­box bottom approximately 12" in front of the blower .
11. Replace bottom of firebox. sure the back of the firebox bottom slides under the rear of the firebrick (lift the firebrick up if necessary.)
12. Reattach firebox bottom using 4 screws removed in step 1.
Note:
Discard the remaining hardw are
items.
13. Install the log set heater according to the installation instructions supplied with the heater.
NOTICE: A qualified electrician must connect electrical wiring to duplex outlet for built-in installa­tion. Follow all local codes. In absence of local codes follow
National Electrical Code ANS/ NFPA 70.
Note:
Make
The
Speed Control
Control Knob
Figure 10 - Attaching Speed Control
Figure 11 - Installing Plastic Bushing for Power Cord
Control Shaft
Lock Nut
Plastic Bushing
Built-In Installation of Blower Accessory
1. Before replacing bottom of firebox, remove screw holding duple x outlet to the support bracket in the bottom of firebox. Remove duplex outlet.
2. Clamp electrical cable into firebox through smallest hole in outer casing using strain relief provided.
3. Route wires from electrical box through hole in side of heater and hole in sup­port bracket (see Figure 12).
4. Connect wires from the electrical box to duplex outlet. Match wire colors to those indicated on duplex outlet. Be sure to connect ground wire.
5. Replace duplex outlet with screw.
6. Plug blower power cord into duplex outlet.
7. Replace bottom of firebox.
Support
Blower
Figure 12 - Routing Blower Accessory Power Cord for Built-In Installation
Bracket
Blower Power Cord
Cables From Electrical Source
Duplex Outlet
Screw
Operating the Blower
Light your gas appliance with the blower off. After about 15 minutes, turn the blower on to deliver heated air at the top louvers. The blower features a variable control which allows you to select the speed you desire.
Note:
Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions.
INSTALLING LOG HEATER IN FIREBOX
CAUTION: Do not remove the
metal data plates attached to the heater base assembly. The data plates contain important war­ranty information.
CAUTION: Do not pick up log
base assembly by burners. This could damage burners. Only handle base by grates.
1. Remove four screws holding firebox
bottom in place.
2. Lift and remove firebox bottom (see
Figure 13, page 10).
3. If installing FA3700 Blower Accessory
(Models UV32C and NLUV32C only), see Installing Blower Accessory, page 8.
4. Route flexible gas line from manual
shutoff valve into f irebox through side.
NOTICE: Most building codes do not permit concealed gas con­nections. A flexible gas line is recommended to allow accessi­bility from the firebox. The flex­ible gas supply line connection to the manual shutoff valve should be accessible.
5. Install and properly test gas log heater .
Follow installation instructions in­cluded with the vent-free gas log heater that is being installed.
6. Replace firebox bottom and secure with
screws.
Continued
Continued
105509
9
FIREPLACE MANUFACTURERS INC.
34 3/4"
17 3/4"
33" (UV32C and
NLUV32C)
34 1/4" (RUV32 and
NLRUV32)
UNVENTED 32" FIREBOX
INSTALLATION
Continued
Figure 13 - Removing Firebox Bottom
INSTALLING FIREPLACE HOOD
1. Attach three zinc-colored shoulder screws to back of hood.
2. Insert hood into hood-mounting slots on firebox.
3. Hold hood in place. Insert two black Phillips screws through bottom of hood and tighten.
Hood
Hood Mounting Slot
Shoulder Screw
Screw
Figure 14 - Installing Fireplace Hood
INSTALLING FIREPLACE SCREEN
1. Insert each rod through nine rings lo­cated at top of screen.
2. Insert first rod into rear hole in left side of firebox. Fasten rod to rear hole near center of firebox using black shoulder screw.
3. Insert other rod into front hole on right side of firebox and fasten using remain­ing shoulder screw.
3. If using FA3700 blower accessory (Models UV32C and NLUV32C only), see Installing Blower Accessory for built-in installation, page 8.
Front Hole
Rear Hole
Screw
4. Attach flexible gas line to log set. See Connecting to Gas Supply in log set
Rod
Ring
owner’s manual.
5. Carefully insert firebox into rough opening.
6. Attach firebox to wall studs using nails or wood screws through holes in nail-
Screen
ing flange (see Figure 18, page 11).
7. Check all gas connections for leaks. See Checking Gas Connections in log set owner’s manual.
Figure 15 - Installing Fireplace Screen (Shown Without Fireplace Hood for Clarity)
BUILT-IN FIREBOX INSTALLATION
Built-in installation of this firebox involves installing firebox into a framed-in enclosure. This makes the front of firebox flush with wall. If installing a mantel above the firebox, but you must follow the clearances shown in Figure 7, page 8. Follow the instructions below to install the firebox in this manner.
1. Frame in rough opening. Use dimen­sions shown in Figure 16 for the rough opening
If installing in a corner, use dimensions shown in Figure 17 for the rough open­ing. The height is 33" (UV32C a nd NLUV32C) or 34 1/4" NLRUV32
), which is the same as the
(RUV32
and
wall opening in Figure 16.
2. Install gas piping to firebox location. This installation includes an approved flexible gas line (if allowed by local codes) after the manual shutoff valve. The flexible gas line must be the last item installed on the gas piping. See Connecting to Gas Supply in log set owner’s manual.
Height Front Width Depth
Model # Actual Framing Actual Framing Actual Framing UV32C 32 NLUV32C 32 RUV32 33 NLRUV32 33
3
/16" 33" 34 3/8" 34 3/4" 16 11/16" 17 3/4"
3
/16" 33" 34 3/8" 34 3/4" 16 11/16" 17 3/4"
11
/16" 34 1/4" 34 3/8" 34 3/4" 16 11/16" 17 3/4"
11
/16" 34 1/4" 34 3/8" 34 3/4" 16 11/16" 17 3/4"
10
Figure 16 - Rough Opening for Installing in Wall
39 3/8"
34 3/4"
55 5/8"
Figure 17 - Rough Opening for Installing in Corner
27 7/8"
105509
OWNER’S MANUAL
INSTALLATION
Continued
Nails or Wood Screws
Nailing Flanges
Figure 18 - Attaching Firebox to Wall Studs
PART S
Note:
Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they can’t supply original replacement part(s), call Fireplace Manufacturers Incorporated's Technical Service Depart­ment at 1-888-427-8322.
When calling Fireplace Manufacturers Inc., have ready
• your name
• your address
• model number of your heater
• how heater was malfunctioning
• type of gas used (propane or natural gas)
• purchase date Usually, we will ask you to return the defec-
tive part to the factory.
PARTS NOT UNDER WARRANTY
ACCESSORYREPLACEMENT
Purchase this heater accessory from your local dealer. If they can not supply this accessory, call Fireplace Manufacturers Incorporated's Parts Department at 1-800­888-2050 for referral information. You can also write to the address listed on the back page of this manual.
BLOWER ACCESSORY ­FA3700
Use with Models UV32C and NLUV32C only. The variable speed blower allows you to select the desired speed. The blower circulates heated air from the fireplace into the room.
TECHNICAL SERVICE
You may have further questions about in­stallation, operation, or troubleshooting. If so, contact Fireplace Manufacturers Incorporated's Technical Service Depart­ment at 1-888-427-8322.
Contact authorized dealers of this product. If they can’t supply original replacement part(s), call Fireplace Manufacturers Incorporated's Parts Department at 1-800­888-2050 for referral information.
When calling Fireplace Manufacturers Inc., have ready
• model number of your heater
• the replacement part number
105509
11
FIREPLACE MANUFACTURERS INC. UNVENTED 32" FIREBOX
ILLUSTRATED PART S BREAKDOWN
RUV32 NLRUV32
2*
3*
2*
17
13
17
1
7
16
16
4*
18
18
11
17
15
16
5
16
16
16
20
*Not Included with Model NLRUV32
12
9
18
16
19
8
10
6
14
12
105509
OWNER’S MANUAL
PARTS LIST
RUV32 NLRUV32
*Not Included with Model NLRUV32
This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 11 of this manual.
KEY PART NUMBER NO. RUV32 NLRUV32 DESCRIPTION QTY.
1 101872-03 101872-03 Firebox Top 1 2 101889-01 * Firebrick Retainer 3 3 101929-02 * Rear Firebrick 1 4 101932-02 * Side Firebrick 2 5 103207-01 103207-01 Outer Casing 1 6 103208-01 103208-01 Outer Shell Base 1 7 103245-01 101838-02CJ Firebox Wrapper 1 8 103297-01 103297-01 Assembly Screen 2 9 103217-01CK 103217-01CK Hood 1 10 103773-02CK 103773-02CK Front Assembly 1 11 103250-01CK 103250-01CK Firebox Bottom 1 12 103809-01 103809-01 Screen Rod 2 13 103816-01 103816-01 Firebox Insulation 1 14 101348-01 101348-01 Firebox Support 2 15 101357-03 101357-03 Outer Casing Top 1 16 M11084-26 Hex Head Screw, #10-16 49
M11084-26 Hex Head Screw, #10-16 46 17 098194-02 098194-02 Stand Off 3 18 098304-01 098304-01 Phillips Pan Head Screw, #10 13 19 099230-01 099230-01 Hex Head Screw 3 20 099230-02 099230-02 Shoulder Screw 2
105509
13
FIREPLACE MANUFACTURERS INC. UNVENTED 32" FIREBOX
ILLUSTRATED PART S BREAKDOWN
15
UV32C NLUV32C
2*
3*
2*
16
16
1
7
4*
16
18
18
11
5
16
17 16
9
12
20
*Not Included with Model NLUV32C
18
19
10
16
8
22
14
6
14
13
21
105509
OWNER’S MANUAL
PARTS LIST
UV32C NLUV32C
This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 11 of this manual.
KEY PART NUMBER NO. UV32C NLUV32C DESCRIPTION QTY.
1 101872-03 101872-03 Firebox Top 1 2 101889-01 * Firebrick Retainer 3 3 101929-02 * Rear Firebrick 1 4 101932-02 * Side Firebrick 2 5 103207-01 103207-01 Outer Casing 1 6 103208-01 103208-01 Outer Shell Base 1 7 103245-01 101838-01CJ Firebox Wrapper 1 8 103297-01 103297-01 Assembly Screen 2 9 103217-01CK 103217-01CK Hood 1 10 103773-01CK 103773-01CK Front Assembly 1 11 103250-01CK 103250-01CK Firebox Bottom 1 12 103809-01 103809-01 Screen Rod 2 13 M12461-2 M12461-2 Screw, Outlet Mounting 1 14 101348-01 101348-01 Firebox Support 2 15 101357-01 101357-01 Outer Casing Top 1 16 M11084-26 Hex Head Screw, #10-16 49
M11084-26 Hex Head Screw, #10-16 46 17 103771-01 103771-01 Strain Relief Fitting 1 18 098304-01 098304-01 Phillips Pan Head Screw, #10 13 19 099230-01 099230-01 Hex Head Screw 3 20 099230-02 099230-02 Shoulder Screw 2 21 103769-01 103769-01 Duplex Outlet 1 22 103457-01 103457-01 Button Plug 1
105509
*Not Included with Model NLUV32C
15
WARRANTY INFORMATION
KEEP THIS WARRANTY
Model Serial No. Date Purchased
Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.
We make no other warranty, expressed or implied.
LIMITED WARRANTY
VENT-FREE FIREBOX
Fireplace Manufacturers Incorporated warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.
This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper operating condition and an allowance for labor when provided by a Fireplace Manufacturers Incorporated Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this product and/or Fireplace Manufacturers Incorporated who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit.
This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.
TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURA­TION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO FOUR (4) YEARS ON ALL COMPONENTS AND FROM THE DATE OF FIRST PURCHASE; AND FIREPLACE MANUFACTURERS INCORPORATED’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND FIREPLACE MANUFACTURERS INCORPORATED SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state. For information about this warranty write:
2701 South Harbor Boulevard Santa Ana, CA 92704
105509 01
NOT A UPC
105509-01 Rev. A 03/99
Loading...