Fluke Industrial/Commercial
Thermal Imagers
Models: Ti25, Ti10 and Ti9
High performance thermal
imagers have never been this
affordable. This rugged. Or,
this easy to use … until now.
The perfect tools to add to your problem solving arsenal. Built
for tough work environments, these high-performance, fully
Ti25
Ti10
Ti9
Industrial, mechanical,
electromechanical
and general building
maintenance.
radiometric imagers are ideal for troubleshooting electrical
installations, electro-mechanical equipment, process equipment,
HVAC/R equipment and others.
• The Fluke Ti10 and Ti25 thermal imagers come with enhanced
problem detection and analysis capabilities with IR-Fusion®
Technology. Simply scroll through the different viewing modes
quickly to better identify trouble areas in Full IR thermal, picturein-picture, or automatic blend visual and thermal images.
• Optimized for field use in harsh work environments
– Engineered and tested to withstand a 2 m (6.5 ft) drop
– Withstands dust and water—tested to an IP54 rating.
• Delivers the clear, crisp images needed to find problems fast.
• Identify even small temperature differences that could indicate
problems with excellent thermal sensitivity (NETD).
• Intuitive, three-button menu is easy to use—simply navigate with
the push of a thumb.
• No need to carry pen and paper—record findings by speaking
into the camera. Voice comments are saved along with individual
images for future reference (Ti25 only)
Fluke. Not just infrared, infrared you can use.
Technical Data
®
Process, refractory
insulation, tank and
vessel levels, steam
systems and traps,
pipes and valves, etc.
Electrical, unbalanced
loads, overloaded
systems, wiring
mistakes or
component failure, etc.
Patented Fluke IR-Fusion® Technology
More than picture in picture
Infrared images alone can be difficult to understand, which is why Fluke pioneered IR-Fusion,
a revolutionary marriage of visible and infrared
images never before seen in commercial or
industrial thermal imagers. Automatically
capturing a visible image with every infrared
image allows to you always know exactly what
you’re looking at.
Not all fusion is created equal
Don’t be fooled by imitators. No other manufacturer
can boast on-camera blending. Compare the images.
Only Fluke has mastered the ability to create the
industry’s only transparent, perfectly blended and
aligned visible and infrared images.
Fluke Competitor
Detailed specifications
Temperature
Ti25 Ti10 Ti9
Temperature measurement range
(not calibrated below -10 °C)
Temperature measurement
accuracy
-20 °C to +350 °C (-4 °F to +662 °F) -20 °C to +250 °C (-4 °F to +482 °F) -20 °C to +250 °C (-4 °F to +482 °F)
± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
± 5 °C or 5 % (at 25 °C nominal,
whichever is greater)
On-screen emissivity correction Yes, and in software In software only
On-screen reflected background
temperature compensation
Yes, and in software In software only
Imaging performance
Image capture frequency 9 Hz refresh rate
Detector type 160 X 120 Focal Plane Array, uncooled microbolometer
Thermal sensitivity (NETD) ≤ 0.09 °C at 30 °C target temp. (90 mK) ≤ 0.13 °C at 30 °C target temp. (130 mK) ≤ 0.20 °C at 30 °C target temp. (200 mK)
Visual (visible light) camera Industrial performance 1.3 megapixels
Minimum (visible light)
46 cm (approx. 18 in)
No visible camera
focus distance
Infrared field of view 23 ° x 17 °
Spatial resolution (IFOV) 2.5 mRad
Minimum infrared focus distance 15 cm (approx. 6 in)
Focus mechanism Manual, one-handed Smart Focus capability
Image presentation
Palettes
Standard Ironbow, Blue-Red, High Contrast,
Amber, Hot Metal, Grayscale
Ironbow, Blue-Red,
High Contrast, Grayscale
Level and span Smooth auto-scaling and manual scaling of level and span
Fast auto toggle between manual
and auto modes
Yes —
Fast auto-rescale in manual mode Yes —
Minimum span (in manual mode) 2.5 °C (4.5 °F) 5 °C (9 °F)
Minimum span (in auto mode) 5 °C (9 °F) 10 °C (18 °F)
IR-Fusion
Automatically aligned (parallax
corrected) visual and IR blending
Picture-In-Picture (PIP) Three levels of on-screen IR blending
® information
Yes
100 % IR displayed in center of LCD
No IR-Fusion
displayed in center of LCD (AutoBlend)
Full screen infrared Three levels of on-screen IR blending
displayed on LCD (AutoBlend)
Voice annotation 60 seconds maximum recording time per
image; reviewable playback on imager
— —
100 % IR displayed on LCD
Image capture and data storage
The Ti25 allows user to adjust palette,
blending, level, span,
® mode, emissivity, and reflected
IR-Fusion
background temperature compensation on
— —
a captured image before it is stored.
Image capture, review, save
mechanism
One-handed image capture, review, and save capability
Storage medium SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images
each with 60 seconds voice annotations (when available), or 3000 basic bitmap (.bmp) images transferrable
to PC via included multi-format USB card reader
File formats Non-radiometric (.bmp) or fully-radiometric (.is2)
No analysis software required for non-radiometic bitmap (.bmp) files
Export file formats w/SmartView
software
®
BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Memory review Sequential image navigation and review
2 Fluke Corporation Ti25, Ti10 and Ti9 Industrial/Commercial Thermal Imagers