Fluke BC7217 Operating Manual

In Case of Difficulty
For service help or to contact Fluke for any reason, call one of the following telephone numbers:
Or, visit Fluke's Web site at www.fluke.com.
-276-6196
*
BC7217-120
BC7217-INTL
®
LIMITED WARRANTY & LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To obtain service during the warranty period, send your defective tester to the nearest Fluke Authorized Service Center with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you.
Fluke Corporation P.O. Box 9090 Everett WA 98206-9090
Fluke Europe B.V. P.O. Box 1186 5602 B.D. Eindhoven The Netherlands
Battery Chargers
Instruction Sheet
Introduction
The Fluke BC7217 Battery Charger charges Fluke BP72XX series Nickel-Cadmium and Nickel-Metal-Hydride battery packs for handheld test tools. The BC7217 consists of a charger base and a power supply.
Connecting the Charger to Line Power
Model BC7217-120, Model BC7217-INTL
Connect the wall adapter to line power within the following range: 90 to 264V ac, 47 to 63 Hz. Plug the barrel connector into the charger dc input jack as shown in Figure 1.
Figure 1. Connecting the Charger to Line Power
PN 691862 September 1998 Rev.1, 3/09 © 1998-2009 Fluke Corporation. All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies.
zq1f.eps
Charging the Battery
Note
Sometimes a new battery needs several charge/discharge cycles before it performs to full capacity.
Before you use a new battery for the first time, charge it fully. Connect the charger to line power and place the battery in the charger as shown in Figure 2. You can leave the battery pack on trickle-charge indefinitely without damage. The charger will not overcharge a battery, even if you reinsert a charged battery.
Nickel-Cadmium Battery To obtain a full charge, charge the battery until the indicator
blinks (approximately 1-1/2 hours).
Nickel-Metal Hydride Battery To obtain a full charge, charge the battery until the indicator
blinks (approximately 2-1/2 hours), then leave it in the charger 3 more hours for a full charge.
Note
When you remove a charged battery from the charger, wait for the blinking indicator to go off before you insert a discharged battery. It takes about 2 seconds for the battery charger to reset.
Charge Mode Indicator
The red indicator light on the side of the charger shows the status of the battery charge cycle as follows:
Off The battery is not inserted, or it is inserted incorrectly, power is
disconnected or not available, or the internal fuse is blown.
Steady on High-current fast charge mode.
Blinking (50% duty cycle) Nickel-Cadmium battery: trickle-charge mode. Nickel-Metal Hydride battery: pulsed charge for the first 3 hours
after blinking starts, then trickle-charge mode.
Blinking (less than 50% duty cycle) Pre-charge delay for proper battery temperature or voltage
conditions.
Internal Fuse
An internal fuse is soldered in place. If the charger indicator does not go on when a battery is installed, this fuse may be blown. The fuse cannot be replaced by the user.
Specifications
Figure 2. Inserting the Battery
When to Charge
Wait until the battery is fully discharged before you charge the battery. The battery will retain its charge longer.
zq2f.eps
BC7217-120, BC-7217-INTL:
Wall Adapter: Input Voltage: 90 to 264 V ac Input Voltage Frequency: 47 to 63 Hz Output Voltage: 15 V dc, 2 A Line power adapters: North America/Japan, Europe, UK, Australia
Safety Approvals: UL, CSA and TUV
Both Models:
Charger Input Voltage: 14 to 20 V dc
DC Power Plug Polarity:
Temperature: Operating: 0 to 40 °C Storage: -20 to 70 °C
Humidity (noncondensing): Operating: 0 to 90% R.H.
Storage: 5 to 95% R.H.
– Ring Negative + Center Positive