Flowline UG01, UG03 Data sheet

EchoPod
Reflective Ultrasonic Multi-Function Liquid Level Transmitter
UG01 & UG03
Application
The general purpose reflective ultrasonic multi-function level transmitter provides continuous level measurement up to 9.8’ (3m) with a 4-20 mA analog signal output and four relays, and is configured via our WebCal software. The non-contact liquid level sensor features our proprietary Reflective Technology™ that delivers reliable level measurement in condensing environments. Each relay can be configured for alarm, automatic fill or empty functions. Select this sensor for small tanks with non-foaming or mildly vaporous media such as chemicals, water, wastewater and oil. Typical applications include day tank, IBC or drum, cooling tower, skid or machine, process tank and waste sumps.
Features
Offered in 1.5m (4.9’) and 3m (9.8’) measurement ranges
Fail-safe diagnostics with selectable relay and signal outputs
Narrow 2” (5cm) beam width for applications with limited space
Corrosion resistant PVDF transducer and compact PP enclosure
Short 1.5” (3.8cm) dead band maximizes tank filling capacity
Automatic temperature compensation from -40º to 80º C.
Four programmable relays with embedded level control logic
• 1 pump or valve with 3 alarms
• 2 pumps lead-lag with 2 alarms
• 2 pumps duplexing with 2 alarms
• 4 independent switch point alarms
Reflective Technology
© 2019 Flowline | 10500 Humbolt Street, Los Alamitos, CA 90720 USA p 562.598.3015 f 562.431.8507 w flowline.com DS310125 REV A1
Horizontal Transducer
Signal Attenuation
Reflective Transducer
Patent
Pending
Reliable Measurement
EchoPod
Reflective Ultrasonic Multi-Function Liquid Level Transmitter
UG01 & UG03
DimensionsSpecifications
Range:
Accuracy:
Resolution:
Dead band:
Beam width:
Configuration:
Memory:
Supply voltage:
Max.consumption:
Loop resistance:
Signal output:
Signal invert:
Signal fail-safe:
Contact type:
Contact rating:
Contact fail-safe:
Contact hysteresis:
Process temp.:
Temp. comp.:
Ambient temp.:
Pressure:
Enclosure rating:
Encl. material:
Transducer type:
Transducer mat.:
Cable jacket mat.:
Cable type:
Cable length:
Process mount:
Mount gasket:
Classification:
Approval:
Compliance:
UG01: 1.5” to 4.9’ (3.8cm to 1.5m)
UG03: 4” to 9.8’ (10.1cm to 3m)
UG01: 0.125” (3mm)
UG03: ± 0.2% of range
UG01: 0.019” (0.5mm)
UG03: 0.039” (1mm)
UG01: 1.5” (3.8cm)
UG03: 4” (10.1cm)
2” (5cm)
WebCal® PC Windows® USB® 2.0
Non-volatile
14-28 VDC
0.5W
500 ohms @ 24 VDC
4-20mA, two-wire
4-20mA or 20-4mA
4mA, 20mA, 21mA, 22mA, hold last
(4) SPST relays
60 VA, 1A maximum
Open, closed, hold last
Selectable
F: -40º to 176º
C: -40º to 80º
Automatic
F: -31º to 140º
C: -35º to 60º
30 psi (2 bar)
Type 6P (IP68)
Polypropylene
Reflective
Polyvinylidene fluoride
Polyurethane
9-conductor, shielded
48” (1.2m)
-0001: 2” NPT
-0011: 2” G
-0001: N/a
-0011: Viton®
General purpose
UL 61010-1
CE, RoHS
Fittings
Configuration
The sensor is configured via our WebCal software
and one Fob USB adapter. WebCal is a PC utility
program that allows users to easily configure their
sensors, update firmware, save configurations and
print wiring schematics prior to installation. WebCal
is a free download from our website.
TANK ADAPTERS
LM52-2890
LM52-3890
2” NPT bulkhead fitting, PVC
3” NPT bulkhead fitting, PVC
REDUCER BUSHINGS
LM52-2400
LM52-2410
LM52-2800
LM52-2810
LM52-3800
LM52-3810
3” thread x 2” thread, NPT, PVC, schedule 40
3” socket x 2” thread, NPT, PVC, schedule 40
3” thread x 2” thread, NPT, PVC, schedule 80
3” socket x 2” thread, NPT, PVC, schedule 80
4” thread x 2” thread, NPT, PVC, schedule 80
4” socket x 2” thread, NPT, PVC, schedule 80
BRACKETS
LM50-1001
LM50-1061
2” NPT side mount bracket, PP
2” G side mount bracket, PP
Ordering
UG0 -00 1-4
SENSOR RANGE (1)
1 1.5m (4.9’)
3 3m (9.8’)
PROCESS MOUNT (2)
0 2” NPT
1 2” G
FOB USB ADAPTER (3)
0 Without Fob
1 With Fob
© 2019 Flowline | 10500 Humbolt Street, Los Alamitos, CA 90720 USA p 562.598.3015 f 562.431.8507 w flowline.com DS310125 REV A1
LI99-2001
NOTES
1)
If you want help in selecting a sensor for your application, please go to
our website and submit a Level Questionnaire. An engineer will review
your requirements and suggest a product solution via email.
2)
Install the sensor using Flowline installation fittings or equivalents.
3)
The sensor is configured via our WebCal software and one LI99-2001
Fob USB adapter. Sensors are offered with or without a Fob. Fobs are
universal and can be used to configure any WebCal compatible ultrasonic
or guided wave sensor. WebCal is a free download from our website.
Loading...