Flowline LR30 Specifications

®
EchoPulse
Pulse Radar Liquid Level Transmitter
LR30
Application
The general purpose 26 GHz. pulse radar transmitter provides continuous level measurement up to 98.4’ (30m) with a 4-20 mA signal output, and is configured via its remote push button display module. The non-contact liquid level sensor is intended for industrial wastewater, municipal storm or sewer lift station, reservoir, river, canal or open channel applications located below or above grade. Select this sensor for challenging process conditions that may include light surface foam or agitation, small trash or plant material, wind, condensation or vapor. Each comes with a 32.8’ (10m) cable, mounting bracket and display module. The sensor is designed for bracket mount installation suspended above the liquid level.
Features
Rugged IP68 sensor enclosure with 304 SS mounting bracket
Simple configuration via remote push button display module
26 GHz. pulse radar is unaffected by sump process conditions
Wall mounted display with windowed enclosure rated IP67
12” (30cm) dead band enables utilization of the entire sump
LCD displays level in feet or meters with percent of span bar
Optional display mode indicates the echo signal return curve
Auto-temperature compensation for accurate measurement
Self diagnostics with selectable fail-safe signal outputs
Recognition, storage and rejection of false echo signal returns
Success
Industrial and municipal pump lift stations collect and transfer wastewater into treatment. These waste receptacles are very dynamic environments that may contain dirt, grease, oil, agitation, sludge, foam, condensation, chemicals or vapor. Here, a LR30 is mounted to the top side wall of a 16’ sump. Its 26 GHz. pulse radar measurement is unaffected by the challenging process conditions.
© 2016 Flowline | 10500 Humbolt Street, Los Alamitos, CA 90720 USA p 562.598.3015 f 562.431.8507 w flowline.com DS301770 REV B1
®
2.95"
(75cm)
3.70"
(94mm)
1.57"
(40cm)
1/2" NPT
Adapter
0.75"
(19mm)
EchoPulse
Pulse Radar Liquid Level Transmitter
SENSOR
Range:
Frequency:
Accuracy:
Dead band:
Beam angle:
Supply voltage:
Max consumption:
Signal output:
Signal invert:
Signal fail-safe:
Process temp.:
Temp. comp.:
Pressure:
Enclosure rating:
Encl. material:
Cable type:
Cable length:
Cable jacket mat.:
Process mount:
DI SPL AY
Display type:
Display units:
Display bar:
Display graph:
Configuration:
Enclosure type:
Enclosure rating:
Encl. material:
Conduit entrance:
COMMON
Memory:
Storage temp.:
Classification:
Certification:
Compliance:
12” to 98.4’ (30cm to 30m)
26 GHz.
± 3mm
12” (30cm)
12º
16-26 VDC
22.5 mA
4-20 mA, two-wire
4-20 mA, 20-4 mA
3.9 mA, 20.5 mA, 22 mA
F: -40º to 212º
C: -40º to 100º
Automatic
Atmospheric
IP68
Nylon
6-conductor, shielded
32.8’ (10m)
PVC
304 SS bracket or 1” NPT
LCD, dot matrix
Feet and meters
Percent of span
Echo signal curve
Push button
Wall mount
IP67
Polycarbonate
(2) 1/2” NPT connectors
Non-volatile
F: -40º to 176º
C: -40º to 80º
General purpose
cTUVus, FCC
CE, RoHS
LR30
DimensionsSpecifications
1.54"
(39mm)
(280mm)
11.02"
10mm
Hex
(155.4mm)
6.12"
5.12"
1/2" NPT
4.88"
(130mm)
(124mm)
1”
NPT
1.18"
(30mm)
Wide
1.22"
(31mm)
3.04"
(77.2mm)
Display Front View
3.70"
(94mm)
EchoPulse™
3.19"
(81mm)
0.75"
(19mm)
12.34
SENSOR
PE
ft
EN
3.70"
(94mm)
0.91"
(23mm)
1/2" NPT
Display Side View
3.70"
(94mm)
0.75"
(19mm)
1/2" NPT
1.57"
(40cm)
2.95"
(75cm)
NOTES
If you want help in selecting a sensor for your application, please go to our
1)
website and submit a Level Questionnaire. An engineer will review your
requirements and suggest a product solution via email.
Includes the sensor, bracket, cable and display.
2)
Ordering
© 2016 Flowline | 10500 Humbolt Street, Los Alamitos, CA 90720 USA p 562.598.3015 f 562.431.8507 w flowline.com DS301770 REV B1
LR30-0010-10
(1) (2)