Fluke Ti40FT, Ti45FT Catalog Page

Thermal Imaging
Fluke Ti40FT and Ti45FT IR FlexCam® Thermal Imagers with IR-Fusion® Technology
The versatile choice for maintenance and production engineers and technicians
The Fluke Ti4x models feature everything needed for virtually every thermography task. With a 160 x 120 detector and a temperature sensitivity down to 0.08°C (80mK) (NETD) they deliver high resolution images where even the smallest temperature differences can be seen. The units are extremely easy to use through the Windows® CE menu structure and offer an extended troubleshooting feature set to allow on the spot analysis in the field.
The FT models feature the innovative IR­Fusion® technology. IR-Fusion captures a visible light image in addition to the infrared image and takes the mystery out of IR image analysis. It helps to better identify and report suspect components and enable the repair to be done right the first time. To find out more select IR-Fusion on the side navigation of this page.
Typical applications:
Predictive maintenance – Identify
electrical and mechanical problems before they cause failure
Industrial maintenance – Check
whether repairs have been performed successfully
Quality control – Examine prototypes
and refine thermal management designs
Process monitoring – Real-time
observation to ensure efficient and safe operation
Thermal Imaging
Fluke Ti40FT and Ti45FT IR FlexCam® Thermal Imagers with IR-Fusion® Technology
See exactly what you are viewing
Fluke IR-Fusion® technology links a real world visual image with a thermal image. It merges the two images into one, with the possibility to blend between the two images or create picture-in-picture combinations. Alarm limits can be superimposed over the visible light image to exactly pinpoint the components exceeding a specified temperature limit. Both the visual images and thermal images are available for use in reports. This speeds up documentation by reducing the need to look for individual images taken with a separate digital camera. IR Fusion helps to better identify and report suspect components and enable the repair to be done right the first time.
Large, sharp thermal images Thanks to the largest display (five-inch) available on this type of thermal imager in combination with low-noise VOx sensors, the Fluke IR FlexCam units produce exceptionally high-quality images making even the smallest temperature differences visible. This is comparable with images normally only obtained on far more expensive instruments.
A sharp image in every situation The innovative 180 ° articulating lens makes it possible to view and capture images in areas with poor accessibility. The display remains clearly visible while viewing over high objects, under a machine or around immoveable obstructions. The SmartFocus wheel simplifies getting a stable and sharp image. No need to take your hand off the instrument to turn a focus ring.
Make anomalies visible Thanks to built-in functions like AutoCapture, the IR FlexCam Thermal Imagers help to troubleshoot difficult problems. The instrument is easily set up to automatically capture only those images where a temperature limit is exceeded. This way, difficult to find intermittent problems can be captured and analyzed quicker by concentrating only on the images containing the anomalies.
Analysis and reporting comes standard The SmartView™ software (supplied with the unit) includes a complete range of infrared image viewing, analysis, annotation and reporting tools. It even allows for customized reports to accommodate specific company work processes or requirements like multiple image reporting and comparisons. To find out more select SmartView on the side navigation of this page.
Radiometric measurement – the ‘data behind the picture’ Fully radiometric thermal imagers capture and store calibrated temperature data for the matrix of thousands of points that make up a thermal image. This makes it possible to perform detailed analysis and change key parameters like emissivity or temperature range either in the field on the camera or in the office using the PC software.
• High resolution, low noise VOx detector for high quality images 160 x 120
Ti45FT Ti40FT
Temperature range to cover broad industrial applications -20 to + 600 ° C (-4 to 1112 °F)
High temperature option
High thermal sensitivity for viewing even the smallest temperature differences
180º articulating flexible lens to view images in every situation • Choice of 3 interchangeable lenses to cover every application • Large 5" high contrast color LCD for a clear picture independent of lighting
conditions
1200 ºC (2192
ºF)
0.08 ºC (80 mK)
0.09 ºC (90
MK)
Fully radiometric for detailed temperature analysis and tracking • SmartFocus for best image quality and accurate temperature measurements • Windows® CE based menu structure for ease of use • Personalized instrument set-up for multiple use • CompactFlash memory cards to store over 1000 IR images plus fully
radiometric temperature data SmartView reporting and analysis software included • AutoCapture for making intermittent problems visible • On-board analysis functions • User defined text annotations for simplified reporting • Built-in visible light (digital) camera
IR/Visible Alarm function
Laser pointer for easy targeting • Flash and torch light for high quality images in dark environments
Fluke Ti5xFT and
®
Ti4xFT FlexCam Thermal Imagers
The experts’ choice for problem solving and preventive/predictive maintenance
Technical Data
Features
High resolution, low noise VOx detector for high quality images
Temperature range to cover broad industrial applications
High temperature option
High thermal sensitivity for viewing even the smallest temperature differences
180 ° articulating flexible lens to view images in every situation
Choice of 3 interchangeable lenses to cover every application*
Large 5 inch high contrast color LCD for a clear picture independent of lighting conditions
Fully radiometric for detailed temperature analysis and tracking
SmartFocus for best image quality and accurate temperature measurements
Windows CE based menu structure for ease of use
Personalized instrument set-up for multiple person use
CompactFlash memory cards to store over 1000 IR images plus fully radiometric temperature data
SmartView™ reporting and analysis software included
AutoCapture for making intermittent problems visible
On-board analysis functions
User defined text annotations for simplified reporting
Built-in visible (visual) light camera
IR-Fusion blending thermal and visible light images
IR/Visible Alarm function
Laser pointer for easy targeting
Flash and torch light for high quality images in dark environments
*10 mm and 54 mm lenses are optional and are only available at time of initial order.
Ti55FT Ti50FT Ti45FT Ti40FT
320 x 240 160 x 120
-20 °C to
+600 °C (-4 °F
to 1112 °F)
0.05 °C at
30 °C (50 mK)
-20 °C to
+350 °C (-4 °F
to 662 °F)
0.07 °C at
30 °C (70 mK)
+600 °C (-4 °F
-20 °C to
to 1112 °F)
1200 °C
(2192 °F)
0.08 °C at
30 ° C (80 mK)
-20 °C to
+350 °C (-4 °F
to 662 °F)
0.09 °C at
30 ° C (90 mK)
The Fluke Ti5xFT and Ti4xFT models feature everything needed for virtually any thermography task. All Fluke FlexCam Thermal Imagers come standard with the patent-pending Fluke
®
IR-Fusion
Technology fusing visual (visible light) images with infrared images. SmartView™ IR analysis and reporting software is included with each purchase along with free software upgrades for the life of your product. The Ti4xFT models feature 160 x 120 detectors and temperature sensitivity (NETD) down to 0.08 °C (80 mK) in the higher end model. The Ti5xFT models feature 320 x 240 detectors and temperature sensitivity (NETD) down to 0.05 °C (50 mK) in the higher end model. Choose Fluke FlexCam Thermal Imagers when you need industry leading thermal sensitivity for high resolution, ultra high-quality images.
Typical applications:
Troubleshooting—Pinpointing the location of
specific problems in equipment and systems.
Preventive/predictive maintenance
Identify electrical and mechanical problems before they cause failure.
Industrial maintenance—Check whether
repairs have been performed correctly.
Process monitoring—Real-time observa-
tion to ensure efficient and safe operations.
Quality control—Examine prototypes and
refine thermal management designs.
Research and development—Quantify
heat patterns to improve product designs (Ti5XFT models).
Electronic design—Circuit board analysis
(Ti5XFT models).
Detailed specifications
Detailed Specifications
Fluke Ti55FT Fluke Ti50FT Fluke Ti45FT Fluke Ti40FT
Imaging performance
Field of view (FOV)* 23° horizontal x 17° vertical Spatial resolution (IFOV)* 1.30 mrad 2.60 mrad Min focus distance* 0.15 m (5.9 in) Thermal sensitivity (NETD) 0.05 °C at 30 °C (50 mK) 0.07 °C at 30 °C (70 mK) 0.08 °C at 30 °C (80mK) 0.09 °C at 30 °C (90mK) Detector data acquisition/
image frequency Focus SmartFocus; one finger continuous focus (manual) IR digital zoom 2x, 4x, 8x 2x 2x Detector type 320 x 240 Focal Plane Array, Vanadium Oxide (VOx)
Spectral band 8 µm to 14 µm Digital image enhancement Automatic full time enhanced On camera operating
modes
Visible light camera 1280 x 1024 pixels, full color Visible light digital zoom 2x, 4x 2x 2x
Temperature measurement
Calibrated temperature range
Optional—High temperature Up to 1200 °C (2192 °F)
Accuracy ± 2 °C or 2 % (whichever is greater) Measurement modes Centerpoint, center box
Emissivity correction 0.1 to 1.0 (0.01 increments)
Image presentation
Digital display 13 cm (5 in) diagonal large high-resolution digital display
LCD backlight Sunlight readable color LCD Video output RS170 EIA/NTSC or CCIR/PAL composite video Palettes Grayscale, grayscale inverted, blue red, high contrast, hot metal, ironbow, amber, amber inverted
Optical lenses
54 mm telephoto lens High precision Germanium lens
Full thermal, full visual light or merged
-20 °C to 600 °C (-4 °F to 1112 °F) in three ranges
Range one =-20 °C to 100 °C (-4 °F to 212 °F)
Range two = -20 °C to 350 °C (32 °F to 662 °F)
Range three = 250 °C to 600 °C (482 °F to 1112 °F)
(area min/max, average), moveable spots/boxes, user defined field/text annotations, automatic hot and cold point detection, visible color alarm above and below
Spatial resolution (IFOV): 0.47 mrad Spatial resolution (IFOV): 0.94 mrad
60 Hz/60 Hz 30 Hz/30 Hz
Uncooled Microbolometer
thermal-visual images.
Picture-in-Picture
-20 °C to 350 °C (-4 °F to 662 °F) in two ranges
Range one = -20 °C to 100 °C (-4 °F to 212 °F)
Range two = -20 °C to 350 °C (32 °F to 662 °F)
Centerpoint, center box (area min/max, average)
Field of view (FOV): 9° horizontal x 6° vertical
Min focus distance: 0.6 m (1.97 ft)
160 x 120 Focal Plane Array, Vanadium Oxide (VOx)
Uncooled Microbolometer
Full thermal, full visual light or merged thermal-visual
images. Picture-in-Picture
-20 °C to 600 °C (-4 °F to 1112 °F) in three ranges
Range one = -20 °C to 100 °C (-4 °F to 212 °F)
Range two = -20 °C to 350 °C (32 °F to 662 °F)
Range three = 250 °C to 600 °C (482 °F to 1112 °F)
Range 4 = 500 °C to
1200 °C (932 °F to 2192
°F)
Centerpoint, center box (area min/max, average), moveable spots/boxes, user defined field/text annotations, automatic hot and cold point detection, visible color alarm above and below
-20 °C to 350 °C (-4 °F to 662 °F) in two ranges
Range one = -20 °C to 100 °C (-4 °F to 212 °F)
Range two = -20 °C to 350 °C (32 °F to 662 °F)
Centerpoint, center box (area min/max, average)
2 Fluke Corporation Ti5XFT and Ti4XFT Thermal Imagers with IR-Fusion
General specifications
Ordering information
FLK-Ti40FT-20 IR FlexCam Thermal Imager with IR-Fusion FLK-Ti45FT-20 IR FlexCam Thermal Imager with IR-Fusion FLK-Ti50FT-20 IR FlexCam Thermal Imager with IR-Fusion FLK-Ti55FT-20 IR FlexCam Thermal Imager with IR-Fusion
Included with product
Heavy duty carrying case, 2 rechargeable battery packs, battery charger, ac adapter (for Ti45FT and Ti55FT only), video cable, 512 MB compact flash card, compact flash card reader and USB cable, PCMCIA compact flash card reader, neck strap, printed getting started guide, SmartView reporting and analysis, software on CD, complete user manual on CD
Fluke Ti55FT Fluke Ti50FT Fluke Ti45FT Fluke Ti40FT
Optical lenses (continued)
10.5 mm wide angle lens High precision Germanium lens
Field of view (FOV): 42° horizontal x 32° vertical
Spatial resolution (IFOV): 2.45 mrad Spatial resolution (IFOV): 4.9 mrad
Min focus distance: 0.3 m (0.98 ft)
Image and data storage
Storage medium Compact flash card stores over 1000 IR images (512 MB card standard) File formats supported 14 bit measurement data included. Exportable Images: bmp, gif, jpg, png, tiff;
Data formats: comma separated (csv), tab separated (txt).
Interface and software
Interface Compact flash card reader included Software SmartView; Full analysis and reporting software included
Laser
Classification Class II Laser targeting Laser dot visible on screen when blending thermal and visible image
Controls and adjustments
Set-up controls Date/time, temperature units C/F, language, scale, LCD intensity (high/normal/low) Image controls Level, span, auto adjust (continuous/manual) On-screen indicators Battery status, target emissivity, background temperature and realtime clock
Power
Battery type Li-Ion smart battery, rechargeable, field-replaceable (two included) Battery operating time Two hours continuous operation (per battery) Battery charging Two bay intelligent charger powered via ac outlet Continuous ac operation AC adapter 110/220 V ac,
50/60 Hz
AC adapter 110/220 V ac,
50/60 Hz
Power saving Automatic shutdown and sleep modes (user specified)
Environmental and mechanical design
Operating temperature -10 °C to +50 °C (14 °F to 122 °F) Storage temperature -40 °C to +70 °C (-40 °F to 158 °F) Relative humidity Operating and storage 10 % to 95 %, non-condensing Water and dust resistant IP54 Weight (including batteries) 1.95 kg (4.3 lb) Camera size (H x W x D) 162 mm x 262 mm x 101 mm (6.5 in x 10.5 in x 4.0 in)
Other
Warranty Two-years
*Standard 20 mm Germanium lens
3 Fluke Corporation Ti5XFT and Ti4XFT Thermal Imagers with IR-Fusion
Fluke. Keeping your world up and running.
®
Loading...