Fluke 568 Data Sheet

The Fluke 568 Ex
Intrinsically Safe
Infrared Thermometer
Intrinsically safe temperature measurements . Anywhere in the world .
Technical Data
The Fluke 568 Ex Intrinsically Safe Infrared Thermometer is the one product you can use in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments anywhere in the world. Whether you work in petroleum, chemical, oil & gas or pharmaceutical environments, the new 568 Ex allows you to carry the most trusted name in test tools into most Ex rated areas all around the globe.
With a straight-forward user interface and soft­key menus, the Fluke 568 Ex makes even complex measurements easy. Quickly navigate and adjust emissivity, save data or turn on and off alarms, with just a few pushes of a button. All in a single intrinsically safe tool certified by major rating bodies from around the world.
Product Highlights
With a rugged, easy-to-use, ergonomic design, the Fluke 568 Ex can stand up to tough industrial, electrical, and mechanical environments.
Meets intrinsically safe certifications in Class I
Div 1 and Div 2 or Zone 1 and 2 hazardous environments from recognized safety agencies around the world
Measure -40 °C to 800 °C (-40 °F to 1472 °F)
Conductive Case for carrying the IR thermometer
safely into hazardous area
Easily access advanced features with the soft-key
buttons and graphical display
Measure small objects from further away, with
a distance-to-spot ratio of 50:1
Compatible with mini-connector K-type thermo-
couple (KTC) probe
Confidently measure a wide variety of surfaces
with the adjustable emissivity feature, including a built-in material table
Capture up to 99 points of data
Confidently troubleshoot equipment with ± 1 %
measurement accuracy
Versatile interface with five languages from which
to choose
Two-year warranty
Specifications
Fluke 568 Ex Infrared Thermometer
Infrared temperature range
Infrared accuracy < 0 °C (32 °F): ± (1.0 °C (± 2.0 °F) + 0.1°/1 °C or °F);
Display resolution 0.1 °C/0.1 °F
Infrared spectral response 8 µm to 14 µm
Infrared response time < 500 ms
Thermocouple Type-K input temperature range
Thermocouple Type-K input accuracy
D:S (distance to measure­ment spot size)
Laser sighting Single-point laser
Minimum spot size 19 mm (0.75 in)
Emissivity adjustment By built-in table of common materials or digitally
Data storage 99 points
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Display Dot matrix with function menus
Backlight Two levels, normal and extra bright for darker
Trigger lock Yes
Switchable Celsius and Fahrenheit
Power 2 AAA/LR03 type-approved Batteries (For a list of
Battery life 4 hours with laser and backlight on; 100 hours with
Operating temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage temperature -20 °C to 60 °C (-4 °F to 140 °F)
Bead thermocouple Type-K range
Bead thermocouple Type-K accuracy
-40 °C to 800 °C (-40 °F to 1472 °F)
≥ 0 °C (32 °F): ± 1 % or ± 1.0 °C (± 2.0 °F), whichever is greater
-270 °C to 1372 °C (-454 °F to 2501 °F)
<-40 °C: ±(1 °C + 0.2 °/1 °C) ≥-40 °C: ±1 % or 1 °C, whichever is greater <-40 °F: ±(2 °F + 0.2 °/1 °F) ≥-40 °F: ±1 % or 2 °F, whichever is greater
50:1
adjustable from 0.10 to 1.00 by 0.01
environments
Yes
type-approved batteries, refer to Product Safety Instructions)
laser and backlight off, at 100 % duty cycle
-40 °C to 260 °C (-40 °F to 500 °F)
± 1.1 °C (2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F), typically within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F)
Ordering information
FLUKE-568 Ex Intrinsically Safe Infrared Thermometer
Included equipment
K-type thermocouple bead probe
Conductive IS hard carrying case
User’s manual
Safety Certifications
Agency Safety rating
ATEX/IECEx
NEC-500/NEC-505
GOST
PCEC
INMETRO
Fluke. The Most Trusted Tools in the World.
Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands
For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com
©2014 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 9/2014 6000203C_EN
Modification of this document is not permitted without written permission from Fluke Corporation.
Zone 1 and 2 IECEx EPS 13.0006X Ex ia IIC T4 Gb 0 °C ≤ Ta ≤ 50 °C EPS 13 ATEX 1.525 X II 2G Ex ia IIC T4 Gb
Class I Division 1 and 2 Class I, Division 1, Groups ABCD T4 Class I, Division 2, Groups ABCD T4 Class I, Zone 1, AEx ia IIC T4 Ex ia IIC T4 0 °C ≤ Ta ≤ 50 °C
Zone 1 and 2 POCC DE. Ex ia IIC T4 Gb X
ОТ 0 °C ДО +50 °C
EPS 13 ATEX 1 525 X II 2G Ex ia IIC T4 Gb 0 °C ≤ Ta ≤ 50 °C
Zone 1 and 2 PCEC Ex ia IIC T4 Gb CE13. EPS 13 ATEX 1 525 X II 2G Ex ia IIC T4 Gb 0 °C ≤ Ta ≤ 50 °C
Zone 1 and 2 IEx 13.0122X Ex ia IIC T4 Gb EPS 13 ATEX 1 525 X II 2G Ex ia IIC T4 Gb 0 °C ≤ Ta ≤ 50 °C