Fluke TiX520, TiX560 Data Sheet

TiX560 and TiX520
Infrared Cameras
The Fluke Expert Series
PREMIUM IMAGE QUALITY
SPATIAL RESOLUTION
TiX560 and Ti X520
1.31 mRad
RESOLUTION
TiX560 and Ti X520
320 x 240 (76,800 pixels) and 640x480 (307,200 pixels) with SuperResolution Mode
FILTER MODE (NETD IMPROVEMENT)
TiX560
≤ 0.03 °C at 30 °C target temp (30 mK)
TiX520
≤ 0.04 °C at 30 °C target temp (40 mK
Technical Data
Your view of infrared technology is about to change 180°
Easily navigate over, under and around objects with the
180° articulating lens and see the image before you capture it
5.7 inch responsive touchscreen LCD in its class¹—
150 % more viewing area
Enhanced image quality and temperature
measurement accuracy – turn your 320 x 240 images
into 640 x 480 images, that’s 4x’s the resolution and pixels with SuperResolution
Get an in-focus image with the touch of a button. LaserSharp
®
Auto Focus, exclusive to Fluke, uses a
built-in laser distance meter that calculates and displays the distance to your designated target with pinpoint accuracy²
See the details you need with smart lenses—2x and 4x telephoto, wide angle, and 25 micron macro— no calibration required, interchangeable between compatible cameras
See, save and share from the field and connect to the
largest selection of wireless test and measurement tools with Fluke Connect
1
Compared to industrial handheld infrared cameras with 320x240 detector
resolut ion as of October 14, 2014.
2
Up to 30 meters (100 feet).
3
Compared to a 3.5 inch screen.
3
TEMPERATURE RANGE
TiX560
-20 °C to +1200 °C (-4 °F to +2192 °F)
TiX520
-20 °C to +850 °C (-4 °F to +1562 °F)
IMAGE SHARPENING
TiX560
Image sharpening improves image clarity and quality
Get tough shots from any angle wi th a 180° degree rotating lens and the only
5.7 inch LCD.
LaserSharp® Auto Focus uses a built in laser distance meter that calculates and displays t he distance to your designated target with pinpoint accuracy.
Detailed specifications
TiX560 TiX520
Key Features
IFOV with sta ndard lens (spati al res olution) 1.31 mRad, D:S 764:1
Detector resolution 320 x 240 (76,8 00 pi xels)
Field of view 24 °H x 17 °V
Minimum focus distanc e 15 cm (approx. 6 in)
IFOV with opt iona l 2x telephoto smart lens 0.65 mRad , D:S 1528:1
Field of view 12 °H x 9 °V
Minimum focus distanc e 45 cm (approx. 18 in)
IFOV with opt iona l 4x telephoto smart lens 0.33 mRad, D:S 3056:1
Field of view 6.0 °H x 4.5 °V
Minimum focus distanc e 1.5 m (approx. 5 ft)
IFOV with opt iona l wide-angle sma rt len s 2.62 mRad, D:S 399:1
Field of view 46 °H x 34 °V
Minimum focus distanc e 15 cm (approx. 6 in)
Mini mum mi cron spot size with optional macro s mar t lens
Field of view 36.1° X 27.1°
Working distance ~8 mm (0.3 i n) to ~14 mm (0.6 in) with opt ima l at 10 mm (0.4 in)
SuperResolution On camera and i n software In sof twa re
Image sharpening Yes
LaserSharp
® Auto Focus Yes, for con sistently in-focus i mages. Ever y. Single. Time.
Laser distance meter Yes, calculates di stance to the target for precis ely foc used images and displays di stance on sc reen
Advanced ma nual focu s Yes
Streami ng video (remote display) Via HDMI or Wi Fi hot s pot in r emote control mode Via HDMI
Touchscreen display (capacit ive) 14.4 cm (5.7 in) diagonal land scape color VGA (640 x 480) LC D wit h back light
Wireless connectivity Yes
Wireless compatibility Yes, to PC, i Phone
Fluke Connect
Fluke Connect
IR-Fusion
AutoBlend
app compatible Yes (where available)
tool compatible Yes (where available). Connec ts wirele ss to select F luke Connect en abled tools. Five simultaneous connections supported
® technology Yes
mode Yes
® and iPad
®
(iOS 4s a nd later), Android™ 4.3 and up, and Wi Fi to L AN (where ava ila ble)
Picture-In-Picture (PIP) Yes
Continuous AutoBlend
Set AutoBlend™ level ac ross c onti nuum
Rugged, ergonomic desig n Rotata ble (ar tic ulating lens) >180 degrees
Thermal sensitivit y (NETD) ≤ 0.045 °C at 30 °C ta rget temp (45 mK ) ≤ 0.05 °C at 30 ° C target temp (50 mK)
Filter Mode (N ETD improvement) ≤ 0.03 °C at 30 °C target temp (30 mK) ≤ 0.04 °C at 30 °C tar get temp (4 0 mK)
Level and span Smooth auto and manual scaling
Touchscreen adjustable level/spa n Yes. Span and level can be easy a nd qu ickly set by simply touching the screen
Fast auto toggle b etwe en manual and auto modes Yes
Fast auto-rescale in manual mode Yes
Minimum s pan (i n manual mode) 2.0 °C (3.6 ° F)
Minimum s pan (i n auto mode) 3.0 °C (5.4 °F)
Built-in digital camera (v isible light) 5 megapixel industr ial performance
Frame rate 60 Hz or 9 H z vers ions
Laser pointer Yes
LED light (torch) Yes
Digital Zoom 2x, 4x, 8x 2x, 4x
25 microns
2 Fluke Corporation TiX560 and TiX520 Infrared Cameras: The Fluke Expert Series
Loading...