T5-600/T5-1000
Electrical Tester
Instruction Card
Warning
Read the T5-600/T5-1000 Safety Sheet before using this tester.
Před použitím této zkoušečky si přečtete bezpečnostní informace k modelu
T5-600/T5-1000.
Przed użyciem próbnika należy przeczytać instrukcje dotyczące bezpieczeństwa zamieszczone w dokumencie T5-600/T5-1000.
Перед использованием данного измерительного прибора прочтите Инструкции по технике безопасности
T5-600/T5-1000.
Bu test cihazını kullanmadan önce T5-600/T5-1000 Güvenlik Broşürü'nü okuyun.
T5-600 max: 600 V CAT III T5-1000 max: 1000 V CAT III, 600 V CAT IV
HOLD
AC/DC
V
Automatic
Selection
45 Hz - 66 Hz T5-600 max: 600 V rms CAT III T5-1000 max: 1000 V rms CAT III, 600 V rms CAT IV
Open
A
0.5"(12.9 mm) maximum
Short
1000 Range
Less than 25
Greater than 400
AC
A
AC
HOLD
Tactile Barrier
HOLD
1
HOLD
2
HOLD
December 2001, Rev.3, 1/13
(Czech, Polish, Russian, Turkish, Arabic)
2001 - 2013 Fluke Corporation. All rights reserved.
AC/DC
V
Automatic
Selection
HOLD
AC
HOLD
OK
Sensor
OK
Zone
OK
1 Wire
only
3
Auto Off
LO
45 min
OFF
Warning
Disconnect test leads from power source before opening battery door.
Před otevřením krytu baterie odpojte od
zdroje napájení měřicí přívody.
Przed otwarciem wnęki baterii należy
odłączyć przewody testowe od źródła zasilania.
Перед тем как открыть крышку батарейного отсека, отсоедините измерительные провода.
Pil kapağını açmadan önce test iletkenlerinin güç kaynağıyla bağlantısını kesin.
Do not
+
2 AA
+
+
overtighten screw
+
Specifications
Specifications subject to change without notice.
Calibration 1-year calibration cycle
Temperature Operating: Storage:
Altitude Operating: Storage:
Relative Humidity
Battery Type and Life
RF Field Specification
Enclosure Rating
Temperature coefficient
Accuracy
Safety ......................... IEC 61010-1: Pollution Degree 2
Electromagnetic
Environment ................ IEC 61326-1: Portable
-10 °C to +50 °C (14 °F to 122 °F)
-30 °C to +60 °C (-22 °F to +140 °F)
2000 m (6562 ft) 10,000 m (32808 ft)
0 % to 95 %, 5 °C to 30 °C (41
°F to 86 °F); 0 % to 75 %,
°C to 40 °C
30 (86
°F to 104 °F); 0 % to 45 %,
40
°C to 50 °C
(104
°F to 122 °F)
AA (2); 360 hours continuous with alkaline; 125 hours continuous with zinc chloride
0.5 % full scale + (specified accuracy) at 3 V / m
IP 52 per IEC 60529, no vacuum applied
0.1 x (specified accuracy) / °C for <18
°C or >28 °C (< 64.4 °F or > 82.4 °F) ± ( [ % of reading] + [number of least
significant digits] ) Accuracy is specified for 1 year after calibration, at 18 (64
°F to 82 °F) with relative humidity
to 90 %. AC conversions are ac­coupled, average responding, and calibrated to the rms value of a sine wave input.
°C to 28 °C
Function
T5-600 Range
(600 V
CAT III)
600 V
600 V 1000 V 1 V ±(1 % + 1 digit)
100.0 A 100.0 A
1000 1000 1 ±(1 % + 2 digits)
rms
T5-1000
Range (1000 V CAT III)
1000 V
rms
Reso­lution
1 V ±(1.5 % + 2 digits)
0.1 A
Replacement Parts
Test Lead Assembly. Replace only with Fluke double-insulated
See "Accessories" for available
leads (
)
probes.
rooD yrettaB
wercS rooD yrettaB
Use only specified replacement parts.
Accessories
H
5 Belt Holster
TP1 Probe Set, Flat-Blade AC285 SureGrip Alligator Clips AC220 SureGrip Alligator Clips Service Information Sheet, PN 686953
To contact Fluke, call:
USA: 1-800-44-FLUKE (1-800-443-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200
Japan: +81-67143114 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500
Visit Fluke's Web site at www.fluke.com.
Accuracy
45 Hz - 66 Hz
±(3 % + 3 digits)
45 Hz - 66 Hz
PN 648029
PN 2091779
PN 8758161
Loading...