Flowline LU74, LU78 Operating Manual

EchoSwitch®
Ultrasonic Liquid Switch and Transmitter
LU74 & LU78 Series Quick Start
©2019 Flowline, Inc. All Rights Reserved Made in USA
Flowline, Inc. | 10500 Humbolt Street, Los Alamitos, CA 90720 p 562.598.3015 f 562.431.8507 w flowline.com QS300282 Rev B
WELCOME TO THE ECHOSWITCH® QUICK START
The EchoSwitch® Quick Start provides basic mounting, setup and use instructions for getting the EchoSwitch not addressed here, please refer to the EchoSwitch
®
up and running quickly. If you have a non-standard installation or setup requirement that is
®
Manual or other support documentation located at
flowline.com.
WE DO YOUR LEVEL BEST
Thank you for purchasing EchoSwitch®. The sensor provides integrated LCD and three push-button configuration. This quick start includes everything you’ll need to get the sensor up and running.
COMPONENTS
Depending on how the sensor part number that was shipped, EchoSwitch® comes with a Viton® gasket for installation and the Quick Start.
ECHOSWITCH
LU74-5004 & LU74-5064
®
Viton® gasket (2”)
P/N: 200129
LU78-5004 & LU78-5064
ENCLOSURE
While the switch housing is liquid-resistant the EchoSwitch® is not designed to be operational when immersed. It should be mounted in such a way that the enclosure and transducer do not come into contact with the application media under normal operational conditions. The enclosure has a flip cover with dual 1/2” NPT female conduit ports and an internal terminal strip for wiring. Before closing the enclosure, make sure that the enclosure gasket is properly seated, and that any conduit fittings, cable connectors or plugs are installed correctly and sealed. Note: If using the Flowline LM90-1001 (liquid tight fitting) on the ½” conduit, the cable minimum is 0.170” (4.3mm) and the maximum is 0.450” (11.4mm).
| 2 QS300282 Rev B
MOUNTING THE ECHOSWITCH®
The sensor should always be mounted perpendicular to the liquid surface using the provided Viton® mounting gasket. Insure that there are no restrictions or obstacles in the path of the acoustic signal. For further
®
mounting information, please refer to the EchoSwitch
manual at www.flowline.com.
Mounting with a Tank Adapter:
Select a tank adapter fitting, such as the LM52-2890.
Mounting in Riser:
As installations with tall, narrow risers can impede the acoustic signal. 2" diameter risers should be no taller than 4". Larger diameter risers should be no taller than 12". For best results, follow a 2:1 Height to Inner Diameter ratio (example: 8” High to 4” Inner Diameter).
Mounting in Side Mount Bracket:
Use Flowline's LM50-1001 side mount bracket.
LM50-1001 Shown
Note: The Side Mount Bracket (LM50 series) is not designed for use with stand pipes or as a method to secure stand pipes. There are too few threads to properly hold the sensor and the stand pipe.
QS300282 Rev B 3 |
IMP
O
12345
6
u
A
a
e
u
s
s
a
r
o
h
t
o
b
n
a
a
m
e
s
e
t
e
A
H
C
I
n
e
m
n
s
c
p
o
a
p
)
t
e
s
l
n
w
c
a
d
u
W
e
e
e
a
P
n
e
t
e
n
t
a
h
o
e
p
f
s
d
o
n
a
o
n
e
e
p
a
o
e
t
u
t
e
d
m
e
a
o
a
n
B
n
RTANT MO
UNTING GU
DELINES
) Never m
) Liquid s
) Mount a
) Never m
) Do not o
) Do not i
Mo
nting with
st
nd-pipe m
incr
ase perfor
pipe
is 3”. Larg
red
cer bushing
tank
adapter (S
sen
or (see exa
The
pipe length
to prevent
time equ
lization hol
sou
ces of subs
unt the se
ould never
least 3” fro
unt the se
struct the
stall in the
Stand-Pi
y be used t
ance in he
r diameter . Avoid the x T or S x S mple below
should run
foam from
within the
antial turbu
sor at an a
nter the de
the side
sor in a va
ensor’s be
enter of a
e:
dampen t
vy vapor.
ipes can b
use of multi
) and conn
.
he measur
ntering the
ensor’s de
ence which
gle.
ad band.
all.
uum.
m width.
ome top ta
rbulence, s
hen moun
used. Th
ple pipe fitti
ct the pipe
ment span pipe. Cut t
d band. L
might caus
k.
parate sur ing the sen pipe shoul
gs when p
o the inside
nd the bott
e bottom e cate the st
the liquid i
ace foam fr
or in a sta be attach ssible. An
slip and us
om of the pi
d of the pi
nd-pipe aw
n the pipe t
m the poin d-pipe, the d with a co
ideal moun
a reducer
pe should r
e at 45° an
y from pu
oscillate.
of measur
minimum di
pling or tan would be t bushing to
main subm
drill a 1/4”
p outlets a
ment or
meter of th
k adapter a
select a 3” ttach the
erged at all
pressure d/or other
e
d
3” x 2” Reduc
(T x T)
r Bushing
3” (S x Tank
T)
dapter
Vent
ole
3” PV
Pipe
Stand-
ipe Exam
le
Stand-Pip
Mounting
| 4