Fluke 59-MAX Specifications

Page 1
Fluke 59 MAX/59 MAX+
Infrared Thermometer
Fits your budget. Fits your job.
Technical Data
With 65 years of expertise as the leader in the test tools industry, Fluke has built the 59 MAX and 59 MAX+ IR thermometers with the precision you need to do your job accurately and within your budget. Designed to withstand a 1 meter drop, you can count on these lightweight, compact IR thermometers to work when you need them.
Product highlights
Precise laser technology for
more accurate and repeatable measurements
Large, easy-to-read backlit
LCD display for easy viewing
fits easily fits into your tool box
IP40 rated for extra protection
10:1 Distance to Spot ratio,
59 MAX+ (8:1 Distance to Spot ratio, 59 MAX)
Displays the minimum, maxi-
mum or average temperature, or the difference between two measurements
Hi and Lo alarms for rapid
display of measurements outside the limits
Powered by one (1) AA
battery
One year warranty
Page 2
Specifications
59 MAX 59 MAX+
Temperature range -30 °C to 350 °C (-22 °F to 662 °F) -30 °C to 500 °C (-22 °F to 932 °F)
Accuracy (Calibration geometry with ambient temperature 23 °C ±2 °C)
Response rime (95 %) <500 ms (95 % of reading) < 500 ms (95 % of reading)
Spectral response 8 μm to 14 μm
Emissivity 0.10 to 1.00
Distance to spot ratio 8:1
Display resolution 0.1 °C (0.2 °F)
Repeatability (% of reading)
General specifications
Power 1 AA IEC LR06 Battery
Batter life 12 hours with laser and backlight on
Weight 220 g (7.76 oz)
Size (156 x 80 x 50) mm (6.14 x 3.15 x 2) inches
Operating temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage temperature -20 °C to +60 °C (-4 °F to 140 °F), (without battery)
Operating humidity 10 % to 90 % RH non-condensing @ 30 °C (86 °F)
Operating altitude 2000 meters above mean sea level
Storage altitude 12,000 meters above mean sea level
Drop test 1 m
Safety specifications
Ingress protection rating
Vibration and shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
Compliance EN/IEC 61010-1
Laser safety FDA and EN 60825-1 Class II
Electromagnetic compatibility
≥ 0 °C: ± 2.0 °C or ± 2.0 % of
reading, whichever is greater
≥ -10 °C to <0 °C: ± 2.0 °C ≥ -10 °C to <0 °C: ± 2.0 °C
< -10 °C: ± 3.0 °C < -10 °C: ± 3.0 °C
≥ 32 °F: ± 4.0 °F or ± 2.0 % of
reading, whichever is greater
≥ 14 °F to <32 °F: ± 4.0 °F ≥14 °F to <32 °F: ± 4.0 °F
< 14 °F: ± 6.0 °F <14 °F: ± 6.0 °F
(calculated at 90 % energy)
±1.0 % of reading or ±1.0 °C (±2.0 °F), whichever is greater
IP40 per IEC 60529
61326-1 EN 61326-2
≥ 0 °C: ± 1.5 °C or ± 1.5 % of
reading, whichever is greater
≥ 32 °F: ± 3.0 °F or ± 1.5 % of
reading, whichever is greater
10:1 (calculated at 90 % energy)
±0.8 % of reading or ±1.0 °C (±2.0 °F), whichever is greater
2 Fluke Corporation Fluke 59 MAX/59 MAX+ Infrared Thermometer
Page 3
Ordering information
Fluke 59 MAX Infrared Thermometer Fluke 59 MAX+ Infrared Thermometer
Included:
Thermometer, One (1) AA battery, registration card and user instructions.
3 Fluke Corporation Fluke 59 MAX/59 MAX+ Infrared Thermometer
Fluke. The Most Trusted Tools in the World.
Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands
For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com
©2013 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 6/2013 6000025A_EN
Modification of this document is not permitted without written permission from Fluke Corporation.
Loading...