Flowline LR20 Specifications

®
EchoPulse
Pulse Radar Liquid Level Transmitter
LR20
Application
The general purpose 26 GHz. pulse radar transmitter provides continuous level measurement up to 65.6’ (20m) with a 4-20 mA signal output, and is configured via its integral push button display module. The non-contact liquid level sensor is intended for chemical storage or process applications in above or below grade tanks of any material. Select this sensor for challenging process conditions with corrosive media, light surface foam or agitation, higher temperature or pressure, condensation or vapor, and installation in a flange fitting. Typical applications include bulk storage and process tanks.
Features
316L antenna with PTFE inner shield for corrosive media
Simple configuration via integral push button display module
26 GHz. pulse radar is unaffected by vapor or condensation
12” (30cm) dead band enables utilization of the entire tank
LCD displays level in feet or meters with percent of span bar
Optional display mode indicates the echo signal return curve
Fail-safe diagnostics with selectable signal fail-safe outputs
Recognition, storage and rejection of false echo signal returns
Rugged IP67 aluminum enclosure with polycarbonate window
LR20-0310-30 Shown
Success
Hydrochloric acid is an inorganic acid that’s widely used in industrial and commercial applications. Both highly corrosive and vaporous, it’s difficult to measure. Here, a LR20 is flange mounted on a 18’ HCL storage tank at a steel fabrication company. Its 26 GHz. pulse radar measurement is un­affected by the extreme vapor, and the antenna’s PTFE inner shield, provides reliable corrosion resistance.
© 2018 Flowline | 10500 Humbolt Street, Los Alamitos, CA 90720 USA p 562.598.3015 f 562.431.8507 w flowline.com DS301750 REV B2
®
3.865"
EchoPulse
Pulse Radar Liquid Level Transmitter
LR20
Specifications
Range:
Frequency:
Accuracy:
Dead band:
Beam angle:
Configuration:
Memory:
Display type:
Display units:
Display bar:
Display graph:
Supply voltage:
Max. consumption:
Signal output:
Signal invert:
Signal fail-safe:
Process temp.:
Temp. comp.:
Storage temp.:
Pressure:
Enclosure rating:
Encl. material:
Encl. window mat.:
Conduit entrance:
Antenna material:
Process mount:
Classification:
Certification:
Compliance:
12” to 65.6’ (30cm to 20m)
26 GHz.
± 3mm
12” (30cm)
- 30: 12º
- 40: 8º
Push button
Non-volatile
LCD, dot matrix
Feet and meters
Percent of span
Echo signal curve
16-26 VDC
22.5 mA
4-20 mA, two-wire
4-20 mA, 20-4 mA
3.9 mA, 20.5 mA, 22 mA
F: -40º to 302º
C: -40º to 150º
Automatic
F: -40º to 176º
C: -40º to 80º
-14.5 to 72 psi (-1 to 5 bar)
IP67
Aluminum w/silicone gasket
Polycarbonate
(1) 1/2” NPT connector
(1) M20 x 1.5 plug
316L w/PTFE inner shield
- 30: 3” flange (ANSI)
- 40: 4” flange (ANSI)
General purpose
cTUVus
FCC
CE, CRN, RoHS
Dimensions
ANTENNA / FLANGE
-30
P/N
3” ANSI
A
7.5” (190.5mm)
B
0.88” (22.3mm)
C
6.5” (165mm)
D
Echo Signal Return Curve Shown
-40
4” ANSI
9.0” (228.6mm)
0.88” (22.3mm)
8.0” (203mm)
Compatible Products
LI23
DATA LOOP™
Level Indicator
(98.2mm)
(138.1mm)
5.44"
(78.0mm)
3.07"
D
B
DATAV IEW ™
Level Controller
LI55
½"
NPT
(83mm)
3.27"
A
C
Ordering
LR20-0310- 0
FLANGE SIZE (1)
3 3” ANSI
4 4” ANSI
© 2018 Flowline | 10500 Humbolt Street, Los Alamitos, CA 90720 USA p 562.598.3015 f 562.431.8507 w flowline.com DS301750 REV B2