FMI VSHRN18M, VSHRP26M, GWRN18C, GWRN30TC, VSHRP16M User Manual

...
UNVENTED (VENT-FREE) INFRARED GAS HEATER
PFS
®
US
SAFETY INFORMATION AND INSTALLATION MANUAL
MODELS
GWRP16C, GWRN18C, GWRP26C, GWRN30C,
GWRP16TC, GWRN18TC, GWRP26TC, GWRN30TC
VSHRP16M, VSHRP16T, VSHRN18M, VSHRN18T,
VSHRP26M, VSHRP26T, VSHRN30M, AND VSHRN30T
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re department.
— Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
For more information, visit www.fmiproducts.com
Safety .................................................................. 2
TABLE OF CONTENTS
Local Codes......................................................... 4
Product Identication ........................................... 4
Unpacking............................................................ 4
Product Features ................................................. 4
Air For Combustion and Ventilation ..................... 5
Installation ........................................................... 7
Operation ........................................................... 14
Inspecting Heater .............................................. 17
Cleaning and Maintenance ................................ 17
SAFETY
Specications .................................................... 18
Troubleshooting ................................................. 19
Parts .................................................................. 22
Accessories ....................................................... 27
Replacement Parts ............................................ 27
Service Publications .......................................... 27
Service Hints ..................................................... 27
Technical Service............................................... 27
Warranty ..............................................Back Cover
WARNING: Improper
installation, adjustment,
alteration, service or main-
tenance can cause injury or property damage. Refer
to this manual for correct
installation and operation­al procedures. For assis-
tance or additional infor-
mation consult a qualied installer, service agency or the gas supplier.
WARNING: This is an
unvented gas-red heat­er. It uses air (oxygen)
from the room in which
it is installed. Provisions for adequate combustion
and ventilation air must
be provided. Refer to Air for Combustion and Ven­tilation section on page 5
of this manual.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
www.fmiproducts.com
This appliance may be in­stalled in an aftermarket,*
perma n ently locat e d, manufactured (mobile) home, where not prohib­ited by local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
WARNING: This product con-
tains and/or generates chemicals
known to the State of California
to cause cancer or birth defects or other reproductive harm.
IMPORTANT: Read this owner’s manual carefully and completely be for e t rying to assemble, operate or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs
of carbon monoxide poisoning resemble the
u, with headaches, dizziness or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more af­fected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the inu­ence of alcohol and those at high altitudes.
125311-01A2
SAFETY
Continued
Natural and Propane/LP Gas: Natural and propane/LP gases are odorless. An odor­making agent is added to these gases. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
WARNING: Any change to
this heater or its controls can
be dangerous.
WARNING: Do not use a
blower insert, heat exchanger insert or other accessory not ap­proved for use with this heater.
Due to high temperatures, the appliance should be located out of trafc and away from furniture and draperies.
Do not place clothing or other ammable material on or near the appliance. Never place any objects on the heater.
Surface of heater becomes very hot when running heater. Keep
children and adults away from
hot surface to avoid burns or clothing ignition. Heater will
remain hot for a time after shut-
down. Allow surface to cool before touching.
Carefully supervise young chil-
dren when they are in the room
with heater.
Make sure grill guard is in place before running heater.
125311-01A 3
www.fmiproducts.com
Keep the appliance area clear and free from combustible ma­terials, gasoline and other am­mable vapors and liquids.
1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors.
3. This heater shall not be installed in a bedroom or bathroom.
4. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not
use any phone in your building
• immediately call your gas supplier from
a neighbor’s phone. Follow the gas sup­plier’s instructions
• if you cannot reach your gas supplier,
call the re department
5. Manual Control Models Always run heater with plaque control knob at the 1, 2, 3 or 4 locked positions. Never set con­trol knob between locked positions. Poor combustion and higher levels of carbon monoxide may result.
6. This heater needs fresh, outside air ventila­tion to run properly. This heater has an Oxy­gen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, page 5.
7. Keep all air openings in front and bottom of heater clear and free of debris. This will insure enough air for proper combustion.
8. If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.
9. Do not run heater
• where ammable liquids or vapors are used or stored
• under dusty conditions
10. Do not use heater if any part has been under water. Immediately call a qualied service technician to inspect the room
heater and to replace any part of the
control system and any gas control which has been under water.
SAFETY
Ignitor Button
Control Knob
Heater Cabinet
Front Panel
Plaque
Grill Guard
Continued
11. Turn off and unplug heater and let cool before servicing. Only a qualied service person should service and repair heater.
12. Operating heater above elevations of 4,500 feet (1,371 m) could cause pilot outage.
13. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. (45 kg) capacity.
LOCAL CODES
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel
Gas Code ANSI Z223/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park Quincy, MA 02269
14. Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furni­ture.
15. Provide adequate clearances around air openings.
State of Massachusetts: The installa­tion must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natural gas-red supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in the
Commonwealth of Massachusetts.
(actual heater may vary from illustration
PRODUCT
IDENTIFICATION
Figure 1 - Vent-Free Gas Heater
www.fmiproducts.com
UNPACkING
1. Remove heater from carton.
2. Remove all protective packaging applied to heater for shipment.
3. Check heater for any shipping damage. If heater is damaged call FMI PRODUCTS,
LLC at 1-866-328-4537 for replacement
parts before returning to dealer.
PRODUCT FEATURES
SAFETY DEVICE
This heater has a pilot with an Oxygen Deple­tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
IGNITION SYSTEM
Some models are equipped with a piezo ignitor that requires no matches, batteries or other sources to light heater.
Other heaters are equipped with an electronic ignitor to light heater fuel supply.
THERMOSTATIC HEAT CONTROL
(Thermostat Models Only)
Thermostat models have a thermostat sens­ing bulb and a control valve. This results in the greatest heater comfort. This can also result in lower gas bills.
125311-01A4
AIR FOR COMBUSTION AND VENTILATION
WARNING: This heater shall
not be installed in a room or space unless the required volume of in­door combustion air is provided by the method described in the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or applicable lo-
cal codes. Read the following in­structions to insure proper fresh air for this and other fuel-burning appliances in your home.
Today’s homes are built more energy efcient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. Dur­ing heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy efcient, your home needs to breathe. Fresh air must enter your home. All fuel-burning ap­pliances need fresh air for proper combustion and ventilation.
Exhaust fans, heaters, clothes dryers and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
PROVIDING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas Code. ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three
following ventilation classications:
1. Unusually Tight Construction
2. Unconned Space
3. Conned Space The information on pages 5 through 7 will
help you classify your space and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of un­usually tight construction, you must provide additional fresh air.
Unusually tight construction is dened as
construction where:
a. walls and ceilings exposed to the out-
side atmosphere have a continuous water vapor retarder with a rating of one perm (6x10 less with openings gasketed or sealed
and
b. weather stripping has been added on
openable windows and doors and
c. caulking or sealants are applied to
areas such as joints around window and door frames, between sole plates and oors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical and gas lines and at other openings.
If your home meets all of the three criteria
above, you must provide additional fresh air.
See Ventilation Air From Outdoors, page 7. If your home does not meet all of the three
criteria above, proceed to Determining Fresh-Air Flow For Heater Location.
Conned Space and Unconned Space
The National Fuel Gas Code ANSI Z223.1/ NFPA 54 denes a conned space as a space
whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the ag­gregate input rating of all appliances installed in that space and an unconned space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the un­conned space.
* Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.
-11
kg per pa-sec-m2) or
125311-01A 5
www.fmiproducts.com
AIR FOR COMBUSTION AND VENTILATION
Continued
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION
Determining if You Have a Conned or Unconned Space
Use this work sheet to determine if you have a conned or unconned space.
Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
1. Determine the volume of the space (length x width x height).
Length x Width x Height =__________cu. ft.
(volume of space)
Example: Space size 20 ft. (6.1m) (length) x
16 ft. (4.88m) (width) x 8 ft. (2.44 m) (ceiling height) = 2,560 cu. ft. (72.49 m2)(volume of space)
If additional ventilation to adjoining room
is supplied with grills or openings, add the volume of these rooms to the total volume of the space.
2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.
________ (volume of space) x 20 = (Maxi-
mum Btu/Hr the space can support)
Example: 2,560 cu. ft. (72.49 m2) (volume of
space) x 20 = 51,200 (maximum Btu/Hr the space can support)
3. Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free heater _________ Btu/Hr Gas water heater* _________ Btu/Hr Gas furnace _________ Btu/Hr Vented gas heater _________ Btu/Hr Gas heater logs _________ Btu/Hr Other gas appliances* + _________ Btu/Hr Total = _________Btu/Hr * Do not include direct-vent gas appliances.
Direct-vent draws combustion air from the outdoors and vents to the outdoors.
Example:
Gas water heater _________ Btu/Hr Vent-free heater + _________Btu/Hr Total = _________Btu/Hr
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/ Hr used.
_______ Btu/Hr (maximum can support) _______ Btu/Hr (actual amount used) Example: 51,200 Btu/ Hr (ma ximum the
space can support)
60,000 Btu/Hr (actual amount of
Btu/Hr used)
40,000 20,000
60,000
www.fmiproducts.com
The space in the example is a conned space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an
adjoining room. If the extra space provides an unconned space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building.
B. Vent room directly to the outdoors. See
Ventilation Air From Outdoors, page 7.
C. Install a lower Btu/Hr heater, if lower Btu/Hr
size makes room unconned.
If the actual Btu/Hr used is less than the maxi­mum Btu/Hr the space can support, the space is an unconned space. You will need no additional fresh air ventilation.
WARNING: If the area in which
the heater may be operated does not meet the required volume for indoor combustion air, combus­tion and ventilation air shall be provided by one of the methods described in the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code,
or applicable local codes.
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconned space. When ventilating to an adjoining unconned space, you must provide two permanent openings: one within 12" (30.5 cm) of the ceiling and one within 12" (30.5 cm) of the oor on the wall connecting the two spaces (see options 1 and 2, Figure 2, page
7). You can also remove door into adjoining room (see option 3, Figure 2, page 7). Follow
the National Fuel Gas Code, ANSI Z223.1/ NFPA 54, Air for Combustion and Ventilation
for required size of ventilation grills or ducts.
125311-01A6
AIR FOR COMBUSTION AND VENTILATION
Or
Remove Door into Adjoining
Room,
Option 3
Ventilation Grills
Into Adjoining Room,
Option 2
12"
12"
Ventilation
Grills into Adjoining
Room,
Option 1
Outlet Air
Ventilated Attic
Outlet Air
Inlet Air
Inlet Air
Ventilated
Crawl Space
To
Crawl
Space
To Attic
Continued
ing and one within 12" (30.5 cm) of the oor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the Na-
tional Fuel Gas Code, ANSI Z223.1/NFPA 54,
Air for Combustion and Ventilation for required size of ventilation grills or ducts.
IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat­controlled power vent. Heated air entering the attic will activate the power vent.
Figure 2 - Ventilation Air from Inside
Building
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" (30.5 cm) of the ceil-
Figure 3 - Ventilation Air from Outdoors
INSTALLATION
NOTICE: This heater is intended
for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri­mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
WARNING: A qualied ser­vice person must install heater. Follow all local codes.
WARNING: This appliance is equipped for either natural gas or propane/LP gas but not both. Gas type is indicated on the rating plate. Field conversion is not permitted.
125311-01A 7
www.fmiproducts.com
CHECK GAS TYPE
Use only the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install heater. Call dealer where you bought heater for proper type heater.
INSTALLATION ITEMS
Before installing heater, make sure you have the items listed below.
• for propane/LP gas, external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• ground joint union
• sediment trap
• tee joint
• pipe wrench
• for natural gas, test gauge connection*
• hardware packet (included)
- wall anchor (4) 095112-02
- red key (1) 095116-01
- pan head screw, black (4) 097403-02
- nylon spacer (2) 099064-02
- clip (1) 099123-01
- Phillips head screw, silver (4) 100159-02
* An equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge con­nection. The optional equipment shutoff valve can be purchased from your dealer.
INSTALLATION
Minimum From Sides Of Heater
2" (5.1 cm)
FLOOR
CEILING
36" (91.5 cm) Minimum
Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material
Left Side
Right Side
10" (25.4 cm)
36"
(91.5 cm)
Clip
Thermostat Sensing Bulb
Continued
LOCATING HEATER
This heater is designed to be mounted on a wall.
WARNING: Maintain the
minimum clearances shown
in Figure 4. If you can, provide greater clearances from oor, ceiling and joining wall.
You can locate heater on oor, away from a wall. An optional oor mounting stand is needed. Purchase the oor mounting stand from your dealer. See Accessories, page 27, if stand is not included with your heater.
WARNING: Never install the
heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, cloth­ing or other ammable objects are less than 36" (91.5 cm) from the front, top or sides of
the heater
• as a replace insert
• in high trafc areas
• in windy or drafty areas
IMPORTANT: Vent-free heaters add moisture to the air. Although this is benecial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Combustion and Ventila- tion, page 5. If high humidity is experienced, a dehumidier may be used to help lower the water vapor content in the air.
For convenience and efciency, install heater
• where there is easy access for operation, inspection and service
• in coldest part of room
If not included with your heater, an optional fan kit is available from your dealer. See Acces- sories, page 27. If planning to use fan, locate heater near an electrical outlet (see page 16).
CAUTION: If you install the
heater in a home garage
• heater pilot and burner must be at least 18" (45.7 cm) above oor
• locate heater where moving
vehicle will not hit it
CAUTION: This heater cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning uids, oil or kerosene lamps, etc.) in the
air exist, may discolor walls or
cause odors.
www.fmiproducts.com
Figure 4 - Mounting Clearances As
Viewed From Front of Heater
THERMOSTAT SENSING BULB
(Thermostat Models Only)
The thermostat sensing bulb has been placed below the heater.
1. Place clip on thermostat sensing bulb as shown in Figure 5. Clip is provided in hard­ware package.
2. Snap clip into upper mounting hole as shown in Figure 5. Mounting hole is located on lower left edge on back of heater. Make sure ther­mostat sensing bulb is pointing up.
Figure 5 - Attaching Thermostat Sensing
Bulb
125311-01A8
INSTALLATION
Screw
Front Panel
16"
Min.
14"
12"
Min.
Ad joi ni ng Wa ll
14"
Ad joi ni ng Wa ll
Only Insert Mounting
Screws Through Last
Hole On Each End
Only Insert Mounting Screws Through Last
Hole On Each End
Floor
Floor
19 3/4"
Min.
19 3/4"
Min.
5 Plaque Heaters
3 Plaque Heater
Continued
INSTALLING HEATER TO WALL
Mounting Bracket
Locate mounting bracket in heater carton. Re­move mounting bracket from heater carton.
Figure 6 - Mounting Bracket
Removing Front Panel Of Heater
1. Remove the four painted screws, two on each side of front panel.
2. Pull bottom of front panel forward, then out.
3. Remove any remaining packaging materials.
MARKING SCREW LOCATIONS
1. Tape mounting bracket to wall where heater will be located. Make sure mount­ing bracket is level.
WARNING: Maintain minimum
clearances shown in Figure 8. If you can, provide greater clearanc­es from oor and joining wall.
2. Mark screw locations on wall (see Figure 8).
Note: Only mark last hole on each end of
mounting bracket. Insert mounting screws through these holes only.
3. Remove tape and mounting bracket from wall.
Figure 7 - Removing Front Panel of Heater
(actual heater may vary from Illustration)
Methods For Attaching Mounting Bracket
To Wall
Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 14" (35.6 cm) apart from their cen­ters. Attach mounting bracket to wall in one of two ways:
1. Attaching to wall stud
2. Attaching to wall anchor Attaching to Wall Stud: This method pro­vides the strongest hold. Insert mounting screws through mounting bracket and into wall studs. Attaching to Wall Anchor: This method al­lows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry). Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.
125311-01A 9
www.fmiproducts.com
Figure 8 - Mounting bracket Clearances
Attaching Mounting Bracket To Wall
Note: Wall anchors, mounting screws and spacers are in hardware package. The hard­ware package is provided with heater.
Attaching To Wall Stud Method
For attaching mounting bracket to wall studs
1. Drill holes at marked locations using 9/64" drill bit.
2. Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.
3. Insert mounting screws through bracket and into wall studs.
4. Tighten screws until mounting bracket is rmly fastened to wall studs.