FLUKE 705, 715, 787 User Manual

Fluke 705
A large display and simple, pushbutton
interface for ease of use.
Simultaneous mA and % readout for
quick, easy, interpretation of readings.
mA accuracy of 0.02%.
linearity checks. Save time over traditional knob type controls.
"Span Check" for fast confirmation of
zero and span.
Selectable slow ramp, fast ramp, and
step to provide smooth outputs for valve slewing and loop functional tests.
24 volt internal loop supply, so you can
power and read a transmitter at the same time without carrying a DMM.
0 - 20 mA or 4 - 20 mA default start up
modes.
715 Volt/mA Calibrator
Measure loop current (0-20 mA,
4-20 mA) signals with 0.015% accuracy and 0.001 mA resolution
Measure voltage output process signals
from PLCs, transmitters
Source or simulate 24 mA loop current
Source voltage to 100 mV or 10V
24V loop supply with simultaneous
current measurement
Fluke 787
DMM and loop calibrator in one tool
Precision 1000V, 440 mA digital
multimeter
DC current source/loop calibrator
Clear LCD with backlight; 4000 counts
(30 000 counts for DC current)
Externally accessible battery for easy
battery changes
1000V overload protection on V, ohms,
frequency
Meets 1000 volt EN61010-1 CAT III
standards
Min/Max/Average/Hold/Relative modes
705 715 787
0-28 V DC 0-100 mV 0-10 V 1 mV 10 µV 1 mV
0.025% Rdg + 1 LSD 0.02% Rdg + 2 LSD 0.1% Rgd + 1 LSD (VDC)
0-24 mA 0-24 mA 0-1 A 0-30 mA
0.001 mA 0.001 mA 1 mA 0.001 mA
0.02% + 2 LSD 0.015% 0.2%+2 LSD 0.05%+2 LSD
0.025% Rdg + 2 LSD 0.015% + 2 LSD 1000 @ 24 mA 1000 @ 24 mA 500 @ 24 mA
24 V 24 V
Features
Accessories and Ordering Information
Included Accessories:
FLUKE 705: C10 Protective Yellow Holster, TL75 Test Leads, AC70 Test Clips, Instruction Sheet (14 languages). FLUKE 715: C81Y Protective Yellow Holster with Flex-Stand, Test Leads and Alligator Clips, Single 9V alkaline battery, Instruction Sheet (14 languages). FLUKE 787: C81Y Protective Yellow Holster with Flex-Stand, TL75 Safety­Designed Test Lead Set plus AC70A Alligator Clips, one 9V alkaline battery, Users Manual.
Ordering information:
FLUKE 705 Loop Calibrator FLUKE 715 Volt/mA Calibrator FLUKE 787 ProcessMeter
Pub_ID: 10034-eng Rev. 02
1
will over-range to 24 mA
Functions
Voltage measurement
Range 0-1000 V AC or DC Resolution 0.1 mV to 1.0 V Accuracy
Current measurement
Range Resolution Accuracy
Current sourcing
Range 0-20 mA or 4-20 mA
1
0-20 mA or 4-20 mA10-20 mA or 4-20 mA
1
Accuracy 0.05% of span Drive capability 500 @ 24 mA Loop power while
measuring mA N/A Voltage sourcing N/A 0-100 mV or 0-10 V N/A Resistance
measurement N/A N/A to 40 M, 0.2% + 1 LSD Frequency N /A N/A to 19.999 kHz,
0.005% + 1 LSD
Diode test N/A N/A 2.4 V shows
diode voltage drop
Continuity N/A N/A Beeps for
resistance <100 ohms
Display current and % of span Yes mA or % Yes
Auto step, auto ramp Yes No Yes Span Check Yes No No Battery life 18 hours typical, 18 hours typical, 50 hours typical,
at 12 mA at 12 mA 12 hours sourcing 12 mA
Loop Calibrators
Low Cost Calibrator Muscle
®