Fluidyne 6600 User Manual

4.5 (2)
Fluidyne 6600 User Manual

Series 6600 : P. D. Flowmeters

For Fuels / Solvents / Chemicals / Lube Oils.

Specifications

Size

: DN 06 / 15 / 20 / 25 / 40 / 50 / 80

Flow Accuracy

: 3.0 - 24000 LPH

Accuracy

: ± 0.5% of reading

Repeatability

: ± 0.1% of reading

Operating Pressure

2

: 10 Kg / Cm Max.

Operating Temperature

: 150 oC

Filter Mesh Size

: 150 Micron SS Mesh Reusable Type

Read Out Option

: a) Self Powered Totaliser

 

b) Rate Indicator Totaliser

 

c) Rate Indicator Totaliser + 4 - 20 mA output

 

d) Rate Indicator Totaliser + RS485 Serial Output

End Connections

: Flange : ANSI / BS / DIN

: Screw : BSP / NPT Female Threads

Material of construction

Wetted Parts : Aluminium / SS 316 / PVC

: Piston : PEEK / PVC

 

Seals : BUNA N / Viton / EPDM / Teflon

Introduction

TYPICAL ACCURACY

TYPICAL PRES.

CHARACRERISTICS

DROP CHARACRERISTICS

Test Fluid : Disel

Test Fluid : Disel

The Fluidyne Positive Displacement Flowmeters are based on the time tested Oscillating Piston design. A single moving component in the assembly ensures extremely reliable operation for long period of operation. Use of state of the art solid state magnetic sensor, ultra low powered electronic sensor provides for all the simplicity of a mechanical P.D. Flowmeter and the reliability of electronic sensing and read outs.

ACCURACY%

 

 

 

 

 

 

 

 

 

 

 

Kg/CmPr.Drop

0.5

 

 

 

 

 

 

 

 

 

 

+0.5

 

 

 

 

 

 

 

 

 

 

0.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

0.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-0.5

 

 

 

 

 

 

 

 

 

 

 

0.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

10

20

30

40

50

60

70

80

90

100

 

0

10

20

30

40

50

60

70

80

90

100

% FLOW RATE

% FLOW RATE

Features

Wide operating flow range of 3.0 to 24000 LPH

Guranteed accuracy of +/- 0.5% of reading

Low pressure drop allows gravity head operation.

Operation at maximum 1500 C temperature possible.

Self powered electronics ensures fit and forget operation.

Choice of weatherproof and flameproof electronic enclosures.

Built in high capacity reusable wire mesh filter.

S.S and Plastics builds to suit corrosive liquids.

S.S. and Plastics builds to suit corrosive liquids.

Size Vs Flowrange Table

Flowmeter Size

Operating Flow Range

NB

LPH

DN06

3-60

DN15

60-600

DN20

150-1500

DN25

240-2400

DN40

600-6000

DN50

1200-12000

DN80

2400-24000

www.fluidyne.co.in

Applications

Meter + Integral

Meter + Integral

W/P Indicator

FLP Indicator

Meter + W/P

 

Meter + FLP

Pulse Transmitter

Pulse Transmitter

 

 

 

 

 

 

 

 

 

 

 

 

Remote W/P Indicator

Remote W/P Indicator

Rate + Totaliser

Rate + Totaliser

 

+ 20 mA Analog Output

 

or Rs485 Serial Output

Fluidyne Control Systems (P) Ltd.

S. No. 79/2,Plot No.12, Near Agarwal Godown, Shivne,

Pune-411 023. India

Tel.: 020-25290504, 25290870 Fax: 020-25292773

E-mail: fluidyne@vsnl.net