Flotec FP0S4100X, FP0S1200X, FP0S2300X, FP0S3000X Owner's Manual

OWNER’S MANUAL
Submersible Waterfall / Utility Pumps
293 Wright Street, Delavan, WI 53115
Phone: 800-365-6832 Fax: 800-526-3757 www.flotecwater.com
NOTICE D’UTILISATION
Pompes submersibles tout usage et pour chute d’eau
MANUAL DEL USUARIO
Installation/Operation/Parts
For further operating, installation, or maintenance assistance:
Call 800-365-6832
English............Pages 2-6
© 2012 FP514 / 253P4180 (07/19/12)
FP0S4100X FP0S1200X
3384 0399 ASB UPD
FP0S2300X FP0S3000X
Installation/Fonctionnement/Pièces
Pour plus de renseignements concernant l’utilisation, l’installation ou l’entretien,
Composer le (800) 365-6832
Français..........Pages 7-11
Instalación/Operación/Piezas
Para mayor información sobre el funcionamiento, instalación o mantenimiento de la bomba:
Llame al 800-365-6832
Español ....... Paginas 12-16
Safety 2
Important Safety Instructions
SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during installation, operation, and maintenance of the product.
This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury!
indicates a hazard which, if not avoided, will
result in death or serious injury.
indicates a hazard which, if not avoided,
could result in death or serious injury.
indicates a hazard which, if not avoided,
could result in minor or moderate injury. NOTICE addresses practices not related to
personalinjury.
Carefully read and follow all safety instructions in this manual and on pump.
Keep safety labels in good condition. Replace missing or damaged safety labels.
California Proposition 65 Warning
This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
General Safety
Risk of electric shock. Can shock, burn or kill. To reduce the risk of electric shock, use only on portable self-contained fountains no larger than 5 feet in any dimension.
1. Pump is designed for use with clean, cold, fresh
water. Do not use to pump any flammable liquid.
2. Do not lift pump by power cord at any time.
Attempting to lift or support the pump by the power cord can damage the cord and cord connections, and will void warranty. Always lift the pump by the lifting handle.
3. Meet National Electri cal Code, Canadian Elec-
tri cal Code, and local codes for all wiring. The National Electric Code requires installation of a ground fault circuit interrupter (GFCI) in the branch circuit supplying fountain pumps and other pond equipment. Purchase a GFI at your local electrical supply dealer.
4. Installation must comply with all local codes
pertaining to outdoor ponds/waterfall/fountains.
5. Know the pump application, limitations, and
potential hazards.
6. Disconnect the power before servicing.
7. Release all pressure within the system before servicing any component.
8. Drain all water from the system before servicing.
9. Secure the discharge line before starting pump. An unsecured discharge line will whip, possibly causing personal injury and/or property damage.
10. Check hoses for weak or worn condition before each use, making certain that all connections are secure.
11. Periodically inspect the pump and system components. Keep the screen free of debris and foreign objects. Perform routine maintenance asrequired.
12. Personal Safety: a. Wear safety glasses at all times when working
with pumps.
b. Keep work area clean, uncluttered and
properly lighted – replace all unused tools
andequipment. c. Keep visitors at a safe distance from work area. d. Make workshop child-proof – with padlocks,
master switches, and by removing starter keys.
13. This equipment is only for use on 115 volt
(single phase) and is equipped with an approved 3-conductor cord and 3-prong, grounding-type plug.
burn or kill. To reduce risk of electric shock, pull plug before servicing. This pump has not been investigated for use in swimming pool areas. Pump is supplied with a grounding conductor and grounding­type attachment plug. Be sure it is connected only to an individual branch circuit with a properly grounded grounding-type receptacle.
Where a 2-prong wall receptacle is encountered, it
must be replaced with a properly grounded 3-prong receptacle installed in accordance with codes and ordinances that apply.
14. Make certain power source conforms to requirements of your equipment.
15. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking cord. Replace or repair damaged or worn cords immediately.
16. Do not touch an operating motor. Modern motors are designed to operate at high temperatures.
17. Do not handle pump or pump motor with wet hands or when standing on wet or damp surface, or inwater.
Risk of electric shock. Can shock,
For parts or assistance, call Flotec Customer Service at 800-365-6832.