Fluke 117 Data Sheet

Fluke 117
N10140
R
Electrician’s Multimeter
with Non-Contact Voltage
Compact true-rms meter for commercial applications
The Fluke 117 is the ideal meter for demanding settings like commercial buildings, hospitals and schools. The 117 includes integrated non-contact voltage detection to help get the job done faster.
Features include:
VoltAlerttechnology for non-contact voltage detection
AutoVolt automatic ac/dc voltage selection
LoZ: helps prevent false readings due to ghost voltage
Large white LED backlight to work in poorly lit areas
True-rms for accurate measurements on non-linear loads
Measures 10 A (20 A overload for 30 seconds)
Resistance, continuity, frequency and capacitance
Min/Max/Average to record signal fluctuations
Compatible with optional magnetic hanger (ToolPak) for
hands free operation
CAT III 600 V safety rated
Technical Data
Actual size
General specifications
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. The accuracy specifications take the form of: ± ( [ % of reading ] + [ counts ] )
Maximum voltage between any terminal and earth ground
Surge protection 6 kV peak per IEC 61010-1 600 V
Fuse for A input 11 A, 1000 V FAST Fuse
Display Digital: 6,000 counts, updates 4/sec Bar graph 33 segments, updates 32/sec Operating temperature -10 °C to + 50 °C Storage temperature -40 °C to + 60 °C Battery 9 volt Alkaline, NEDA 1604A/
Battery life 400 hours typical, without backlight
600 V
CAT III, Pollution Degree 2
(Fluke PN 803293)
IEC 6LR61
Accuracy specifications
Measurement Range Resolution Accuracy ± ([% of reading] + [counts])
DC millivolts 600.0 mV 0.1 mV 0.5 % + 2
DC volts 6.000 V 0.001 V
0.5 % + 260.00 V 0.01 V
600.0 V 0.1 V
Auto volts 600.0 V 0.1 V 2.0 % + 3 (dc, 45 Hz to 500 Hz)
AC millivolts1 true-rms
AC volts1 true-rms 6.000 V 0.001 V
Continuity 600 Ω 1 Ω Beeper on < 20 Ω off > 250 Ω; detects
Ohms 600.0 Ω 0.1Ω 0.9 % + 2
Diode test 2.000 V 0.001 V 0.9 % + 2
Capacitance 1000 nF 1 nF
Lo-Z capacitance 1 nF to 500 µF 10 % + 2 typical
AC amps true-rms (45 Hz to 500 Hz)
DC amps 6.000 A 0.001 A
Hz (V or A input)299.99 Hz 0.01 Hz
Notes:
1
All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non­zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.
2
Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
2 Fluke Corporation 117 Electrician’s Multimeter with Non-Contact Voltage
600.0 mV 0.1 mV 1.0 % + 3 (dc, 45 Hz to 500 Hz)
60.00 V 0.01 V
600.0 V 0.1 V
Ω 0.001 kΩ
6.000 k
Ω 0.01 kΩ
60.00 k
Ω 0.1 kΩ
600.0 k
Ω 0.001 MΩ
6.000 M
Ω 0.01 MΩ 1.5 % + 2
40.00 M
100.0 µF 0.1 µF
9999 µF 1 µF
100 µF to 1000 µF 1.9 % + 2
> 1000 µF 5 % + 20
6.000 A 0.001 A
10.00 A 0.01 A
20 A overload for 30 seconds max.
10.00 A 0.01 A
20 A overload for 30 seconds max.
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
50.00 kHz 0.01 kHz
4.0 % + 3 (500 Hz to 1 kHz)
2.0 % + 3 (500 Hz to 1 kHz)
1.0 % + 3 (45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
opens or shorts of 500 µs or longer.
0.9 % + 1
1.9 % + 210.00 µF 0.01 µF
1.5 % + 3
1.0 % + 3
0.1 % + 2
Ordering information
Fluke-117 Electrician’s
Multimeter with Non-Contact Voltage
Included
TL75 Test leads, holster, User’s manual and 9 V battery (installed).
Fluke. Keeping your world up and running.
Fluke Corporation PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands
For more information call:
3
In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com
©2006 Fluke Corporation. All rights reserved. Specifications subject to change without notice. Printed in U.S.A. 10/2006 2634028 D-EN-N Rev B