Fluke Ti9 Specifications

Fluke Industrial/Commercial
Thermal Imagers
Models: Ti25, Ti10 and Ti9
High performance thermal imagers have never been this affordable. This rugged. Or, this easy to use … until now.
The perfect tools to add to your problem solving arsenal. Built for tough work environments, these high-performance, fully
Ti25
Ti10
Ti9
Industrial, mechanical, electromechanical and general building maintenance.
radiometric imagers are ideal for troubleshooting electrical installations, electro-mechanical equipment, process equipment, HVAC/R equipment and others.
The Fluke Ti10 and Ti25 thermal imagers come with enhanced problem detection and analysis capabilities with IR-Fusion® Technology. Simply scroll through the different viewing modes quickly to better identify trouble areas in Full IR thermal, picture­in-picture, or automatic blend visual and thermal images.
Optimized for field use in harsh work environments
– Engineered and tested to withstand a 2 m (6.5 ft) drop – Withstands dust and water—tested to an IP54 rating.
Delivers the clear, crisp images needed to find problems fast.
Identify even small temperature differences that could indicate
problems with excellent thermal sensitivity (NETD).
Intuitive, three-button menu is easy to use—simply navigate with the push of a thumb.
No need to carry pen and paper—record findings by speaking into the camera. Voice comments are saved along with individual images for future reference (Ti25 only)
Fluke. Not just infrared, infrared you can use.
Technical Data
®
Process, refractory insulation, tank and vessel levels, steam systems and traps, pipes and valves, etc.
Electrical, unbalanced loads, overloaded systems, wiring mistakes or component failure, etc.
Patented Fluke IR-Fusion® Technology
More than picture in picture
Infrared images alone can be difficult to under­stand, which is why Fluke pioneered IR-Fusion, a revolutionary marriage of visible and infrared images never before seen in commercial or industrial thermal imagers. Automatically capturing a visible image with every infrared image allows to you always know exactly what you’re looking at.
Not all fusion is created equal
Don’t be fooled by imitators. No other manufacturer can boast on-camera blending. Compare the images. Only Fluke has mastered the ability to create the industry’s only transparent, perfectly blended and aligned visible and infrared images.
Fluke Competitor
Detailed specifications
Temperature
Ti25 Ti10 Ti9
Temperature measurement range (not calibrated below -10 °C)
Temperature measurement accuracy
-20 °C to +350 °C (-4 °F to +662 °F) -20 °C to +250 °C (-4 °F to +482 °F) -20 °C to +250 °C (-4 °F to +482 °F)
± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
± 5 °C or 5 % (at 25 °C nominal,
whichever is greater) On-screen emissivity correction Yes, and in software In software only On-screen reflected background
temperature compensation
Yes, and in software In software only
Imaging performance
Image capture frequency 9 Hz refresh rate Detector type 160 X 120 Focal Plane Array, uncooled microbolometer Thermal sensitivity (NETD) ≤ 0.09 °C at 30 °C target temp. (90 mK) ≤ 0.13 °C at 30 °C target temp. (130 mK) ≤ 0.20 °C at 30 °C target temp. (200 mK) Visual (visible light) camera Industrial performance 1.3 megapixels Minimum (visible light)
46 cm (approx. 18 in)
No visible camera focus distance Infrared field of view 23 ° x 17 ° Spatial resolution (IFOV) 2.5 mRad Minimum infrared focus distance 15 cm (approx. 6 in) Focus mechanism Manual, one-handed Smart Focus capability
Image presentation
Palettes Standard Ironbow, Blue-Red, High Contrast,
Amber, Hot Metal, Grayscale
Ironbow, Blue-Red,
High Contrast, Grayscale Level and span Smooth auto-scaling and manual scaling of level and span Fast auto toggle between manual
and auto modes
Yes
Fast auto-rescale in manual mode Yes — Minimum span (in manual mode) 2.5 °C (4.5 °F) 5 °C (9 °F) Minimum span (in auto mode) 5 °C (9 °F) 10 °C (18 °F)
IR-Fusion
Automatically aligned (parallax corrected) visual and IR blending
Picture-In-Picture (PIP) Three levels of on-screen IR blending
® information
Yes
100 % IR displayed in center of LCD
No IR-Fusion
displayed in center of LCD (AutoBlend)
Full screen infrared Three levels of on-screen IR blending
displayed on LCD (AutoBlend)
Voice annotation 60 seconds maximum recording time per
image; reviewable playback on imager
100 % IR displayed on LCD
Image capture and data storage
The Ti25 allows user to adjust palette,
blending, level, span,
® mode, emissivity, and reflected
IR-Fusion background temperature compensation on
a captured image before it is stored.
Image capture, review, save mechanism
One-handed image capture, review, and save capability
Storage medium SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images
each with 60 seconds voice annotations (when available), or 3000 basic bitmap (.bmp) images transferrable
to PC via included multi-format USB card reader
File formats Non-radiometric (.bmp) or fully-radiometric (.is2)
No analysis software required for non-radiometic bitmap (.bmp) files
Export file formats w/SmartView software
®
BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Memory review Sequential image navigation and review
2 Fluke Corporation Ti25, Ti10 and Ti9 Industrial/Commercial Thermal Imagers
Loading...