Fluke 700PRV-1 Instructions

®
Fluke-700PRV-1
Pressure Relief Valve Kit
Instruction Sheet
Introduction
The Fluke-700PRV-1 Pressure Relief Valve is an adjustable pressure relief valve for the Fluke-700HTP-1 Hydraulic Test Pump. The valve provides a pressure relief setting range of 50 to 400 bar (725 to 5,800 psi).
The 700HTP-1 pump can develop pressures up to 690 bar (10,000 psi). Application of too much pressure can damage some pressure instruments. The pressure relief valves in this kit provides a method to protect pressure instruments from accidental overpressure. When the applied pressure reaches the relief setting of the valve, the valve opens and releases hydraulic fluid pressure.
Specifications
Preset Value (±10 %)
2900 psi 200 bar
Relief Setting Range
725 to 5800 psi 50 to 400 bar
Pressure Connection: 1/8-in NPT male thread. This mates with the pressure relief valve port on the 700HTP-1 pump.
Pressure Relief Adjustment Method: Multiturn adjustment screw to set preload on disc springs.
Repeatability of relief setting: ±10 % of nominal setting Material: 303 stainless steel Dimensions (each): 1.52 in by 0.62 in diameter (38 mm by
16 mm diameter) Weight (each): 1.6 oz (46 g)
PN 2811851 April 2007
©2007 Fluke Corporation. All rights reserved. Printed in U.S.A. All product names are trademarks of their respective companies.
Installing a Pressure Relief Valve
1
2
Pressure Release Valve
A
Pressure Release Port
B
Adjusting the Pressure Relief Setting
eum02f.eps
Set the pressure relief by trial and error. The table under Specifications shows the preset pressure relief settings at time of shipment. To set the pressure relief lower, turn the adjustment screw counter-clockwise
(loosen it). To set the pressure relief higher, turn the adjustment screw clockwise
(tighten it).
How to Contact Fluke
To contact Fluke or for service, call one of the following telephone numbers:
USA: 1-888-44-FLUKE (1-888-443-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Or, visit Fluke's Web site at www.fluke.com
.
Limited Warranty & Limitation of Liability
This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To obtain service during the warranty period, send your defective calibrator to the nearest Fluke Authorized Service Center with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you.
Fluke Corporation Fluke Europe B.V. P.O. Box 9090 P.O. Box 1186 Everett, WA 98206-9090 5602 B.D. Eindhoven U.S.A. The Netherlands
Loading...