Voltage Indicator
®
Continuity & Resistance
Display HOLD
T5-600/T5-1000
Electrical Tester
Instruction Card
Warning
Read the T5-600/T5-1000 Safety Sheet before
using this tester.
Před použitím této zkoušečky si přečtete
bezpečnostní informace k modelu
T5-600/T5-1000.
Przed użyciem próbnika należy przeczytać
instrukcje dotyczące bezpieczeństwa
zamieszczone w dokumencie T5-600/T5-1000.
Перед использованием данного
измерительного прибора прочтите
Инструкции по технике безопасности
T5-600/T5-1000.
Bu test cihazını kullanmadan önce
T5-600/T5-1000 Güvenlik Broşürü'nü okuyun.
V
T5-600 max: 600 V CAT III
T5-1000 max: 1000 V CAT III, 600 V CAT IV
HOLD
AC/DC
V
Automatic
Selection
V
45 Hz - 66 Hz
T5-600 max: 600 V rms CAT III
T5-1000 max: 1000 V rms CAT III, 600 V rms CAT IV
Open
A
0.5"(12.9 mm)
maximum
Short
1000 Ω
Range
Less than
25 Ω
Greater than
400 Ω
AC
A
AC
HOLD
Tactile
Barrier
HOLD
1
HOLD
2
HOLD
December 2001, Rev.3, 1/13
(Czech, Polish, Russian, Turkish, Arabic)
2001 - 2013 Fluke Corporation. All rights reserved.
AC/DC
V
Automatic
Selection
HOLD
AC
HOLD
OK
Sensor
OK
Zone
OK
1 Wire
only
3
Auto Off
LO
45 min
OFF
Warning
Disconnect test leads from power source
before opening battery door.
Před otevřením krytu baterie odpojte od
zdroje napájení měřicí přívody.
Przed otwarciem wnęki baterii należy
odłączyć przewody testowe od źródła
zasilania.
Перед тем как открыть крышку батарейного
отсека, отсоедините измерительные провода.
Pil kapağını açmadan önce test iletkenlerinin
güç kaynağıyla bağlantısını kesin.
Do not
+
2 AA
+
+
overtighten
screw
+
Specifications
Specifications subject to change without notice.
Calibration 1-year calibration cycle
Temperature
Operating:
Storage:
Altitude
Operating:
Storage:
Relative
Humidity
Battery Type
and Life
RF Field
Specification
Enclosure
Rating
Temperature
coefficient
Accuracy
Safety ......................... IEC 61010-1: Pollution Degree 2
Electromagnetic
Environment ................ IEC 61326-1: Portable
-10 °C to +50 °C (14 °F to 122 °F)
-30 °C to +60 °C (-22 °F to +140 °F)
2000 m (6562 ft)
10,000 m (32808 ft)
0 % to 95 %, 5 °C to 30 °C
(41
°F to 86 °F); 0 % to 75 %,
°C to 40 °C
30
(86
°F to 104 °F); 0 % to 45 %,
40
°C to 50 °C
(104
°F to 122 °F)
AA (2); 360 hours continuous with
alkaline; 125 hours continuous with
zinc chloride
0.5 % full scale + (specified accuracy)
at 3 V / m
IP 52 per IEC 60529, no vacuum
applied
0.1 x (specified accuracy) / °C for <18
°C or >28 °C (< 64.4 °F or > 82.4 °F)
± ( [ % of reading] + [number of least
significant digits] )
Accuracy is specified for 1 year after
calibration, at 18
(64
°F to 82 °F) with relative humidity
to 90 %. AC conversions are accoupled, average responding, and
calibrated to the rms value of a sine
wave input.
°C to 28 °C
Function
T5-600
Range
(600 V
CAT III)
600 V
600 V 1000 V 1 V ±(1 % + 1 digit)
100.0 A 100.0 A
1000 Ω 1000 Ω 1 Ω ±(1 % + 2 digits)
rms
T5-1000
Range
(1000 V
CAT III)
1000 V
rms
Resolution
1 V ±(1.5 % + 2 digits)
0.1 A
Replacement Parts
Test Lead Assembly.
Replace only with Fluke double-insulated
See "Accessories" for available
leads (
)
probes.
rooD yrettaB
wercS rooD yrettaB
Use only specified replacement parts.
Accessories
H
5 Belt Holster
TP1 Probe Set, Flat-Blade
AC285 SureGrip™ Alligator Clips
AC220 SureGrip™ Alligator Clips
Service Information Sheet, PN 686953
To contact Fluke, call:
USA: 1-800-44-FLUKE (1-800-443-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-67143114
Singapore: +65-738-5655
Anywhere in the world: +1-425-446-5500
Visit Fluke's Web site at www.fluke.com.
Accuracy
45 Hz - 66 Hz
±(3 % + 3 digits)
45 Hz - 66 Hz
PN 648029
PN 2091779
PN 8758161