Fluke Fluke FEV100/TY1 KIT2 Manual

Test Equipment Depot - 800.517.8431
TECHNICAL DATA
- 5 Commonwealth Ave, MA 01801 - TestEquipmentDepot.com
Fluke eMobility Tools Kit with FEV100 Test Adapter, 125B ScopeMeter®, 87V Multimeter and Test Leads
Key features
Test charging states of EVSE with CP state simulation with the 12B ScopeMeter®. Verify charging voltage and maximum available current using the 87V multimeter and TL224 test leads. Check protective earth for correct wiring and functioning with the PE pre-test feature. Perform GFCI troubleshooting of EVSE and verify operation within safety standards.
Product overview: Fluke eMobility Tools Kit with FEV100 Test Adapter, 125B ScopeMeter®, 87V Multimeter and Test Leads
Test the safety and performance of a type 1, level 1 or level 2 electric vehicle ac charging stations (EVSEs) with the Fluke FEV100, 87V + 125B ScopeMeter® kit. This kit includes the FEV100 test adapter to simulates the presence of an electrical vehicle. When connected to the test adapter, the 87V multimeter will allow you to monitor the output voltage and maximum charging current of the station. Verify EVSE charging states (vehicle simulation) by connecting the 125B ScopeMeter® to measure the control pilot signal output. With this kit, it's easy to verify an EV charging station is working properly after install and during periodic maintenance, or troubleshoot an EVSE if it is not delivering the appropriate charge. SAE J1772 compliant to North American standards.
EVSE installation safety and performance checks
PE PRE-TEST: Grounding system pre-test verifies that there is no presence of dangerous voltage at the ground terminal󰾬. GFCI TEST: Ground fault circuit interrupter test verifies the breaker of the EVSE is connected by detecting ground faults󰾬.
PE ERROR: Ground fault simulation indicates an interruption of the ground conductor; the pending charging process is aborted, and new charging processes are prevented. CP ERROR “E”: The standard J1772 defines Error “E” as a state when charging station is disconnected from vehicle, disconnected from utility, there is a loss of utility power or control pilot is short to control pilot reference (ground).
Specifications: Fluke eMobility Tools Kit with FEV100 Test Adapter, 125B ScopeMeter®, 87V Multimeter and Test Leads
Fluke FEV100 Electric Vehicle Charging Station Test Adapter specifications
UL1/N = 120 V, UL2/N = 120 V, UL1/L2 = 208 V, 60 Hz (three-phase system) or
Input voltage
EV connector (EVC-13) SAE J1772 socket, 16 A (type 1, 5P single-phase)
Internal power consumption 2 W max.
Operating temperature -4 °F to 104 °F (-20 °C to 40 °C)
Storage temperature -4 °F to 122 °F (-20 °C to 50 °C)
Operating humidity range 10 % to 85 % relative humidity non-condensing
Storage relative humidity 0 % to 85 % non-condensing
Operating altitude 6561 ft (2000 m) max.
Dimensions (H × W × D) Approx. 8.66 x 4.33 x 1.77 in (220 x 110 × 45 mm) without cable assembly
Weight Approx. 4.4 lb (2 kg)
UL1/N = 120 V, UL2/N = 120 V, UL1/L2 = 240 V, 60 Hz (single-phase system), ±10% voltage fluctuations from nominal
2 Fluke Corporation Fluke eMobil ty Tools K t with FEV100 Test Adapter, 125B ScopeMeter®, 87V Mu timeter and Test Leads
Frequency response - ac coupled (lf roll off)
Without probes and test leads <10 Hz (-3 dB)
With STL120-IV 1:1 shielded test leads <10 Hz (-3 dB)
With VP41 10:1 Probe <10 Hz (-3 dB)
Rise time, excluding probes, test leads
123B <17.5 ns 124B and 125B <8.75 ns
Without probes and test leads 1 MΩ//20 pF
With BB120 1 MΩ//24 pF
Input impedance
With STL120-IV 1:1 shielded test leads 1 MΩ//230 pF
With VP41 10:1 Probe 5 MΩ//15.5 pF
Sensitivity 5 mV to 200 V/div
Analog bandwidth limiter 10 kHz
Display modes A, -A, B, -B
Direct, with test leads, or with VP41
Max. input voltage A and B
Probe
With BB120 600 Vrms
Max. floating voltage, from any terminal to ground
600 Vrms Cat IV, 750 Vrms up to 400Hz
Horizontal
Scope modes Normal, Single, Roll
Equivalent sampling
600 Vrms Cat IV, 750 Vrms maximum voltage.
123B: 20 ns to 500 ns/div,
124B and 125B: 10 ns to 500 ns/div
Ranges (normal)
Real time sampling 1 μs to 5 s/div
Single (real time) 1 μs to 5 s/div
Roll (real time) 1s to 60 s/div
Equivalent sampling (repetitive
Sampling rate (for both channels
signals)
simultaneously)
Real time sampling 1 μs to 60 s/div 40 MS/s
Trigger
Screen update Free run, on trigger
Source A, B
@ DC to 5 MHz 0.5 divisions or 5 mV
@ 40 MHz
Sensitivity A and B
@ 60 MHz
Slope Positive, negative
Up to 4 GS/s
123B: 4 divisions
124B and 125B: 1.5 divisions
123B: N/A
124B and 125B: 4 divisions
4 Fluke Corporation Fluke eMobil ty Tools K t with FEV100 Test Adapter, 125B ScopeMeter®, 87V Mu timeter and Test Leads
Advanced scope functions
Normal
Captures up to 25 ns glitches and displays analog-like persistence waveform
Display modes
Smooth Suppresses noise from a waveform
Glitch off
Envelope
Does not capture glitches between samples
Records and displays the minimum and maximum of waveforms over time
Continuous fully automatic adjustments of amplitude, time base, trigger levels,
Auto set (Connect-and-View™)
trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.
Dual input meter
The accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C.
Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe uncertainty +1%. More than one waveform period must be visible on the screen.
Input A and input B
DC voltage (VDC)
Ranges 500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy ±(0.5% +5 counts)
Common mode rejection (CMRR) >100 dB @ dc, >60 dB @ 50, 60, or 400 Hz
Full scale reading 5000 counts
True-rms voltages (V ac and V ac+dc)
Ranges 500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy for 5% to 100% of range (DC coupled)
Accuracy for 5% to 100% of range (AC or dc coupled)
DC to 60 Hz (V ac+dc) ±(1% +10 counts)
1 Hz to 60 Hz (V ac) ±(1% +10 counts)
60 Hz to 20 kHz ±(2.5% +15 counts)
DC rejection (only VAC) >50 dB
>100 dB @ dc
Common mode rejection (CMRR)
>60 dB @ 50, 60, or 400 Hz
Full scale reading 5000 counts, reading is independent of any signal crest factor.
Peak
Modes Max peak, Min peak, or pk-to-pk
Ranges 500 mV, 5 V, 50 V, 500 V, 2200 V
Accuracy Max peak or Min peak 5% of full scale
Accuracy
Accuracy Peak-to-Peak 10% of full scale
5 Fluke Corporation Fluke eMobil ty Tools K t with FEV100 Test Adapter, 125B ScopeMeter®, 87V Mu timeter and Test Leads
+ 9 hidden pages