Fluke 59 MAX/59 MAX+
Infrared Thermometer
Fits your budget. Fits your job.
Technical Data
With 65 years of expertise as the leader in the test tools
industry, Fluke has built the 59 MAX and 59 MAX+ IR
thermometers with the precision you need to do your job
accurately and within your budget. Designed to withstand
a 1 meter drop, you can count on these lightweight,
compact IR thermometers to work when you need them.
Product highlights
Precise laser technology for
•
more accurate and repeatable
measurements
Large, easy-to-read backlit
•
LCD display for easy viewing
Small and lightweight design
•
fits easily fits into your tool box
IP40 rated for extra protection
•
10:1 Distance to Spot ratio,
•
59 MAX+ (8:1 Distance to
Spot ratio, 59 MAX)
Displays the minimum, maxi-
•
mum or average temperature,
or the difference between
two measurements
Hi and Lo alarms for rapid
•
display of measurements
outside the limits
Powered by one (1) AA
•
battery
One year warranty
•

Specifications
59 MAX 59 MAX+
Temperature range -30 °C to 350 °C (-22 °F to 662 °F) -30 °C to 500 °C (-22 °F to 932 °F)
Accuracy (Calibration
geometry with
ambient temperature
23 °C ±2 °C)
Response rime (95 %) <500 ms (95 % of reading) < 500 ms (95 % of reading)
Spectral response 8 μm to 14 μm
Emissivity 0.10 to 1.00
Distance to spot ratio 8:1
Display resolution 0.1 °C (0.2 °F)
Repeatability
(% of reading)
General specifications
Power 1 AA IEC LR06 Battery
Batter life 12 hours with laser and backlight on
Weight 220 g (7.76 oz)
Size (156 x 80 x 50) mm (6.14 x 3.15 x 2) inches
Operating temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage temperature -20 °C to +60 °C (-4 °F to 140 °F), (without battery)
Operating humidity 10 % to 90 % RH non-condensing @ 30 °C (86 °F)
Operating altitude 2000 meters above mean sea level
Storage altitude 12,000 meters above mean sea level
Drop test 1 m
Safety specifications
Ingress protection
rating
Vibration and shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
Compliance EN/IEC 61010-1
Laser safety FDA and EN 60825-1 Class II
Electromagnetic
compatibility
≥ 0 °C: ± 2.0 °C or ± 2.0 % of
reading, whichever is
greater
≥ -10 °C to <0 °C: ± 2.0 °C ≥ -10 °C to <0 °C: ± 2.0 °C
< -10 °C: ± 3.0 °C < -10 °C: ± 3.0 °C
≥ 32 °F: ± 4.0 °F or ± 2.0 % of
reading, whichever is
greater
≥ 14 °F to <32 °F: ± 4.0 °F ≥14 °F to <32 °F: ± 4.0 °F
< 14 °F: ± 6.0 °F <14 °F: ± 6.0 °F
(calculated at 90 % energy)
±1.0 % of reading or ±1.0 °C
(±2.0 °F), whichever is greater
IP40 per IEC 60529
61326-1 EN 61326-2
≥ 0 °C: ± 1.5 °C or ± 1.5 % of
reading, whichever is
greater
≥ 32 °F: ± 3.0 °F or ± 1.5 % of
reading, whichever is
greater
10:1
(calculated at 90 % energy)
±0.8 % of reading or ±1.0 °C
(±2.0 °F), whichever is greater
2 Fluke Corporation Fluke 59 MAX/59 MAX+ Infrared Thermometer

Ordering information
Fluke 59 MAX Infrared Thermometer
Fluke 59 MAX+ Infrared Thermometer
Included:
Thermometer, One (1) AA battery,
registration card and user instructions.
3 Fluke Corporation Fluke 59 MAX/59 MAX+ Infrared Thermometer
Fluke. The Most Trusted Tools
in the World.
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2013 Fluke Corporation.
Specifications subject to change without notice.
Printed in U.S.A. 6/2013 6000025A_EN
Modification of this document is not permitted
without written permission from Fluke Corporation.