The Fluke 66 and 68
Infrared Thermometers
Non-contact temperature measurement
The professional’s diagnostic tool
The Fluke 66 and Fluke 68 non-contact thermometers
are the ideal professional diagnostic tools for HVAC
technicians performing room balance checks, electricians
evaluating electrical connections and auto mechanics
diagnosing catalytic converters. This handheld portable
tool enables professionals to research heating and ventilation problems, monitor the status of electrical motors
and electrical panels and diagnose car malfunctions with
ease. They measure surface temperatures, helping to
quickly locate potential blockages or malfunctioning
systems reducing work time and improving performance.
The 60 series thermometers feature:
Laser guided sighting system for easy targeting with
•
1 % accuracy.
12-point data logging.
•
Advanced optics to measure smaller targets at greater
•
distances.
Adjustable emissivity for more accurate temperature
•
measurements.
Selectable MAX, MIN, DIF and AVG functions that
•
display values instantly with Hi/Lo Alarm.
Temperatures up to 760 ºC (1400 ºF) (68, 68IS).
•
Intrinsically Safe model a
•
Optical resolution
The laser sighting system g
right target and indicates the approximate c
measurement area
(D:S = distanc
e to spot using 90 % encircled energy at focal point).
.
vailable (68I
uides measurements to the
*
S).
enter of the
Technical Data
The 68IS*model is available for the noncontact
temperature monitoring needs of potentially explosive
or flammable environments.
*Approved by Factory Mutual Research, a USA organization, for use in hazardous locations.
The 68IS approval does not apply to atmosphere containing coal dust, grain dust, metal dust
or fibers. Check your national and company regulations to determine if this approval is
appropriate for your situation.
S only)
(68I
Specifications
0.9" @
12"
D:S = 30:1
at focal point
S
D
1.2" @
36"
2.5" @
60"
0.8" @
12"
D:S = 50:1
at focal point
S
D
0.7" @
36"
1.7" @
60"
Fluke 66 Fluke 68/68IS
Temperature range -32 to 600 °C -32 to 760 °C
Accuracy -32 to -26 °C (-25 to -15 °F): ±3 °C (±5 °F)
(assumes ambient -26 to -18 °C (-15 to 0 °F): ±2.5 °C (±4 °F)
operating temperature -18 to 23 °C (0 to 73 °F): ±2 °C (±3 °F)
of 23 °C [73 °F]) For targets above 23 °C (73 °F): ±1 % or reading
Repeatability ±0.5 % or ≤ ±1 °C (±2 °F), whichever is greater
Response time ≤ 0.5 second (95 % of reading)
Spectral response 8 to 14 µm
Emissivity Digitally adjustable emissivity
Ambient operating temp. 0 to 50 °C (32 to 120 °F)
Relative humidity 10 to 90 % RH non-condensing,
Storage temperature -20 to 60 °C (-13 to 158 °F) without battery
Dimensions
Weight 320 g (11 oz.)
Power 9 V alkaline or NiCd battery
Batter life (alkaline) 20 hours with laser and backlight on 50 %
Laser sighting (Class II) Offset single point laser point
Typical distance to target 5 m (15 ft.) 8 m (25 ft.)
Distance to Spot (D:S) 30:1 at focus point 50:1 at focus point
MIN, MAX, AVG, DIF
Temperature display
Data logging 12 points
Probe jack
Display hold (7 seconds)
Hi/Low alarm
LCD backlit
Temperature display °C or °F selectable
Display resolution 0.1 °C (0.1 °F)
Hard carrying case
Locking trigger
Tripod mounting 6.35 mm (.25 in.) 20 UNC threading
Warranty 2 years, conditional
y Mutual Research for use in hazardous locations
* Approved by F
actor
(-25 to 1100 °F) (-25 to 1400 °F)
or ±1 °C (±2 °F), whichever is greater
(from 0.1 to 1.0 by 0.01)
at <30 °C (86 °F) ambient
200 x 160 x 55 mm (8 x 6 x 2 in.)
40 hours with laser and backlight off
•
•
•
•
•
•
•
.
*
Ordering information
Fluke 66 Infrared Thermometer
Fluke 68 Infrared Thermometer
Fluke 68IS Infrared Thermometer
Included
Optional accessories:
RTD temperature probe (standard w/68IS)
•
32 ºC to 260 ºC (-25 ºF to 500 ºF)
Non-contact thermometer holster
•
*Included w/68IS
5 ft.) of the
1
e div
ithin 5 m (
ided by 30).
Use the Fluke 66 w
intended target. At greater distances, the
measured area will be larger (approximately
the distanc
ithin 8 m (25 ft
Use the Fluke 68 and 68I
the intended target. At greater distances, the
measured area w
distance divided by 50).
S w
ill be larger (approximately the
Standard F
Factory Mutual Research Intrinsically Safe
•
approval, including prob
eature (68IS only)
e (Intrinsically safe,
Class I Division 1 Groups A, B, C, D Class I,
Zone 0, AEx ia IIC, T4 at 50 ºC when used
with 9V alkaline battery.) Groups A, B, C, D
refers to: Acetylane, Hydrogen, Ethylene
and Propane.
Fluke. Keeping your world
up and running
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
.) of
Fluke Europe B
O Box 1
P
Eindhoven, The Netherlands
or more information call:
F
In the U
In Europe/M-East/Africa +31 (40) 2 675 200 or Fax +31 (40) 2 675 222
In Canada (800) 36-FLUKE or Fax (905) 890-6866
From other c
Web access: http://www.fluke.com
©2005 Fluke Corporation. All rights reserved.
Printed in U
.
.V
D
02 B
86, 56
1
00) 443-5853 or F
. (8
.A
.S
ountries +1 (425) 446-5500 or F
.A. 6/2005 2153543 D-US-N Rev C
.S
.
ax (425) 446-5
16
1
ax +1 (425) 446-5
116