Flotec FP0S4100X, FP0S3000X, FP0S1200X, FP0S2300X Owner's Manual

OWNER’S MANUAL
Submersible Waterfall/Utility Pumps
NOTICE D’UTILISATION
Pompes submersibles tout usage et pour chute d’eau
MANUAL DEL USUARIO
Installation/Operation/Parts
For further operating, installation, or maintenance assistance:
Call 1-800-365-6832
English . . . . . . . . . . . . . . Pages 2-6
Installation/Fonctionnement/Pièces
Pour plus de renseignements concernant l’utilisation, l’installation ou l’entretien,
Composer le
1 (800) 365-6832
Français . . . . . . . . . . . Pages 7-11
Instalación/Operación/Piezas
Para mayor información sobre el funcionamiento, instalación o mantenimiento de la bomba:
Llame al 1-800-365-6832
Español . . . . . . . . . .Paginas 12-16
FP514/253P4180 (Rev. 1/21/05)
FP0S4100X FP0S1200X
FP0S2300X FP0S3000X
P.O. Box 342, Delavan, WI 53115
Phone: 1-800-365-6832 Fax: 1-800-526-3757 E-Mail: info@flotecwater.com Web Site: http://www.flotecwater.com
®
3384 0399 ASB UPD
Safety 2
For parts or assistance, call Flotec Customer Service at 1-800-365-6832
READ AND FOLLOW
SAFETY INSTRUCTIONS!
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury.
warns about hazards that will cause serious
personal injury, death or major property damage if ignored.
warns about hazards that can cause serious
personal injury, death or major property damage if ignored.
warns about hazards that will or can cause
minor personal injury or property damage if ignored. The label NOTICE indicates special instructions which
are important but not related to hazards.
GENERAL SAFETY
Carefully read and follow all safety instructions in this manual and on pump.
Keep safety labels in good condition. Replace missing or damaged safety labels.
To avoid serious injury and/or property damage, read and follow these rules and instructions carefully.
Hazardous voltage. Can shock, burn or
cause death. To reduce the risk of electric shock, use
only on portable self-contained fountains no larger than 5 feet in any dimension.
1. Pump is designed for use with clean, cold, fresh
water. Do not use to pump any flammable liquid.
2. Do not lift pump by power cord at any time.
Attempting to lift or support the pump by the power cord can damage the cord and cord connections, and will void warranty. Always lift the pump by the lifting handle.
3. Meet National Electrical Code, Canadian Electrical
Code, and local codes for all wiring. The National Electric Code requires installation of a ground fault circuit interrupter (GFCI) in the branch circuit sup­plying fountain pumps and other pond equipment. Purchase a GFI at your local electrical supply dealer.
4. Installation must comply with all local codes per-
taining to outdoor ponds/waterfall/fountains.
5. Know the pump application, limitations, and poten-
tial hazards.
6. Disconnect the power before servicing.
7. Release all pressure within the system before servic­ing any component.
8. Drain all water from the system before servicing.
9. Secure the discharge line before starting pump. An unsecured discharge line will whip, possibly causing personal injury and/or property damage.
10. Check hoses for weak or worn condition before each use, making certain that all connections are secure.
11. Periodically inspect the pump and system compo­nents. Keep the screen free of debris and foreign objects. Perform routine maintenance as required.
12. Personal Safety: a. Wear safety glasses at all times when working with
pumps.
b. Keep work area clean, uncluttered and properly
lighted – replace all unused tools and equipment. c. Keep visitors at a safe distance from work area. d. Make workshop child-proof – with padlocks, mas-
ter switches, and by removing starter keys.
13. This equipment is only for use on 115 volt (single phase) and is equipped with an approved 3-conduc­tor cord and 3-prong, grounding-type plug.
Hazardous voltage. Can shock, burn or
cause death. T
o reduce risk of electric shock, pull plug before servicing. This pump has not been investigated for use in swimming pool areas. Pump is supplied with a grounding conductor and grounding-type attachment plug. Be sure it is connected only to an individual branch circuit with a properly grounded grounding-type receptacle. Where a 2-prong wall receptacle is encountered, it must be replaced with a properly grounded 3-prong receptacle installed in accordance with codes and ordinances that apply.
14. Make certain power source conforms to requirements
of your equipment.
15. Protect the electrical cord from sharp objects, hot sur-
faces, oil, and chemicals. Avoid kinking cord. Replace or repair damaged or worn cords immediately.
16. Do not touch an operating motor. Modern motors are
designed to operate at high temperatures.
17. Do not handle pump or pump motor with wet hands
or when standing on wet or damp surface, or in water.
Ta b le of Contents 3
Thank you for purchasing a top quality, factory tested pump.
Page
General Safety .....................................................................................................2
Warranty..............................................................................................................3
Installation ........................................................................................................4,5
Maintenance........................................................................................................6
Troubleshooting ...................................................................................................6
AT TACH ORIGINAL RECEIPT HERE FOR WARRANTY CONSIDERATION.
FLOTEC warrants to the original consumer purchaser (“Purchaser”) of its prod­ucts that they are free from defects in material or workmanship.
If within twelve (12) months from the date of the original consumer purchase any such product shall prove to be defective, it shall be repaired or replaced at FLOTEC’s option, subject to the terms and conditions set forth below. Your orig­inal receipt of purchase is required to determine warranty eligibility.
Exceptions to the Twelve (12) Month Warranty
Ninety (90) Day Warranty:
If within ninety (90) days from original consumer purchase any Drill Pump, Pitcher Pump, or In-Line Water Filter Cartridge shall prove to be defective, it shall be replaced, subject to the terms set forth below.
Two (2) Year Warranty:
If within two (2) years from original consumer purchase any 1/3 HP Submersible Sump Pump shall prove to be defective, it shall be repaired or replaced at FLOTEC’s option, subject to the terms and conditions set forth below.
Three (3) Year Warranty:
If within three (3) years from original consumer purchase any 4” Submersible Well Pump, or 1/2 HP Submersible Sump Pump, shall prove to be defective, it shall be repaired or replaced at FLOTEC’s option, subject to the terms and con­ditions set forth below.
Four (4) Year Warranty:
If within four (4) years from original consumer purchase any FLOODMATE 7000
TM
Submersible Sump Pump shall prove to be defective, it shall be repaired or replaced at FLOTEC’s option, subject to the terms and conditions set forth below.
Five (5) Year Warranty:
If within five (5) years from original consumer purchase any Pre-Charge water system tank shall prove to be defective, it shall be repaired or replaced at FLOTEC’s option, subject to the terms and conditions set forth below.
General Terms and Conditions
Purchaser must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty shall not apply to acts of God, nor shall it apply to products which, in the sole judgement of FLOTEC, have been sub­ject to negligence, abuse, accident, misapplication, tampering, alteration; nor due to improper installation, operation, maintenance or storage; nor to other than normal application, use or service, including but not limited to, opera­tional failures caused by corrosion, rust or other foreign materials in the system, or operation at pressures in excess of recommended maximums.
Requests for service under this warranty shall be made by returning the defec­tive product to the Retail outlet or to FLOTEC as soon as possible after the dis­covery of any alleged defect. FLOTEC will subsequently take corrective action as promptly as reasonably possible. No requests for service under this warran­ty will be accepted if received more than 30 days after the term of the warran­ty.
This warranty sets forth FLOTEC’s sole obligation and purchaser’s exclusive remedy for defective products.
FLOTEC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICABLE EXPRESS WARRANTIES PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or conse­quential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
Flotec Limited Warranty
FLOTEC • P.O. Box 342 • Delavan, WI U.S.A. 53115
Phone: 1-800-365-6832 • Fax: 1-800-526-3757
E-Mail: info@flotecwater.com • Web Site: http://www.flotecwater.com
Installation 4
DESCRIPTION
These submersible pumps are designed for use in water­fall/ fountain applications or as a utility pump. The units are equipped with a 3-prong grounding-type power cord. Ball bearings on motor shafts never need lubrication. Automatic reset thermal protection.
Pump water only with this pump.
SPECIFICATIONS
Power supply required..................................115V, 60 HZ.
Motor duty .......................................................continuous
Liquid Temp. Range .....................32°F to 100°F (0°-38°C)
Individual Branch Circuit
Requirement (minimum) ......................................15 Amps
Discharge Fittings:
...........................1/2”, 3/4”, and 1” Barbed Hose Adapter
.................................................1-1/4” x 1” FNPT Reducer
........................................................Garden Hose Adapter
NOTICE: Not designed for applications involving salt water or brine! Use with salt water or brine will void warranty.
ELECTRICAL SPECIFICATIONS
INSTALLATION
See Figure 1 for typical installation connections to pump (NOTE: Fountain accessories not included with pump).
1. Install the pump on a hard level surface. Make sure that the pump cannot pick up rocks, mud and debris, etc. If neccesary, put a block under the pump to raise it slightly. If used with a fountain jet, position the pump so that the fountain jet is above the surface of the water.
2. Protect the power cord from damage. Uncovered cords should be routinely inspected for damage or deterioration. DO NOT operate the pump if the cord is damaged.
3. If used in a garden pond, adjust the diverter valve to control the fountain spray height and flow over the waterfall. Do not restrict pump suction to adjust flows. Restrictng the suction will starve the pump for water and can damage the pump.
4. If the pump is connected to a pond filter, adjust the diverter valve to provide adequate flow to the filter. Refer to the filter instruction manual to determine flow requirements of filter.
For parts or assistance, call Flotec Customer Service at 1-800-365-6832
GPH (LPH) AT TOTAL FEET (M) No Flow
Motor 1 5 10 15 20 25 At Height
Model HP (.3 M) (1.5 M) (3 M) (4.6 M) (6.1 M) (7.6 M) Shown Below
FP0S1200X 1/6 1,200 (4,542) 1,000 (3,785) 675 (2,555) 400 (1,514) 20’ (6.1 M) FP0S2300X 3/10 2,300 (8,858) 1,975 (7,476) 1,425 (5,394) 850 (3,218) 300 (1,136) 22’ (6.7 M) FP0S3000X 4/10 3,000 (11,356) 2,500 (9,464) 1,900 (7,192) 1,320 (4,997) 750 (2,839) 25’ (7.6 M) FP0S4100X 1/2 4,100 (15,520) 3,600 (13,627) 3,000 (11,356) 2,400 (9,085) 1,625 (6,151) 920 (3,483) 30’ (9.1 M)
PERFORMANCE
Motor Minimum Pumps
Motor Full Load Circuit Down
Model H.P. Amps Req. (Amps) To
FP0S1200X 1/6 1.5 15 7/16” (11mm) FP0S2300X 3/10 2.6 15 7/16” (11mm) FP0S3000X 4/10 3.0 15 7/16” (11mm) FP0S4100X 1/2 7.2 15 1-3/8” (35mm)
Figure 1: Typical Garden Pond and Waterfall Installation.
Use foliage to cover tubing to waterfall
Diverter valve
Raise the pump off of the bottom of the pond
Plastic tubing to waterfall
3388 0399
Power cord
GFCI outlet
Landscaping rocks