High performance thermal
imagers have never been this
affordable. This rugged. Or,
this easy to use … until now.
The perfect tools to add to your problem solving arsenal. Built
for tough work environments, these high-performance, fully
Ti25
Ti10
Ti9
Industrial, mechanical,
electromechanical
and general building
maintenance.
radiometric imagers are ideal for troubleshooting electrical
installations, electro-mechanical equipment, process equipment,
HVAC/R equipment and others.
• The Fluke Ti10 and Ti25 thermal imagers come with enhanced
problem detection and analysis capabilities with IR-Fusion®
Technology. Simply scroll through the different viewing modes
quickly to better identify trouble areas in Full IR thermal, picturein-picture, or automatic blend visual and thermal images.
• Optimized for field use in harsh work environments
– Engineered and tested to withstand a 2 m (6.5 ft) drop
– Withstands dust and water—tested to an IP54 rating.
• Delivers the clear, crisp images needed to find problems fast.
• Identify even small temperature differences that could indicate
problems with excellent thermal sensitivity (NETD).
• Intuitive, three-button menu is easy to use—simply navigate with
the push of a thumb.
• No need to carry pen and paper—record findings by speaking
into the camera. Voice comments are saved along with individual
images for future reference (Ti25 only)
Fluke. Not just infrared, infrared you can use.
Technical Data
®
Process, refractory
insulation, tank and
vessel levels, steam
systems and traps,
pipes and valves, etc.
Electrical, unbalanced
loads, overloaded
systems, wiring
mistakes or
component failure, etc.
Patented Fluke IR-Fusion® Technology
More than picture in picture
Infrared images alone can be difficult to understand, which is why Fluke pioneered IR-Fusion,
a revolutionary marriage of visible and infrared
images never before seen in commercial or
industrial thermal imagers. Automatically
capturing a visible image with every infrared
image allows to you always know exactly what
you’re looking at.
Not all fusion is created equal
Don’t be fooled by imitators. No other manufacturer
can boast on-camera blending. Compare the images.
Only Fluke has mastered the ability to create the
industry’s only transparent, perfectly blended and
aligned visible and infrared images.
FlukeCompetitor
Detailed specifications
Temperature
Ti25Ti10Ti9
Temperature measurement range
(not calibrated below -10 °C)
Temperature measurement
accuracy
-20 °C to +350 °C (-4 °F to +662 °F) -20 °C to +250 °C (-4 °F to +482 °F)-20 °C to +250 °C (-4 °F to +482 °F)
± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
± 5 °C or 5 % (at 25 °C nominal,
whichever is greater)
On-screen emissivity correction Yes, and in softwareIn software only
On-screen reflected background
temperature compensation
Yes, and in softwareIn software only
Imaging performance
Image capture frequency9 Hz refresh rate
Detector type160 X 120 Focal Plane Array, uncooled microbolometer
Thermal sensitivity (NETD)≤ 0.09 °C at 30 °C target temp. (90 mK) ≤ 0.13 °C at 30 °C target temp. (130 mK) ≤ 0.20 °C at 30 °C target temp. (200 mK)
Visual (visible light) cameraIndustrial performance 1.3 megapixels
Minimum (visible light)
46 cm (approx. 18 in)
No visible camera
focus distance
Infrared field of view23 ° x 17 °
Spatial resolution (IFOV)2.5 mRad
Minimum infrared focus distance15 cm (approx. 6 in)
Focus mechanismManual, one-handed Smart Focus capability
Image presentation
Palettes
StandardIronbow, Blue-Red, High Contrast,
Amber, Hot Metal, Grayscale
Ironbow, Blue-Red,
High Contrast, Grayscale
Level and spanSmooth auto-scaling and manual scaling of level and span
Fast auto toggle between manual
and auto modes
Yes—
Fast auto-rescale in manual modeYes—
Minimum span (in manual mode)2.5 °C (4.5 °F)5 °C (9 °F)
Minimum span (in auto mode)5 °C (9 °F)10 °C (18 °F)
IR-Fusion
Automatically aligned (parallax
corrected) visual and IR blending
Picture-In-Picture (PIP)Three levels of on-screen IR blending
® information
Yes
100 % IR displayed in center of LCD
No IR-Fusion
displayed in center of LCD (AutoBlend)
Full screen infraredThree levels of on-screen IR blending
displayed on LCD (AutoBlend)
Voice annotation60 seconds maximum recording time per
image; reviewable playback on imager
——
100 % IR displayed on LCD
Image capture and data storage
The Ti25 allows user to adjust palette,
blending, level, span,
® mode, emissivity, and reflected
IR-Fusion
background temperature compensation on
——
a captured image before it is stored.
Image capture, review, save
mechanism
One-handed image capture, review, and save capability
Storage mediumSD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images
each with 60 seconds voice annotations (when available), or 3000 basic bitmap (.bmp) images transferrable
to PC via included multi-format USB card reader
File formatsNon-radiometric (.bmp) or fully-radiometric (.is2)
No analysis software required for non-radiometic bitmap (.bmp) files
Memory review Sequential image navigation and review
2 Fluke Corporation Ti25, Ti10 and Ti9 Industrial/Commercial Thermal Imagers
General specifications
Operating temperature-10 °C to +50 °C (14 °F to 122 °F)
Storage temperature-20 °C to +50 °C (-4 °F to 122 °F) without batteries
Relative humidity10 % to 95 % non-condensing
Display9.1 cm (3.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight and clear protective cover
Controls and adjustmentsUser selectable temperature scale (°C/°F)
SoftwareSmartView
BatteriesInternal rechargeable battery pack (included)
Battery lifeThree to four hours continuous use (assumes 50 % brightness of LCD)
Battery charge time2.5 hours to full charge
AC battery chargingAC adapter/charger (110 V ac to 220 V ac, 50/60 Hz) (included), charges battery while imager is operating or turned off, ac mains
AC operation AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz). AC mains adapters included.
Power savingSleep mode activated after five minutes of inactivity, automatic power off after 30 minutes of inactivity
Safety standardsCSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
Electromagnetic compatibility Meets all applicable requirements in EN61326-1:2006
C TickIEC/EN 61326-1
US FCCCFR 47, Part 15 Class B
Vibration0.03 g2/Hz (3.8 grms), IEC 68-2-6
Shock25 g, IEC 68-2-29
Drop2 meter (6.5 feet)
Size (H x W x L)26.7 cm x 12.7 cm x 15.2 cm (10.5 in x 5.0 in x 6.0 in)
Weight (battery included)1.2 kg (2.6 lb)
Enclosure ratingIP54 (protected against dust, limited ingress; protection against water spray from all directions)
WarrantyTwo-years (standard)
Recommended calibration cycle Two-years (assumes normal operation and normal wear)
Supported LanguagesCzech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish,
Language selection
Time/Date set
Emissivity selection (Ti25 only)
Reflected background temperature compensation (Ti25 only)
User selectable hot spot and cold spot, and center point on the image (Ti25 only) (other custom markers and shapes in SmartView
software)
User selectable backlight: “Full Bright” or “Auto”
Thermal imager, ac power supply/battery charger (including mains adapters); SD memory card;
multi-format USB memory card reader for downloading images into your computer; SmartView®
software with free software upgrades for life; rugged, hard carrying case; soft transport bag;
adjustable hand strap; printed users manual; warranty registration card.
Optional accessories
TI-CAR-CHARGER Thermal Imager Vehicle Charger
TI-VISOR Thermal Imager Visor
BOOK-ITP Introduction to Thermography Principles Book
TI-TRIPOD Tripod Mounting Base Accessory
3 Fluke Corporation Ti25, Ti10 and Ti9 Industrial/Commercial Thermal Imagers
Fluke. Not just infrared.
Infrared you can use.
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com