Fluke Ti9 Specifications

Fluke Industrial/Commercial
Thermal Imagers
Models: Ti25, Ti10 and Ti9
High performance thermal imagers have never been this affordable. This rugged. Or, this easy to use … until now.
The perfect tools to add to your problem solving arsenal. Built for tough work environments, these high-performance, fully
Ti25
Ti10
Ti9
Industrial, mechanical, electromechanical and general building maintenance.
radiometric imagers are ideal for troubleshooting electrical installations, electro-mechanical equipment, process equipment, HVAC/R equipment and others.
The Fluke Ti10 and Ti25 thermal imagers come with enhanced problem detection and analysis capabilities with IR-Fusion® Technology. Simply scroll through the different viewing modes quickly to better identify trouble areas in Full IR thermal, picture­in-picture, or automatic blend visual and thermal images.
Optimized for field use in harsh work environments
– Engineered and tested to withstand a 2 m (6.5 ft) drop – Withstands dust and water—tested to an IP54 rating.
Delivers the clear, crisp images needed to find problems fast.
Identify even small temperature differences that could indicate
problems with excellent thermal sensitivity (NETD).
Intuitive, three-button menu is easy to use—simply navigate with the push of a thumb.
No need to carry pen and paper—record findings by speaking into the camera. Voice comments are saved along with individual images for future reference (Ti25 only)
Fluke. Not just infrared, infrared you can use.
Technical Data
®
Process, refractory insulation, tank and vessel levels, steam systems and traps, pipes and valves, etc.
Electrical, unbalanced loads, overloaded systems, wiring mistakes or component failure, etc.
Patented Fluke IR-Fusion® Technology
More than picture in picture
Infrared images alone can be difficult to under­stand, which is why Fluke pioneered IR-Fusion, a revolutionary marriage of visible and infrared images never before seen in commercial or industrial thermal imagers. Automatically capturing a visible image with every infrared image allows to you always know exactly what you’re looking at.
Not all fusion is created equal
Don’t be fooled by imitators. No other manufacturer can boast on-camera blending. Compare the images. Only Fluke has mastered the ability to create the industry’s only transparent, perfectly blended and aligned visible and infrared images.
Fluke Competitor
Detailed specifications
Temperature
Ti25 Ti10 Ti9
Temperature measurement range (not calibrated below -10 °C)
Temperature measurement accuracy
-20 °C to +350 °C (-4 °F to +662 °F) -20 °C to +250 °C (-4 °F to +482 °F) -20 °C to +250 °C (-4 °F to +482 °F)
± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
± 5 °C or 5 % (at 25 °C nominal,
whichever is greater) On-screen emissivity correction Yes, and in software In software only On-screen reflected background
temperature compensation
Yes, and in software In software only
Imaging performance
Image capture frequency 9 Hz refresh rate Detector type 160 X 120 Focal Plane Array, uncooled microbolometer Thermal sensitivity (NETD) ≤ 0.09 °C at 30 °C target temp. (90 mK) ≤ 0.13 °C at 30 °C target temp. (130 mK) ≤ 0.20 °C at 30 °C target temp. (200 mK) Visual (visible light) camera Industrial performance 1.3 megapixels Minimum (visible light)
46 cm (approx. 18 in)
No visible camera focus distance Infrared field of view 23 ° x 17 ° Spatial resolution (IFOV) 2.5 mRad Minimum infrared focus distance 15 cm (approx. 6 in) Focus mechanism Manual, one-handed Smart Focus capability
Image presentation
Palettes Standard Ironbow, Blue-Red, High Contrast,
Amber, Hot Metal, Grayscale
Ironbow, Blue-Red,
High Contrast, Grayscale Level and span Smooth auto-scaling and manual scaling of level and span Fast auto toggle between manual
and auto modes
Yes
Fast auto-rescale in manual mode Yes — Minimum span (in manual mode) 2.5 °C (4.5 °F) 5 °C (9 °F) Minimum span (in auto mode) 5 °C (9 °F) 10 °C (18 °F)
IR-Fusion
Automatically aligned (parallax corrected) visual and IR blending
Picture-In-Picture (PIP) Three levels of on-screen IR blending
® information
Yes
100 % IR displayed in center of LCD
No IR-Fusion
displayed in center of LCD (AutoBlend)
Full screen infrared Three levels of on-screen IR blending
displayed on LCD (AutoBlend)
Voice annotation 60 seconds maximum recording time per
image; reviewable playback on imager
100 % IR displayed on LCD
Image capture and data storage
The Ti25 allows user to adjust palette,
blending, level, span,
® mode, emissivity, and reflected
IR-Fusion background temperature compensation on
a captured image before it is stored.
Image capture, review, save mechanism
One-handed image capture, review, and save capability
Storage medium SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images
each with 60 seconds voice annotations (when available), or 3000 basic bitmap (.bmp) images transferrable
to PC via included multi-format USB card reader
File formats Non-radiometric (.bmp) or fully-radiometric (.is2)
No analysis software required for non-radiometic bitmap (.bmp) files
Export file formats w/SmartView software
®
BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Memory review Sequential image navigation and review
2 Fluke Corporation Ti25, Ti10 and Ti9 Industrial/Commercial Thermal Imagers
General specifications
Operating temperature -10 °C to +50 °C (14 °F to 122 °F) Storage temperature -20 °C to +50 °C (-4 °F to 122 °F) without batteries Relative humidity 10 % to 95 % non-condensing Display 9.1 cm (3.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight and clear protective cover Controls and adjustments User selectable temperature scale (°C/°F)
Software SmartView Batteries Internal rechargeable battery pack (included) Battery life Three to four hours continuous use (assumes 50 % brightness of LCD) Battery charge time 2.5 hours to full charge AC battery charging AC adapter/charger (110 V ac to 220 V ac, 50/60 Hz) (included), charges battery while imager is operating or turned off, ac mains
AC operation AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz). AC mains adapters included. Power saving Sleep mode activated after five minutes of inactivity, automatic power off after 30 minutes of inactivity Safety standards CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01 Electromagnetic compatibility Meets all applicable requirements in EN61326-1:2006 C Tick IEC/EN 61326-1 US FCC CFR 47, Part 15 Class B Vibration 0.03 g2/Hz (3.8 grms), IEC 68-2-6 Shock 25 g, IEC 68-2-29 Drop 2 meter (6.5 feet) Size (H x W x L) 26.7 cm x 12.7 cm x 15.2 cm (10.5 in x 5.0 in x 6.0 in) Weight (battery included) 1.2 kg (2.6 lb) Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions) Warranty Two-years (standard) Recommended calibration cycle Two-years (assumes normal operation and normal wear) Supported Languages Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish,
Language selection Time/Date set Emissivity selection (Ti25 only) Reflected background temperature compensation (Ti25 only) User selectable hot spot and cold spot, and center point on the image (Ti25 only) (other custom markers and shapes in SmartView software) User selectable backlight: “Full Bright” or “Auto”
® full analysis and reporting software included
adapters included.
Swedish, Traditional Chinese, and Turkish
®
Ordering information
FLK-Ti25 9Hz Thermal Imager FLK-Ti10 9Hz Thermal Imager FLK-Ti9 9Hz Thermal Imager
Included
Thermal imager, ac power supply/battery charger (including mains adapters); SD memory card; multi-format USB memory card reader for downloading images into your computer; SmartView® software with free software upgrades for life; rugged, hard carrying case; soft transport bag; adjustable hand strap; printed users manual; warranty registration card.
Optional accessories
TI-CAR-CHARGER Thermal Imager Vehicle Charger TI-VISOR Thermal Imager Visor BOOK-ITP Introduction to Thermography Principles Book TI-TRIPOD Tripod Mounting Base Accessory
3 Fluke Corporation Ti25, Ti10 and Ti9 Industrial/Commercial Thermal Imagers
Fluke. Not just infrared. Infrared you can use.
Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands
For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com
©2009-2011 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 7/2011 3467124G D-EN-N
Modification of this document is not permitted without written permission from Fluke Corporation.
Loading...